Cargando…

Musculoskeletal injuries in a resource-constrained environment: comparing diagnostic accuracy of on-the-spot ultrasonography and conventional radiography for bone fracture screening during the Paris–Dakar rally raid

BACKGROUND: Ultrasound (US) is a good first-line alternative for the diagnosis of bone fractures in adults as well as children. Our study shows that, compared to X-ray, in a resource-constrained environment, on-site US has a high sensitivity (98%) and specificity (96%) in the diagnosis of bone fract...

Descripción completa

Detalles Bibliográficos
Autores principales: Dallaudière, Benjamin, Larbi, Ahmed, Lefere, Mathieu, Perozziello, Anne, Hauger, Olivier, Pommerie, Florence, Fraboulet, Bénédicte, Jacob, Denis
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4447636/
https://www.ncbi.nlm.nih.gov/pubmed/26034643
http://dx.doi.org/10.1177/2058460115577566
_version_ 1782373611026251776
author Dallaudière, Benjamin
Larbi, Ahmed
Lefere, Mathieu
Perozziello, Anne
Hauger, Olivier
Pommerie, Florence
Fraboulet, Bénédicte
Jacob, Denis
author_facet Dallaudière, Benjamin
Larbi, Ahmed
Lefere, Mathieu
Perozziello, Anne
Hauger, Olivier
Pommerie, Florence
Fraboulet, Bénédicte
Jacob, Denis
author_sort Dallaudière, Benjamin
collection PubMed
description BACKGROUND: Ultrasound (US) is a good first-line alternative for the diagnosis of bone fractures in adults as well as children. Our study shows that, compared to X-ray, in a resource-constrained environment, on-site US has a high sensitivity (98%) and specificity (96%) in the diagnosis of bone fractures. PURPOSE: To compare the accuracy of on-the-spot US with conventional radiography in the screening for bone fractures during the Paris–Dakar rally raid. MATERIAL AND METHODS: Eighty-three patients (81 men, 2 women) with clinically suspected bone fractures were included in 2013 and 2014. They underwent X-ray and US on the spot, blindly interpreted by two musculoskeletal radiologists. Using X-ray as gold standard, we calculated sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for US, for each anatomic location. The accuracy of US and radiography were also assessed, as were the number of fragments and their degree of displacement (Student’s t-test). RESULTS: Compared with X-ray, sensitivity, specificity, PPV, and NPV of on-site US were, respectively, for the presence (or absence) of fractures: 98%, 98%, 100%, and 95%. The accuracy of US was 99%. Only one radial styloid process fracture was misdiagnosed with US. There was no significant difference between US and X-ray (P > 0.93) concerning the number of fragments and their degree of displacement. CONCLUSION: Bedside musculoskeletal ultrasound performed by trained musculoskeletal radiologists is a useful method in determining and assessing bone fractures in a resource constrained environment.
format Online
Article
Text
id pubmed-4447636
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-44476362015-06-01 Musculoskeletal injuries in a resource-constrained environment: comparing diagnostic accuracy of on-the-spot ultrasonography and conventional radiography for bone fracture screening during the Paris–Dakar rally raid Dallaudière, Benjamin Larbi, Ahmed Lefere, Mathieu Perozziello, Anne Hauger, Olivier Pommerie, Florence Fraboulet, Bénédicte Jacob, Denis Acta Radiol Open Original Article BACKGROUND: Ultrasound (US) is a good first-line alternative for the diagnosis of bone fractures in adults as well as children. Our study shows that, compared to X-ray, in a resource-constrained environment, on-site US has a high sensitivity (98%) and specificity (96%) in the diagnosis of bone fractures. PURPOSE: To compare the accuracy of on-the-spot US with conventional radiography in the screening for bone fractures during the Paris–Dakar rally raid. MATERIAL AND METHODS: Eighty-three patients (81 men, 2 women) with clinically suspected bone fractures were included in 2013 and 2014. They underwent X-ray and US on the spot, blindly interpreted by two musculoskeletal radiologists. Using X-ray as gold standard, we calculated sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for US, for each anatomic location. The accuracy of US and radiography were also assessed, as were the number of fragments and their degree of displacement (Student’s t-test). RESULTS: Compared with X-ray, sensitivity, specificity, PPV, and NPV of on-site US were, respectively, for the presence (or absence) of fractures: 98%, 98%, 100%, and 95%. The accuracy of US was 99%. Only one radial styloid process fracture was misdiagnosed with US. There was no significant difference between US and X-ray (P > 0.93) concerning the number of fragments and their degree of displacement. CONCLUSION: Bedside musculoskeletal ultrasound performed by trained musculoskeletal radiologists is a useful method in determining and assessing bone fractures in a resource constrained environment. SAGE Publications 2015-05-27 /pmc/articles/PMC4447636/ /pubmed/26034643 http://dx.doi.org/10.1177/2058460115577566 Text en © The Foundation Acta Radiologica 2015 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav http://creativecommons.org/licenses/by-nc/3.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 3.0 License (http://www.creativecommons.org/licenses/by-nc/3.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page(http://www.uk.sagepub.com/aboutus/openaccess.htm).
spellingShingle Original Article
Dallaudière, Benjamin
Larbi, Ahmed
Lefere, Mathieu
Perozziello, Anne
Hauger, Olivier
Pommerie, Florence
Fraboulet, Bénédicte
Jacob, Denis
Musculoskeletal injuries in a resource-constrained environment: comparing diagnostic accuracy of on-the-spot ultrasonography and conventional radiography for bone fracture screening during the Paris–Dakar rally raid
title Musculoskeletal injuries in a resource-constrained environment: comparing diagnostic accuracy of on-the-spot ultrasonography and conventional radiography for bone fracture screening during the Paris–Dakar rally raid
title_full Musculoskeletal injuries in a resource-constrained environment: comparing diagnostic accuracy of on-the-spot ultrasonography and conventional radiography for bone fracture screening during the Paris–Dakar rally raid
title_fullStr Musculoskeletal injuries in a resource-constrained environment: comparing diagnostic accuracy of on-the-spot ultrasonography and conventional radiography for bone fracture screening during the Paris–Dakar rally raid
title_full_unstemmed Musculoskeletal injuries in a resource-constrained environment: comparing diagnostic accuracy of on-the-spot ultrasonography and conventional radiography for bone fracture screening during the Paris–Dakar rally raid
title_short Musculoskeletal injuries in a resource-constrained environment: comparing diagnostic accuracy of on-the-spot ultrasonography and conventional radiography for bone fracture screening during the Paris–Dakar rally raid
title_sort musculoskeletal injuries in a resource-constrained environment: comparing diagnostic accuracy of on-the-spot ultrasonography and conventional radiography for bone fracture screening during the paris–dakar rally raid
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4447636/
https://www.ncbi.nlm.nih.gov/pubmed/26034643
http://dx.doi.org/10.1177/2058460115577566
work_keys_str_mv AT dallaudierebenjamin musculoskeletalinjuriesinaresourceconstrainedenvironmentcomparingdiagnosticaccuracyofonthespotultrasonographyandconventionalradiographyforbonefracturescreeningduringtheparisdakarrallyraid
AT larbiahmed musculoskeletalinjuriesinaresourceconstrainedenvironmentcomparingdiagnosticaccuracyofonthespotultrasonographyandconventionalradiographyforbonefracturescreeningduringtheparisdakarrallyraid
AT leferemathieu musculoskeletalinjuriesinaresourceconstrainedenvironmentcomparingdiagnosticaccuracyofonthespotultrasonographyandconventionalradiographyforbonefracturescreeningduringtheparisdakarrallyraid
AT perozzielloanne musculoskeletalinjuriesinaresourceconstrainedenvironmentcomparingdiagnosticaccuracyofonthespotultrasonographyandconventionalradiographyforbonefracturescreeningduringtheparisdakarrallyraid
AT haugerolivier musculoskeletalinjuriesinaresourceconstrainedenvironmentcomparingdiagnosticaccuracyofonthespotultrasonographyandconventionalradiographyforbonefracturescreeningduringtheparisdakarrallyraid
AT pommerieflorence musculoskeletalinjuriesinaresourceconstrainedenvironmentcomparingdiagnosticaccuracyofonthespotultrasonographyandconventionalradiographyforbonefracturescreeningduringtheparisdakarrallyraid
AT frabouletbenedicte musculoskeletalinjuriesinaresourceconstrainedenvironmentcomparingdiagnosticaccuracyofonthespotultrasonographyandconventionalradiographyforbonefracturescreeningduringtheparisdakarrallyraid
AT jacobdenis musculoskeletalinjuriesinaresourceconstrainedenvironmentcomparingdiagnosticaccuracyofonthespotultrasonographyandconventionalradiographyforbonefracturescreeningduringtheparisdakarrallyraid