Cargando…
Early results of revision acetabular cup using antiprotrusio reconstruction rings and allografts
BACKGROUND: Hip arthroplasty is one of the most frequently performed orthopedic procedures with high scores of success while its most common complication is aseptic loosening of the acetabular component, which may result from host bone loss or even from pelvis discontinuity. The purpose of the study...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4443414/ https://www.ncbi.nlm.nih.gov/pubmed/26015632 http://dx.doi.org/10.4103/0019-5413.156205 |
_version_ | 1782372984582832128 |
---|---|
author | Kmieć, Krzysztof Dorman, Tomasz Andrzej, Grzegorzewski Synder, Marek Kozłowski, Piotr Sibiński, Marcin |
author_facet | Kmieć, Krzysztof Dorman, Tomasz Andrzej, Grzegorzewski Synder, Marek Kozłowski, Piotr Sibiński, Marcin |
author_sort | Kmieć, Krzysztof |
collection | PubMed |
description | BACKGROUND: Hip arthroplasty is one of the most frequently performed orthopedic procedures with high scores of success while its most common complication is aseptic loosening of the acetabular component, which may result from host bone loss or even from pelvis discontinuity. The purpose of the study was to evaluate results in patients after revision acetabular arthroplasty with reconstruction rings and allografts. MATERIALS AND METHODS: Retrospective data was collected from 69 revisions of acetabular components, performed in a group of 69 treated patients (the mean age 65.1 years). Before surgery, the patients had bone defects of type IIb (n = 5), IIc (n = 20), IIIa (n = 27) or IIIb (n = 17), according to Paprosky et al. RESULTS: The mean followup period of the patients was 7.2 years (range 3-19 years). A Kaplan–Meier analysis showed that a 3- and 10 year survival rate was 92.8% and 84.8% respectively, using further revision for any reason of the acetabular device as an end point. Eight patients revealed implant related complications. Four patients presented with ring loosening, one with a loose acetabular polyethylene cup, two hips demonstrated recurrent dislocations and one patient was with deep infection. Regarding the remaining 61 patients without re-revision surgery, the mean Harris hip score improved from 30.5 to 73.8 points. CONCLUSION: A modified, antiprotrusion cage provides an acceptable survival rate and radiological results, but complications could still be expected. It seems that the observed massive bone loss with pelvic discontinuity and an insufficient fixation of the cage to the ischium may result in implant loosening. Stable fixation of the ischial ring flange with screws is an essential condition to expect a good outcome. |
format | Online Article Text |
id | pubmed-4443414 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-44434142015-05-26 Early results of revision acetabular cup using antiprotrusio reconstruction rings and allografts Kmieć, Krzysztof Dorman, Tomasz Andrzej, Grzegorzewski Synder, Marek Kozłowski, Piotr Sibiński, Marcin Indian J Orthop Original Article BACKGROUND: Hip arthroplasty is one of the most frequently performed orthopedic procedures with high scores of success while its most common complication is aseptic loosening of the acetabular component, which may result from host bone loss or even from pelvis discontinuity. The purpose of the study was to evaluate results in patients after revision acetabular arthroplasty with reconstruction rings and allografts. MATERIALS AND METHODS: Retrospective data was collected from 69 revisions of acetabular components, performed in a group of 69 treated patients (the mean age 65.1 years). Before surgery, the patients had bone defects of type IIb (n = 5), IIc (n = 20), IIIa (n = 27) or IIIb (n = 17), according to Paprosky et al. RESULTS: The mean followup period of the patients was 7.2 years (range 3-19 years). A Kaplan–Meier analysis showed that a 3- and 10 year survival rate was 92.8% and 84.8% respectively, using further revision for any reason of the acetabular device as an end point. Eight patients revealed implant related complications. Four patients presented with ring loosening, one with a loose acetabular polyethylene cup, two hips demonstrated recurrent dislocations and one patient was with deep infection. Regarding the remaining 61 patients without re-revision surgery, the mean Harris hip score improved from 30.5 to 73.8 points. CONCLUSION: A modified, antiprotrusion cage provides an acceptable survival rate and radiological results, but complications could still be expected. It seems that the observed massive bone loss with pelvic discontinuity and an insufficient fixation of the cage to the ischium may result in implant loosening. Stable fixation of the ischial ring flange with screws is an essential condition to expect a good outcome. Medknow Publications & Media Pvt Ltd 2015 /pmc/articles/PMC4443414/ /pubmed/26015632 http://dx.doi.org/10.4103/0019-5413.156205 Text en Copyright: © Indian Journal of Orthopaedics http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Kmieć, Krzysztof Dorman, Tomasz Andrzej, Grzegorzewski Synder, Marek Kozłowski, Piotr Sibiński, Marcin Early results of revision acetabular cup using antiprotrusio reconstruction rings and allografts |
title | Early results of revision acetabular cup using antiprotrusio reconstruction rings and allografts |
title_full | Early results of revision acetabular cup using antiprotrusio reconstruction rings and allografts |
title_fullStr | Early results of revision acetabular cup using antiprotrusio reconstruction rings and allografts |
title_full_unstemmed | Early results of revision acetabular cup using antiprotrusio reconstruction rings and allografts |
title_short | Early results of revision acetabular cup using antiprotrusio reconstruction rings and allografts |
title_sort | early results of revision acetabular cup using antiprotrusio reconstruction rings and allografts |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4443414/ https://www.ncbi.nlm.nih.gov/pubmed/26015632 http://dx.doi.org/10.4103/0019-5413.156205 |
work_keys_str_mv | AT kmieckrzysztof earlyresultsofrevisionacetabularcupusingantiprotrusioreconstructionringsandallografts AT dormantomasz earlyresultsofrevisionacetabularcupusingantiprotrusioreconstructionringsandallografts AT andrzejgrzegorzewski earlyresultsofrevisionacetabularcupusingantiprotrusioreconstructionringsandallografts AT syndermarek earlyresultsofrevisionacetabularcupusingantiprotrusioreconstructionringsandallografts AT kozłowskipiotr earlyresultsofrevisionacetabularcupusingantiprotrusioreconstructionringsandallografts AT sibinskimarcin earlyresultsofrevisionacetabularcupusingantiprotrusioreconstructionringsandallografts |