Cargando…
Good sensitivity and specificity of ultrasound for detecting pseudotumors in 83 failed metal-on-metal hip replacements
BACKGROUND AND PURPOSE: Ultrasound is used for imaging of pseudotumors associated with metal-on-metal (MoM) hips. Ultrasound has been compared with magnetic resonance imaging, but to date there have been no studies comparing ultrasound findings and revision findings. METHODS: We evaluated the sensit...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Informa Healthcare
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4443452/ https://www.ncbi.nlm.nih.gov/pubmed/25582840 http://dx.doi.org/10.3109/17453674.2014.1001970 |
_version_ | 1782372990491557888 |
---|---|
author | Lainiala, Olli Elo, Petra Reito, Aleksi Pajamäki, Jorma Puolakka, Timo Eskelinen, Antti |
author_facet | Lainiala, Olli Elo, Petra Reito, Aleksi Pajamäki, Jorma Puolakka, Timo Eskelinen, Antti |
author_sort | Lainiala, Olli |
collection | PubMed |
description | BACKGROUND AND PURPOSE: Ultrasound is used for imaging of pseudotumors associated with metal-on-metal (MoM) hips. Ultrasound has been compared with magnetic resonance imaging, but to date there have been no studies comparing ultrasound findings and revision findings. METHODS: We evaluated the sensitivity and specificity of preoperative ultrasound for detecting pseudotumors in 82 patients with MoM hip replacement (82 hips). Ultrasound examinations were performed by 1 of 3 musculoskeletal radiologists, and pseudotumors seen by ultrasound were retrospectively classified as fluid-filled, mixed-type, or solid. Findings at revision surgery were retrieved from surgical notes and graded according to the same system as used for ultrasound findings. RESULTS: Ultrasound had a sensitivity of 83% (95% CI: 63–93) and a specificity of 92% (CI: 82–96) for detecting trochanteric region pseudotumors, and a sensitivity of 79% (CI: 62–89) and a specificity of 94% (CI: 83–98) for detecting iliopsoas-region pseudotumors. Type misclassification of pseudotumors found at revision occurred in 8 of 23 hips in the trochanteric region and in 19 of 33 hips in the iliopsoas region. INTERPRETATION: Despite the discrepancy in type classification between ultrasound and revision findings, the presence of pseudotumors was predicted well with ultrasound in our cohort of failed MoM hip replacements. |
format | Online Article Text |
id | pubmed-4443452 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Informa Healthcare |
record_format | MEDLINE/PubMed |
spelling | pubmed-44434522015-06-08 Good sensitivity and specificity of ultrasound for detecting pseudotumors in 83 failed metal-on-metal hip replacements Lainiala, Olli Elo, Petra Reito, Aleksi Pajamäki, Jorma Puolakka, Timo Eskelinen, Antti Acta Orthop Hip BACKGROUND AND PURPOSE: Ultrasound is used for imaging of pseudotumors associated with metal-on-metal (MoM) hips. Ultrasound has been compared with magnetic resonance imaging, but to date there have been no studies comparing ultrasound findings and revision findings. METHODS: We evaluated the sensitivity and specificity of preoperative ultrasound for detecting pseudotumors in 82 patients with MoM hip replacement (82 hips). Ultrasound examinations were performed by 1 of 3 musculoskeletal radiologists, and pseudotumors seen by ultrasound were retrospectively classified as fluid-filled, mixed-type, or solid. Findings at revision surgery were retrieved from surgical notes and graded according to the same system as used for ultrasound findings. RESULTS: Ultrasound had a sensitivity of 83% (95% CI: 63–93) and a specificity of 92% (CI: 82–96) for detecting trochanteric region pseudotumors, and a sensitivity of 79% (CI: 62–89) and a specificity of 94% (CI: 83–98) for detecting iliopsoas-region pseudotumors. Type misclassification of pseudotumors found at revision occurred in 8 of 23 hips in the trochanteric region and in 19 of 33 hips in the iliopsoas region. INTERPRETATION: Despite the discrepancy in type classification between ultrasound and revision findings, the presence of pseudotumors was predicted well with ultrasound in our cohort of failed MoM hip replacements. Informa Healthcare 2015-06 2015-05 /pmc/articles/PMC4443452/ /pubmed/25582840 http://dx.doi.org/10.3109/17453674.2014.1001970 Text en Copyright: © Nordic Orthopaedic Federation http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the CC-BY-NC-ND 3.0 License which permits users to download and share the article for non-commercial purposes, so long as the article is reproduced in the whole without changes, and provided the original source is credited. |
spellingShingle | Hip Lainiala, Olli Elo, Petra Reito, Aleksi Pajamäki, Jorma Puolakka, Timo Eskelinen, Antti Good sensitivity and specificity of ultrasound for detecting pseudotumors in 83 failed metal-on-metal hip replacements |
title | Good sensitivity and specificity of ultrasound for detecting pseudotumors in 83
failed metal-on-metal hip replacements |
title_full | Good sensitivity and specificity of ultrasound for detecting pseudotumors in 83
failed metal-on-metal hip replacements |
title_fullStr | Good sensitivity and specificity of ultrasound for detecting pseudotumors in 83
failed metal-on-metal hip replacements |
title_full_unstemmed | Good sensitivity and specificity of ultrasound for detecting pseudotumors in 83
failed metal-on-metal hip replacements |
title_short | Good sensitivity and specificity of ultrasound for detecting pseudotumors in 83
failed metal-on-metal hip replacements |
title_sort | good sensitivity and specificity of ultrasound for detecting pseudotumors in 83
failed metal-on-metal hip replacements |
topic | Hip |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4443452/ https://www.ncbi.nlm.nih.gov/pubmed/25582840 http://dx.doi.org/10.3109/17453674.2014.1001970 |
work_keys_str_mv | AT lainialaolli goodsensitivityandspecificityofultrasoundfordetectingpseudotumorsin83failedmetalonmetalhipreplacements AT elopetra goodsensitivityandspecificityofultrasoundfordetectingpseudotumorsin83failedmetalonmetalhipreplacements AT reitoaleksi goodsensitivityandspecificityofultrasoundfordetectingpseudotumorsin83failedmetalonmetalhipreplacements AT pajamakijorma goodsensitivityandspecificityofultrasoundfordetectingpseudotumorsin83failedmetalonmetalhipreplacements AT puolakkatimo goodsensitivityandspecificityofultrasoundfordetectingpseudotumorsin83failedmetalonmetalhipreplacements AT eskelinenantti goodsensitivityandspecificityofultrasoundfordetectingpseudotumorsin83failedmetalonmetalhipreplacements |