Cargando…

Quantitative Analysis of Torso FDG-PET Scans by Using Anatomical Standardization of Normal Cases from Thorough Physical Examinations

Understanding of standardized uptake value (SUV) of 2-deoxy-2-[18F]fluoro-d-glucose positron emission tomography (FDG-PET) depends on the background accumulations of glucose because the SUV often varies the status of patients. The purpose of this study was to develop a new method for quantitative an...

Descripción completa

Detalles Bibliográficos
Autores principales: Hara, Takeshi, Kobayashi, Tatsunori, Ito, Satoshi, Zhou, Xiangrong, Katafuchi, Tetsuro, Fujita, Hiroshi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4447288/
https://www.ncbi.nlm.nih.gov/pubmed/26020960
http://dx.doi.org/10.1371/journal.pone.0125713
_version_ 1782373571488645120
author Hara, Takeshi
Kobayashi, Tatsunori
Ito, Satoshi
Zhou, Xiangrong
Katafuchi, Tetsuro
Fujita, Hiroshi
author_facet Hara, Takeshi
Kobayashi, Tatsunori
Ito, Satoshi
Zhou, Xiangrong
Katafuchi, Tetsuro
Fujita, Hiroshi
author_sort Hara, Takeshi
collection PubMed
description Understanding of standardized uptake value (SUV) of 2-deoxy-2-[18F]fluoro-d-glucose positron emission tomography (FDG-PET) depends on the background accumulations of glucose because the SUV often varies the status of patients. The purpose of this study was to develop a new method for quantitative analysis of SUV of FDG-PET scan images. The method included an anatomical standardization and a statistical comparison with normal cases by using Z-score that are often used in SPM or 3D-SSP approach for brain function analysis. Our scheme consisted of two approaches, which included the construction of a normal model and the determination of the SUV scores as Z-score index for measuring the abnormality of an FDG-PET scan image. To construct the normal torso model, all of the normal images were registered into one shape, which indicated the normal range of SUV at all voxels. The image deformation process consisted of a whole body rigid registration of shoulder to bladder region and liver registration and a non-linear registration of body surface by using the thin-plate spline technique. In order to validate usefulness of our method, we segment suspicious regions on FDG-PET images manually, and obtained the Z-scores of the regions based on the corresponding voxels that stores the mean and the standard deviations from the normal model. We collected 243 (143 males and 100 females) normal cases to construct the normal model. We also extracted 432 abnormal spots from 63 abnormal cases (73 cancer lesions) to validate the Z-scores. The Z-scores of 417 out of 432 abnormal spots were higher than 2.0, which statistically indicated the severity of the spots. In conclusions, the Z-scores obtained by our computerized scheme with anatomical standardization of torso region would be useful for visualization and detection of subtle lesions on FDG-PET scan images even when the SUV may not clearly show an abnormality.
format Online
Article
Text
id pubmed-4447288
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-44472882015-06-09 Quantitative Analysis of Torso FDG-PET Scans by Using Anatomical Standardization of Normal Cases from Thorough Physical Examinations Hara, Takeshi Kobayashi, Tatsunori Ito, Satoshi Zhou, Xiangrong Katafuchi, Tetsuro Fujita, Hiroshi PLoS One Research Article Understanding of standardized uptake value (SUV) of 2-deoxy-2-[18F]fluoro-d-glucose positron emission tomography (FDG-PET) depends on the background accumulations of glucose because the SUV often varies the status of patients. The purpose of this study was to develop a new method for quantitative analysis of SUV of FDG-PET scan images. The method included an anatomical standardization and a statistical comparison with normal cases by using Z-score that are often used in SPM or 3D-SSP approach for brain function analysis. Our scheme consisted of two approaches, which included the construction of a normal model and the determination of the SUV scores as Z-score index for measuring the abnormality of an FDG-PET scan image. To construct the normal torso model, all of the normal images were registered into one shape, which indicated the normal range of SUV at all voxels. The image deformation process consisted of a whole body rigid registration of shoulder to bladder region and liver registration and a non-linear registration of body surface by using the thin-plate spline technique. In order to validate usefulness of our method, we segment suspicious regions on FDG-PET images manually, and obtained the Z-scores of the regions based on the corresponding voxels that stores the mean and the standard deviations from the normal model. We collected 243 (143 males and 100 females) normal cases to construct the normal model. We also extracted 432 abnormal spots from 63 abnormal cases (73 cancer lesions) to validate the Z-scores. The Z-scores of 417 out of 432 abnormal spots were higher than 2.0, which statistically indicated the severity of the spots. In conclusions, the Z-scores obtained by our computerized scheme with anatomical standardization of torso region would be useful for visualization and detection of subtle lesions on FDG-PET scan images even when the SUV may not clearly show an abnormality. Public Library of Science 2015-05-28 /pmc/articles/PMC4447288/ /pubmed/26020960 http://dx.doi.org/10.1371/journal.pone.0125713 Text en © 2015 Hara et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Hara, Takeshi
Kobayashi, Tatsunori
Ito, Satoshi
Zhou, Xiangrong
Katafuchi, Tetsuro
Fujita, Hiroshi
Quantitative Analysis of Torso FDG-PET Scans by Using Anatomical Standardization of Normal Cases from Thorough Physical Examinations
title Quantitative Analysis of Torso FDG-PET Scans by Using Anatomical Standardization of Normal Cases from Thorough Physical Examinations
title_full Quantitative Analysis of Torso FDG-PET Scans by Using Anatomical Standardization of Normal Cases from Thorough Physical Examinations
title_fullStr Quantitative Analysis of Torso FDG-PET Scans by Using Anatomical Standardization of Normal Cases from Thorough Physical Examinations
title_full_unstemmed Quantitative Analysis of Torso FDG-PET Scans by Using Anatomical Standardization of Normal Cases from Thorough Physical Examinations
title_short Quantitative Analysis of Torso FDG-PET Scans by Using Anatomical Standardization of Normal Cases from Thorough Physical Examinations
title_sort quantitative analysis of torso fdg-pet scans by using anatomical standardization of normal cases from thorough physical examinations
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4447288/
https://www.ncbi.nlm.nih.gov/pubmed/26020960
http://dx.doi.org/10.1371/journal.pone.0125713
work_keys_str_mv AT haratakeshi quantitativeanalysisoftorsofdgpetscansbyusinganatomicalstandardizationofnormalcasesfromthoroughphysicalexaminations
AT kobayashitatsunori quantitativeanalysisoftorsofdgpetscansbyusinganatomicalstandardizationofnormalcasesfromthoroughphysicalexaminations
AT itosatoshi quantitativeanalysisoftorsofdgpetscansbyusinganatomicalstandardizationofnormalcasesfromthoroughphysicalexaminations
AT zhouxiangrong quantitativeanalysisoftorsofdgpetscansbyusinganatomicalstandardizationofnormalcasesfromthoroughphysicalexaminations
AT katafuchitetsuro quantitativeanalysisoftorsofdgpetscansbyusinganatomicalstandardizationofnormalcasesfromthoroughphysicalexaminations
AT fujitahiroshi quantitativeanalysisoftorsofdgpetscansbyusinganatomicalstandardizationofnormalcasesfromthoroughphysicalexaminations