Optical coherence tomography to evaluate the interaction of different edge designs of four different silicone hydrogel lenses with the ocular surface
PURPOSE: To evaluate the lens edge interaction with the ocular surface with different edge designs using optical coherence tomography and to examine the effect of lens power on the lens edge interactions. METHODS: Four types of silicone hydrogel lenses with different edge designs (round-, semi-round...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4448929/ https://www.ncbi.nlm.nih.gov/pubmed/26045658 http://dx.doi.org/10.2147/OPTH.S83798 |
_version_ | 1782373791252348928 |
---|---|
author | Turhan, Semra Akkaya Toker, Ebru |
author_facet | Turhan, Semra Akkaya Toker, Ebru |
author_sort | Turhan, Semra Akkaya |
collection | PubMed |
description | PURPOSE: To evaluate the lens edge interaction with the ocular surface with different edge designs using optical coherence tomography and to examine the effect of lens power on the lens edge interactions. METHODS: Four types of silicone hydrogel lenses with different edge designs (round-, semi-round-, chisel-, and knife-edged) at six different powers (+5.0, +3.0, +1.0, −1.0, −3.0, and −5.0 diopters) were fitted to both eyes of 20 healthy volunteers. Optical coherence tomography images were taken at the corneal center and at the limbus within 15–30 minutes after insertion. The images were evaluated with respect to two parameters: conjunctival indentation exerted by the lens edge; and the tear film gaps between the posterior surface of the lens and the ocular surface. The amount of conjunctival indentation was measured with the distortion angle of the conjunctiva at the lens edge. RESULTS: The degree of conjunctival indentation was highest with the chisel-edged design followed by the semi-round design (P<0.0001). Knife- and round-edged lenses exerted similar levels of conjunctival indentation that was significantly lower compared to chisel-edged lens (P<0.001). For each one of the tested lens edge designs, no significant difference was observed in the conjunctival indentation with respect to lens power. The chisel-edged lens produced the highest amount of conjunctival indentation for each one of the six lens powers (P<0.0001). Post-lens tear film gaps at the limbus were observed at most in the round-edge design (P=0.001). CONCLUSION: The fitting properties of contact lenses may be influenced by their edge design but not by their lens power. |
format | Online Article Text |
id | pubmed-4448929 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-44489292015-06-04 Optical coherence tomography to evaluate the interaction of different edge designs of four different silicone hydrogel lenses with the ocular surface Turhan, Semra Akkaya Toker, Ebru Clin Ophthalmol Original Research PURPOSE: To evaluate the lens edge interaction with the ocular surface with different edge designs using optical coherence tomography and to examine the effect of lens power on the lens edge interactions. METHODS: Four types of silicone hydrogel lenses with different edge designs (round-, semi-round-, chisel-, and knife-edged) at six different powers (+5.0, +3.0, +1.0, −1.0, −3.0, and −5.0 diopters) were fitted to both eyes of 20 healthy volunteers. Optical coherence tomography images were taken at the corneal center and at the limbus within 15–30 minutes after insertion. The images were evaluated with respect to two parameters: conjunctival indentation exerted by the lens edge; and the tear film gaps between the posterior surface of the lens and the ocular surface. The amount of conjunctival indentation was measured with the distortion angle of the conjunctiva at the lens edge. RESULTS: The degree of conjunctival indentation was highest with the chisel-edged design followed by the semi-round design (P<0.0001). Knife- and round-edged lenses exerted similar levels of conjunctival indentation that was significantly lower compared to chisel-edged lens (P<0.001). For each one of the tested lens edge designs, no significant difference was observed in the conjunctival indentation with respect to lens power. The chisel-edged lens produced the highest amount of conjunctival indentation for each one of the six lens powers (P<0.0001). Post-lens tear film gaps at the limbus were observed at most in the round-edge design (P=0.001). CONCLUSION: The fitting properties of contact lenses may be influenced by their edge design but not by their lens power. Dove Medical Press 2015-05-25 /pmc/articles/PMC4448929/ /pubmed/26045658 http://dx.doi.org/10.2147/OPTH.S83798 Text en © 2015 Turhan and Toker. This work is published by Dove Medical Press Limited, and licensed under Creative Commons Attribution – Non Commercial (unported, v3.0) License The full terms of the License are available at http://creativecommons.org/licenses/by-nc/3.0/. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. |
spellingShingle | Original Research Turhan, Semra Akkaya Toker, Ebru Optical coherence tomography to evaluate the interaction of different edge designs of four different silicone hydrogel lenses with the ocular surface |
title | Optical coherence tomography to evaluate the interaction of different edge designs of four different silicone hydrogel lenses with the ocular surface |
title_full | Optical coherence tomography to evaluate the interaction of different edge designs of four different silicone hydrogel lenses with the ocular surface |
title_fullStr | Optical coherence tomography to evaluate the interaction of different edge designs of four different silicone hydrogel lenses with the ocular surface |
title_full_unstemmed | Optical coherence tomography to evaluate the interaction of different edge designs of four different silicone hydrogel lenses with the ocular surface |
title_short | Optical coherence tomography to evaluate the interaction of different edge designs of four different silicone hydrogel lenses with the ocular surface |
title_sort | optical coherence tomography to evaluate the interaction of different edge designs of four different silicone hydrogel lenses with the ocular surface |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4448929/ https://www.ncbi.nlm.nih.gov/pubmed/26045658 http://dx.doi.org/10.2147/OPTH.S83798 |
work_keys_str_mv | AT turhansemraakkaya opticalcoherencetomographytoevaluatetheinteractionofdifferentedgedesignsoffourdifferentsiliconehydrogellenseswiththeocularsurface AT tokerebru opticalcoherencetomographytoevaluatetheinteractionofdifferentedgedesignsoffourdifferentsiliconehydrogellenseswiththeocularsurface |