Cargando…

Tandem-ring dwell time ratio in Nigeria: dose comparisons of two loading patterns in standard high-dose-rate brachytherapy planning for cervical cancer

PURPOSE: In high-dose-rate (HDR) brachytherapy (BT), the source dwell times and dwell positions are essential treatment planning parameters. An optimal choice of these factors is fundamental to obtain the desired target coverage with the lowest achievable dose to the organs at risk (OARs). This stud...

Descripción completa

Detalles Bibliográficos
Autores principales: Ibhade, Obed Rachel, Oyeyemi, Oyekunle Emmanuel, Idayat, Akinlade Bidemi, Atara I., Ntekim
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4444453/
https://www.ncbi.nlm.nih.gov/pubmed/26034498
http://dx.doi.org/10.5114/jcb.2015.50660
_version_ 1782373149485039616
author Ibhade, Obed Rachel
Oyeyemi, Oyekunle Emmanuel
Idayat, Akinlade Bidemi
Atara I., Ntekim
author_facet Ibhade, Obed Rachel
Oyeyemi, Oyekunle Emmanuel
Idayat, Akinlade Bidemi
Atara I., Ntekim
author_sort Ibhade, Obed Rachel
collection PubMed
description PURPOSE: In high-dose-rate (HDR) brachytherapy (BT), the source dwell times and dwell positions are essential treatment planning parameters. An optimal choice of these factors is fundamental to obtain the desired target coverage with the lowest achievable dose to the organs at risk (OARs). This study evaluates relevant dose parameters in cervix brachytherapy in order to assess existing tandem-ring dwell time ratio used at the first HDR BT center in Nigeria, and compare it with an alternative source loading pattern. MATERIAL AND METHODS: At the Radiotherapy Department, University College Hospital (UCH), Ibadan, Nigeria, a total of 370 standard treatment plans in two alternative sets were generated with HDR basic 2.6 software for one hundred and eighty five cervical cancer patients. The initial 185 individual plans were created for clinical treatment using the tandem-ring dwell time ratio of 1 : 1. Modifying the initial applicator loading ratio, the second set of plans with related dose data were also obtained for study purposes only. Total reference air kerma (TRAK), total time index (TTI), ICRU volume, treatment time, point B dose, ICRU bladder dose, and rectal points dose were evaluated for both sets of plans. RESULTS: The means of all evaluated dose parameters decreased when the existing tandem-ring dwell time ratio (1 : 1) was modified to other dwell weightings (1 : 1 – 3 : 1). These reductions were 13.43% (ICRU volume), 9.83% (rectal dose), 6.68% (point B dose), 6.08% (treatment time), 5.90% (TRAK), 5.88% (TTI), and 1.08% (bladder dose). Correspondingly, coefficients of variation changed by –7.98%, –5.02%, –5.23%, –4.20%, –3.93%, 8.65%, and 3.96% from the existing pattern to the alternative one. CONCLUSION: Tandem-ring dwell time ratio has significant influence on dosimetric parameters. This study has indicated the need to modify the existing planning approach at UCH.
format Online
Article
Text
id pubmed-4444453
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Termedia Publishing House
record_format MEDLINE/PubMed
spelling pubmed-44444532015-06-01 Tandem-ring dwell time ratio in Nigeria: dose comparisons of two loading patterns in standard high-dose-rate brachytherapy planning for cervical cancer Ibhade, Obed Rachel Oyeyemi, Oyekunle Emmanuel Idayat, Akinlade Bidemi Atara I., Ntekim J Contemp Brachytherapy Original Paper PURPOSE: In high-dose-rate (HDR) brachytherapy (BT), the source dwell times and dwell positions are essential treatment planning parameters. An optimal choice of these factors is fundamental to obtain the desired target coverage with the lowest achievable dose to the organs at risk (OARs). This study evaluates relevant dose parameters in cervix brachytherapy in order to assess existing tandem-ring dwell time ratio used at the first HDR BT center in Nigeria, and compare it with an alternative source loading pattern. MATERIAL AND METHODS: At the Radiotherapy Department, University College Hospital (UCH), Ibadan, Nigeria, a total of 370 standard treatment plans in two alternative sets were generated with HDR basic 2.6 software for one hundred and eighty five cervical cancer patients. The initial 185 individual plans were created for clinical treatment using the tandem-ring dwell time ratio of 1 : 1. Modifying the initial applicator loading ratio, the second set of plans with related dose data were also obtained for study purposes only. Total reference air kerma (TRAK), total time index (TTI), ICRU volume, treatment time, point B dose, ICRU bladder dose, and rectal points dose were evaluated for both sets of plans. RESULTS: The means of all evaluated dose parameters decreased when the existing tandem-ring dwell time ratio (1 : 1) was modified to other dwell weightings (1 : 1 – 3 : 1). These reductions were 13.43% (ICRU volume), 9.83% (rectal dose), 6.68% (point B dose), 6.08% (treatment time), 5.90% (TRAK), 5.88% (TTI), and 1.08% (bladder dose). Correspondingly, coefficients of variation changed by –7.98%, –5.02%, –5.23%, –4.20%, –3.93%, 8.65%, and 3.96% from the existing pattern to the alternative one. CONCLUSION: Tandem-ring dwell time ratio has significant influence on dosimetric parameters. This study has indicated the need to modify the existing planning approach at UCH. Termedia Publishing House 2015-04-01 2015-04 /pmc/articles/PMC4444453/ /pubmed/26034498 http://dx.doi.org/10.5114/jcb.2015.50660 Text en Copyright © 2015 Termedia http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial 3.0 Unported License, permitting all non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Paper
Ibhade, Obed Rachel
Oyeyemi, Oyekunle Emmanuel
Idayat, Akinlade Bidemi
Atara I., Ntekim
Tandem-ring dwell time ratio in Nigeria: dose comparisons of two loading patterns in standard high-dose-rate brachytherapy planning for cervical cancer
title Tandem-ring dwell time ratio in Nigeria: dose comparisons of two loading patterns in standard high-dose-rate brachytherapy planning for cervical cancer
title_full Tandem-ring dwell time ratio in Nigeria: dose comparisons of two loading patterns in standard high-dose-rate brachytherapy planning for cervical cancer
title_fullStr Tandem-ring dwell time ratio in Nigeria: dose comparisons of two loading patterns in standard high-dose-rate brachytherapy planning for cervical cancer
title_full_unstemmed Tandem-ring dwell time ratio in Nigeria: dose comparisons of two loading patterns in standard high-dose-rate brachytherapy planning for cervical cancer
title_short Tandem-ring dwell time ratio in Nigeria: dose comparisons of two loading patterns in standard high-dose-rate brachytherapy planning for cervical cancer
title_sort tandem-ring dwell time ratio in nigeria: dose comparisons of two loading patterns in standard high-dose-rate brachytherapy planning for cervical cancer
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4444453/
https://www.ncbi.nlm.nih.gov/pubmed/26034498
http://dx.doi.org/10.5114/jcb.2015.50660
work_keys_str_mv AT ibhadeobedrachel tandemringdwelltimeratioinnigeriadosecomparisonsoftwoloadingpatternsinstandardhighdoseratebrachytherapyplanningforcervicalcancer
AT oyeyemioyekunleemmanuel tandemringdwelltimeratioinnigeriadosecomparisonsoftwoloadingpatternsinstandardhighdoseratebrachytherapyplanningforcervicalcancer
AT idayatakinladebidemi tandemringdwelltimeratioinnigeriadosecomparisonsoftwoloadingpatternsinstandardhighdoseratebrachytherapyplanningforcervicalcancer
AT ataraintekim tandemringdwelltimeratioinnigeriadosecomparisonsoftwoloadingpatternsinstandardhighdoseratebrachytherapyplanningforcervicalcancer