Comparison of cytologic accuracy of endobronchial ultrasound transbronchial needle aspiration using needle suction versus no suction
BACKGROUND AND OBJECTIVES: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a relatively new procedure initially used for lung cancer diagnosis, staging and re-staging and extended to benign diseases such as sarcoidosis and other mediastinal lesions. Previously, multip...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4445168/ https://www.ncbi.nlm.nih.gov/pubmed/26020045 http://dx.doi.org/10.4103/2303-9027.156737 |
_version_ | 1782373241616072704 |
---|---|
author | Harris, Kassem Maroun, Rabih Attwood, Kristopher Chalhoub, Michel |
author_facet | Harris, Kassem Maroun, Rabih Attwood, Kristopher Chalhoub, Michel |
author_sort | Harris, Kassem |
collection | PubMed |
description | BACKGROUND AND OBJECTIVES: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a relatively new procedure initially used for lung cancer diagnosis, staging and re-staging and extended to benign diseases such as sarcoidosis and other mediastinal lesions. Previously, multiple studies evaluated the use of needle biopsy with no aspiration that did not change the diagnostic accuracy compared with needle biopsy aspiration. MATERIALS AND METHODS: All adult subjects who were scheduled to undergo EBUS-TBNA to sample mediastinal lesions were eligible. We evaluated two methods of sampling mediastinal lesions. The first method was the application of negative pressure syringe for needle suction aspiration. The second was with no suction. For every patient and every biopsy site in the same patient, we had two samples using each method. RESULTS: Among the 26 participants, 24 patients had adequate tissue using both methods (92.3%, P = 1.00). Among the 24 patients with adequate tissue using both methods, 14 patients (58.3%) had benign pathology using both methods, whereas ten patients (41.7%) had malignant pathology using both methods (P = 1.00). Among the 32 sites that were sampled, 30 sites had adequate tissue using both methods (93.8%, P = 1.00). Among the thirty sites with adequate tissue using both methods, 17 (56.7%) had benign pathology using both methods; 12 (40.0%) had malignant pathology using both methods; and one site (3.3%) had malignant pathology using suction, but benign pathology using no suction (P = 1.00). CONCLUSION: In patients undergoing EBUS-TBNA to sample mediastinal lesions, the diagnostic yield with the application of suction to needle biopsy was not statistically significant compared to no suction. |
format | Online Article Text |
id | pubmed-4445168 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-44451682015-05-27 Comparison of cytologic accuracy of endobronchial ultrasound transbronchial needle aspiration using needle suction versus no suction Harris, Kassem Maroun, Rabih Attwood, Kristopher Chalhoub, Michel Endosc Ultrasound Original Article BACKGROUND AND OBJECTIVES: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a relatively new procedure initially used for lung cancer diagnosis, staging and re-staging and extended to benign diseases such as sarcoidosis and other mediastinal lesions. Previously, multiple studies evaluated the use of needle biopsy with no aspiration that did not change the diagnostic accuracy compared with needle biopsy aspiration. MATERIALS AND METHODS: All adult subjects who were scheduled to undergo EBUS-TBNA to sample mediastinal lesions were eligible. We evaluated two methods of sampling mediastinal lesions. The first method was the application of negative pressure syringe for needle suction aspiration. The second was with no suction. For every patient and every biopsy site in the same patient, we had two samples using each method. RESULTS: Among the 26 participants, 24 patients had adequate tissue using both methods (92.3%, P = 1.00). Among the 24 patients with adequate tissue using both methods, 14 patients (58.3%) had benign pathology using both methods, whereas ten patients (41.7%) had malignant pathology using both methods (P = 1.00). Among the 32 sites that were sampled, 30 sites had adequate tissue using both methods (93.8%, P = 1.00). Among the thirty sites with adequate tissue using both methods, 17 (56.7%) had benign pathology using both methods; 12 (40.0%) had malignant pathology using both methods; and one site (3.3%) had malignant pathology using suction, but benign pathology using no suction (P = 1.00). CONCLUSION: In patients undergoing EBUS-TBNA to sample mediastinal lesions, the diagnostic yield with the application of suction to needle biopsy was not statistically significant compared to no suction. Medknow Publications & Media Pvt Ltd 2015 /pmc/articles/PMC4445168/ /pubmed/26020045 http://dx.doi.org/10.4103/2303-9027.156737 Text en Copyright: © Endoscopic Ultrasound http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Harris, Kassem Maroun, Rabih Attwood, Kristopher Chalhoub, Michel Comparison of cytologic accuracy of endobronchial ultrasound transbronchial needle aspiration using needle suction versus no suction |
title | Comparison of cytologic accuracy of endobronchial ultrasound transbronchial needle aspiration using needle suction versus no suction |
title_full | Comparison of cytologic accuracy of endobronchial ultrasound transbronchial needle aspiration using needle suction versus no suction |
title_fullStr | Comparison of cytologic accuracy of endobronchial ultrasound transbronchial needle aspiration using needle suction versus no suction |
title_full_unstemmed | Comparison of cytologic accuracy of endobronchial ultrasound transbronchial needle aspiration using needle suction versus no suction |
title_short | Comparison of cytologic accuracy of endobronchial ultrasound transbronchial needle aspiration using needle suction versus no suction |
title_sort | comparison of cytologic accuracy of endobronchial ultrasound transbronchial needle aspiration using needle suction versus no suction |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4445168/ https://www.ncbi.nlm.nih.gov/pubmed/26020045 http://dx.doi.org/10.4103/2303-9027.156737 |
work_keys_str_mv | AT harriskassem comparisonofcytologicaccuracyofendobronchialultrasoundtransbronchialneedleaspirationusingneedlesuctionversusnosuction AT marounrabih comparisonofcytologicaccuracyofendobronchialultrasoundtransbronchialneedleaspirationusingneedlesuctionversusnosuction AT attwoodkristopher comparisonofcytologicaccuracyofendobronchialultrasoundtransbronchialneedleaspirationusingneedlesuctionversusnosuction AT chalhoubmichel comparisonofcytologicaccuracyofendobronchialultrasoundtransbronchialneedleaspirationusingneedlesuctionversusnosuction |