Cargando…

Good sensitivity and specificity of ultrasound for detecting pseudotumors in 83 failed metal-on-metal hip replacements

BACKGROUND AND PURPOSE: Ultrasound is used for imaging of pseudotumors associated with metal-on-metal (MoM) hips. Ultrasound has been compared with magnetic resonance imaging, but to date there have been no studies comparing ultrasound findings and revision findings. METHODS: We evaluated the sensit...

Descripción completa

Detalles Bibliográficos
Autores principales: Lainiala, Olli, Elo, Petra, Reito, Aleksi, Pajamäki, Jorma, Puolakka, Timo, Eskelinen, Antti
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Informa Healthcare 2015
Materias:
Hip
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4443452/
https://www.ncbi.nlm.nih.gov/pubmed/25582840
http://dx.doi.org/10.3109/17453674.2014.1001970
_version_ 1782372990491557888
author Lainiala, Olli
Elo, Petra
Reito, Aleksi
Pajamäki, Jorma
Puolakka, Timo
Eskelinen, Antti
author_facet Lainiala, Olli
Elo, Petra
Reito, Aleksi
Pajamäki, Jorma
Puolakka, Timo
Eskelinen, Antti
author_sort Lainiala, Olli
collection PubMed
description BACKGROUND AND PURPOSE: Ultrasound is used for imaging of pseudotumors associated with metal-on-metal (MoM) hips. Ultrasound has been compared with magnetic resonance imaging, but to date there have been no studies comparing ultrasound findings and revision findings. METHODS: We evaluated the sensitivity and specificity of preoperative ultrasound for detecting pseudotumors in 82 patients with MoM hip replacement (82 hips). Ultrasound examinations were performed by 1 of 3 musculoskeletal radiologists, and pseudotumors seen by ultrasound were retrospectively classified as fluid-filled, mixed-type, or solid. Findings at revision surgery were retrieved from surgical notes and graded according to the same system as used for ultrasound findings. RESULTS: Ultrasound had a sensitivity of 83% (95% CI: 63–93) and a specificity of 92% (CI: 82–96) for detecting trochanteric region pseudotumors, and a sensitivity of 79% (CI: 62–89) and a specificity of 94% (CI: 83–98) for detecting iliopsoas-region pseudotumors. Type misclassification of pseudotumors found at revision occurred in 8 of 23 hips in the trochanteric region and in 19 of 33 hips in the iliopsoas region. INTERPRETATION: Despite the discrepancy in type classification between ultrasound and revision findings, the presence of pseudotumors was predicted well with ultrasound in our cohort of failed MoM hip replacements.
format Online
Article
Text
id pubmed-4443452
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Informa Healthcare
record_format MEDLINE/PubMed
spelling pubmed-44434522015-06-08 Good sensitivity and specificity of ultrasound for detecting pseudotumors in 83 failed metal-on-metal hip replacements Lainiala, Olli Elo, Petra Reito, Aleksi Pajamäki, Jorma Puolakka, Timo Eskelinen, Antti Acta Orthop Hip BACKGROUND AND PURPOSE: Ultrasound is used for imaging of pseudotumors associated with metal-on-metal (MoM) hips. Ultrasound has been compared with magnetic resonance imaging, but to date there have been no studies comparing ultrasound findings and revision findings. METHODS: We evaluated the sensitivity and specificity of preoperative ultrasound for detecting pseudotumors in 82 patients with MoM hip replacement (82 hips). Ultrasound examinations were performed by 1 of 3 musculoskeletal radiologists, and pseudotumors seen by ultrasound were retrospectively classified as fluid-filled, mixed-type, or solid. Findings at revision surgery were retrieved from surgical notes and graded according to the same system as used for ultrasound findings. RESULTS: Ultrasound had a sensitivity of 83% (95% CI: 63–93) and a specificity of 92% (CI: 82–96) for detecting trochanteric region pseudotumors, and a sensitivity of 79% (CI: 62–89) and a specificity of 94% (CI: 83–98) for detecting iliopsoas-region pseudotumors. Type misclassification of pseudotumors found at revision occurred in 8 of 23 hips in the trochanteric region and in 19 of 33 hips in the iliopsoas region. INTERPRETATION: Despite the discrepancy in type classification between ultrasound and revision findings, the presence of pseudotumors was predicted well with ultrasound in our cohort of failed MoM hip replacements. Informa Healthcare 2015-06 2015-05 /pmc/articles/PMC4443452/ /pubmed/25582840 http://dx.doi.org/10.3109/17453674.2014.1001970 Text en Copyright: © Nordic Orthopaedic Federation http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the CC-BY-NC-ND 3.0 License which permits users to download and share the article for non-commercial purposes, so long as the article is reproduced in the whole without changes, and provided the original source is credited.
spellingShingle Hip
Lainiala, Olli
Elo, Petra
Reito, Aleksi
Pajamäki, Jorma
Puolakka, Timo
Eskelinen, Antti
Good sensitivity and specificity of ultrasound for detecting pseudotumors in 83 failed metal-on-metal hip replacements
title Good sensitivity and specificity of ultrasound for detecting pseudotumors in 83 failed metal-on-metal hip replacements
title_full Good sensitivity and specificity of ultrasound for detecting pseudotumors in 83 failed metal-on-metal hip replacements
title_fullStr Good sensitivity and specificity of ultrasound for detecting pseudotumors in 83 failed metal-on-metal hip replacements
title_full_unstemmed Good sensitivity and specificity of ultrasound for detecting pseudotumors in 83 failed metal-on-metal hip replacements
title_short Good sensitivity and specificity of ultrasound for detecting pseudotumors in 83 failed metal-on-metal hip replacements
title_sort good sensitivity and specificity of ultrasound for detecting pseudotumors in 83 failed metal-on-metal hip replacements
topic Hip
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4443452/
https://www.ncbi.nlm.nih.gov/pubmed/25582840
http://dx.doi.org/10.3109/17453674.2014.1001970
work_keys_str_mv AT lainialaolli goodsensitivityandspecificityofultrasoundfordetectingpseudotumorsin83failedmetalonmetalhipreplacements
AT elopetra goodsensitivityandspecificityofultrasoundfordetectingpseudotumorsin83failedmetalonmetalhipreplacements
AT reitoaleksi goodsensitivityandspecificityofultrasoundfordetectingpseudotumorsin83failedmetalonmetalhipreplacements
AT pajamakijorma goodsensitivityandspecificityofultrasoundfordetectingpseudotumorsin83failedmetalonmetalhipreplacements
AT puolakkatimo goodsensitivityandspecificityofultrasoundfordetectingpseudotumorsin83failedmetalonmetalhipreplacements
AT eskelinenantti goodsensitivityandspecificityofultrasoundfordetectingpseudotumorsin83failedmetalonmetalhipreplacements