Detection of Nitro-Based and Peroxide-Based Explosives by Fast Polarity-Switchable Ion Mobility Spectrometer with Ion Focusing in Vicinity of Faraday Detector

Ion mobility spectrometer (IMS) has been widely deployed for on-site detection of explosives. The common nitro-based explosives are usually detected by negative IMS while the emerging peroxide-based explosives are better detected by positive IMS. In this study, a fast polarity-switchable IMS was con...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhou, Qinghua, Peng, Liying, Jiang, Dandan, Wang, Xin, Wang, Haiyan, Li, Haiyang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4448110/
https://www.ncbi.nlm.nih.gov/pubmed/26021282
http://dx.doi.org/10.1038/srep10659
_version_ 1782373656109776896
author Zhou, Qinghua
Peng, Liying
Jiang, Dandan
Wang, Xin
Wang, Haiyan
Li, Haiyang
author_facet Zhou, Qinghua
Peng, Liying
Jiang, Dandan
Wang, Xin
Wang, Haiyan
Li, Haiyang
author_sort Zhou, Qinghua
collection PubMed
description Ion mobility spectrometer (IMS) has been widely deployed for on-site detection of explosives. The common nitro-based explosives are usually detected by negative IMS while the emerging peroxide-based explosives are better detected by positive IMS. In this study, a fast polarity-switchable IMS was constructed to detect these two explosive species in a single measurement. As the large traditional Faraday detector would cause a trailing reactant ion peak (RIP), a Faraday detector with ion focusing in vicinity was developed by reducing the detector radius to 3.3 mm and increasing the voltage difference between aperture grid and its front guard ring to 591 V, which could remove trailing peaks from RIP without loss of signal intensity. This fast polarity-switchable IMS with ion focusing in vicinity of Faraday detector was employed to detect a mixture of 10 ng 2,4,6-trinitrotoluene (TNT) and 50 ng hexamethylene triperoxide diamine (HMTD) by polarity-switching, and the result suggested that [TNT-H](−) and [HMTD+H](+) could be detected in a single measurement. Furthermore, the removal of trailing peaks from RIP by the Faraday detector with ion focusing in vicinity also promised the accurate identification of KClO(4), KNO(3) and S in common inorganic explosives, whose product ion peaks were fairly adjacent to RIP.
format Online
Article
Text
id pubmed-4448110
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Nature Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-44481102015-06-10 Detection of Nitro-Based and Peroxide-Based Explosives by Fast Polarity-Switchable Ion Mobility Spectrometer with Ion Focusing in Vicinity of Faraday Detector Zhou, Qinghua Peng, Liying Jiang, Dandan Wang, Xin Wang, Haiyan Li, Haiyang Sci Rep Article Ion mobility spectrometer (IMS) has been widely deployed for on-site detection of explosives. The common nitro-based explosives are usually detected by negative IMS while the emerging peroxide-based explosives are better detected by positive IMS. In this study, a fast polarity-switchable IMS was constructed to detect these two explosive species in a single measurement. As the large traditional Faraday detector would cause a trailing reactant ion peak (RIP), a Faraday detector with ion focusing in vicinity was developed by reducing the detector radius to 3.3 mm and increasing the voltage difference between aperture grid and its front guard ring to 591 V, which could remove trailing peaks from RIP without loss of signal intensity. This fast polarity-switchable IMS with ion focusing in vicinity of Faraday detector was employed to detect a mixture of 10 ng 2,4,6-trinitrotoluene (TNT) and 50 ng hexamethylene triperoxide diamine (HMTD) by polarity-switching, and the result suggested that [TNT-H](−) and [HMTD+H](+) could be detected in a single measurement. Furthermore, the removal of trailing peaks from RIP by the Faraday detector with ion focusing in vicinity also promised the accurate identification of KClO(4), KNO(3) and S in common inorganic explosives, whose product ion peaks were fairly adjacent to RIP. Nature Publishing Group 2015-05-29 /pmc/articles/PMC4448110/ /pubmed/26021282 http://dx.doi.org/10.1038/srep10659 Text en Copyright © 2015, Macmillan Publishers Limited http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/
spellingShingle Article
Zhou, Qinghua
Peng, Liying
Jiang, Dandan
Wang, Xin
Wang, Haiyan
Li, Haiyang
Detection of Nitro-Based and Peroxide-Based Explosives by Fast Polarity-Switchable Ion Mobility Spectrometer with Ion Focusing in Vicinity of Faraday Detector
title Detection of Nitro-Based and Peroxide-Based Explosives by Fast Polarity-Switchable Ion Mobility Spectrometer with Ion Focusing in Vicinity of Faraday Detector
title_full Detection of Nitro-Based and Peroxide-Based Explosives by Fast Polarity-Switchable Ion Mobility Spectrometer with Ion Focusing in Vicinity of Faraday Detector
title_fullStr Detection of Nitro-Based and Peroxide-Based Explosives by Fast Polarity-Switchable Ion Mobility Spectrometer with Ion Focusing in Vicinity of Faraday Detector
title_full_unstemmed Detection of Nitro-Based and Peroxide-Based Explosives by Fast Polarity-Switchable Ion Mobility Spectrometer with Ion Focusing in Vicinity of Faraday Detector
title_short Detection of Nitro-Based and Peroxide-Based Explosives by Fast Polarity-Switchable Ion Mobility Spectrometer with Ion Focusing in Vicinity of Faraday Detector
title_sort detection of nitro-based and peroxide-based explosives by fast polarity-switchable ion mobility spectrometer with ion focusing in vicinity of faraday detector
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4448110/
https://www.ncbi.nlm.nih.gov/pubmed/26021282
http://dx.doi.org/10.1038/srep10659
work_keys_str_mv AT zhouqinghua detectionofnitrobasedandperoxidebasedexplosivesbyfastpolarityswitchableionmobilityspectrometerwithionfocusinginvicinityoffaradaydetector
AT pengliying detectionofnitrobasedandperoxidebasedexplosivesbyfastpolarityswitchableionmobilityspectrometerwithionfocusinginvicinityoffaradaydetector
AT jiangdandan detectionofnitrobasedandperoxidebasedexplosivesbyfastpolarityswitchableionmobilityspectrometerwithionfocusinginvicinityoffaradaydetector
AT wangxin detectionofnitrobasedandperoxidebasedexplosivesbyfastpolarityswitchableionmobilityspectrometerwithionfocusinginvicinityoffaradaydetector
AT wanghaiyan detectionofnitrobasedandperoxidebasedexplosivesbyfastpolarityswitchableionmobilityspectrometerwithionfocusinginvicinityoffaradaydetector
AT lihaiyang detectionofnitrobasedandperoxidebasedexplosivesbyfastpolarityswitchableionmobilityspectrometerwithionfocusinginvicinityoffaradaydetector