Cargando…

Comparison of cytologic accuracy of endobronchial ultrasound transbronchial needle aspiration using needle suction versus no suction

BACKGROUND AND OBJECTIVES: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a relatively new procedure initially used for lung cancer diagnosis, staging and re-staging and extended to benign diseases such as sarcoidosis and other mediastinal lesions. Previously, multip...

Descripción completa

Detalles Bibliográficos
Autores principales: Harris, Kassem, Maroun, Rabih, Attwood, Kristopher, Chalhoub, Michel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4445168/
https://www.ncbi.nlm.nih.gov/pubmed/26020045
http://dx.doi.org/10.4103/2303-9027.156737
_version_ 1782373241616072704
author Harris, Kassem
Maroun, Rabih
Attwood, Kristopher
Chalhoub, Michel
author_facet Harris, Kassem
Maroun, Rabih
Attwood, Kristopher
Chalhoub, Michel
author_sort Harris, Kassem
collection PubMed
description BACKGROUND AND OBJECTIVES: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a relatively new procedure initially used for lung cancer diagnosis, staging and re-staging and extended to benign diseases such as sarcoidosis and other mediastinal lesions. Previously, multiple studies evaluated the use of needle biopsy with no aspiration that did not change the diagnostic accuracy compared with needle biopsy aspiration. MATERIALS AND METHODS: All adult subjects who were scheduled to undergo EBUS-TBNA to sample mediastinal lesions were eligible. We evaluated two methods of sampling mediastinal lesions. The first method was the application of negative pressure syringe for needle suction aspiration. The second was with no suction. For every patient and every biopsy site in the same patient, we had two samples using each method. RESULTS: Among the 26 participants, 24 patients had adequate tissue using both methods (92.3%, P = 1.00). Among the 24 patients with adequate tissue using both methods, 14 patients (58.3%) had benign pathology using both methods, whereas ten patients (41.7%) had malignant pathology using both methods (P = 1.00). Among the 32 sites that were sampled, 30 sites had adequate tissue using both methods (93.8%, P = 1.00). Among the thirty sites with adequate tissue using both methods, 17 (56.7%) had benign pathology using both methods; 12 (40.0%) had malignant pathology using both methods; and one site (3.3%) had malignant pathology using suction, but benign pathology using no suction (P = 1.00). CONCLUSION: In patients undergoing EBUS-TBNA to sample mediastinal lesions, the diagnostic yield with the application of suction to needle biopsy was not statistically significant compared to no suction.
format Online
Article
Text
id pubmed-4445168
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-44451682015-05-27 Comparison of cytologic accuracy of endobronchial ultrasound transbronchial needle aspiration using needle suction versus no suction Harris, Kassem Maroun, Rabih Attwood, Kristopher Chalhoub, Michel Endosc Ultrasound Original Article BACKGROUND AND OBJECTIVES: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a relatively new procedure initially used for lung cancer diagnosis, staging and re-staging and extended to benign diseases such as sarcoidosis and other mediastinal lesions. Previously, multiple studies evaluated the use of needle biopsy with no aspiration that did not change the diagnostic accuracy compared with needle biopsy aspiration. MATERIALS AND METHODS: All adult subjects who were scheduled to undergo EBUS-TBNA to sample mediastinal lesions were eligible. We evaluated two methods of sampling mediastinal lesions. The first method was the application of negative pressure syringe for needle suction aspiration. The second was with no suction. For every patient and every biopsy site in the same patient, we had two samples using each method. RESULTS: Among the 26 participants, 24 patients had adequate tissue using both methods (92.3%, P = 1.00). Among the 24 patients with adequate tissue using both methods, 14 patients (58.3%) had benign pathology using both methods, whereas ten patients (41.7%) had malignant pathology using both methods (P = 1.00). Among the 32 sites that were sampled, 30 sites had adequate tissue using both methods (93.8%, P = 1.00). Among the thirty sites with adequate tissue using both methods, 17 (56.7%) had benign pathology using both methods; 12 (40.0%) had malignant pathology using both methods; and one site (3.3%) had malignant pathology using suction, but benign pathology using no suction (P = 1.00). CONCLUSION: In patients undergoing EBUS-TBNA to sample mediastinal lesions, the diagnostic yield with the application of suction to needle biopsy was not statistically significant compared to no suction. Medknow Publications & Media Pvt Ltd 2015 /pmc/articles/PMC4445168/ /pubmed/26020045 http://dx.doi.org/10.4103/2303-9027.156737 Text en Copyright: © Endoscopic Ultrasound http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Harris, Kassem
Maroun, Rabih
Attwood, Kristopher
Chalhoub, Michel
Comparison of cytologic accuracy of endobronchial ultrasound transbronchial needle aspiration using needle suction versus no suction
title Comparison of cytologic accuracy of endobronchial ultrasound transbronchial needle aspiration using needle suction versus no suction
title_full Comparison of cytologic accuracy of endobronchial ultrasound transbronchial needle aspiration using needle suction versus no suction
title_fullStr Comparison of cytologic accuracy of endobronchial ultrasound transbronchial needle aspiration using needle suction versus no suction
title_full_unstemmed Comparison of cytologic accuracy of endobronchial ultrasound transbronchial needle aspiration using needle suction versus no suction
title_short Comparison of cytologic accuracy of endobronchial ultrasound transbronchial needle aspiration using needle suction versus no suction
title_sort comparison of cytologic accuracy of endobronchial ultrasound transbronchial needle aspiration using needle suction versus no suction
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4445168/
https://www.ncbi.nlm.nih.gov/pubmed/26020045
http://dx.doi.org/10.4103/2303-9027.156737
work_keys_str_mv AT harriskassem comparisonofcytologicaccuracyofendobronchialultrasoundtransbronchialneedleaspirationusingneedlesuctionversusnosuction
AT marounrabih comparisonofcytologicaccuracyofendobronchialultrasoundtransbronchialneedleaspirationusingneedlesuctionversusnosuction
AT attwoodkristopher comparisonofcytologicaccuracyofendobronchialultrasoundtransbronchialneedleaspirationusingneedlesuctionversusnosuction
AT chalhoubmichel comparisonofcytologicaccuracyofendobronchialultrasoundtransbronchialneedleaspirationusingneedlesuctionversusnosuction