Cargando…

A Quantitative and Standardized Method for the Evaluation of Choroidal Neovascularization Using MICRON III Fluorescein Angiograms in Rats

INTRODUCTION: In-vivo imaging of choroidal neovascularization (CNV) has been increasingly recognized as a valuable tool in the investigation of age-related macular degeneration (AMD) in both clinical and basic research applications. Arguably the most widely utilised model replicating AMD is laser ge...

Descripción completa

Detalles Bibliográficos
Autores principales: Wigg, Jonathan P., Zhang, Hong, Yang, Dong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4449229/
https://www.ncbi.nlm.nih.gov/pubmed/26024231
http://dx.doi.org/10.1371/journal.pone.0128418
_version_ 1782373833725968384
author Wigg, Jonathan P.
Zhang, Hong
Yang, Dong
author_facet Wigg, Jonathan P.
Zhang, Hong
Yang, Dong
author_sort Wigg, Jonathan P.
collection PubMed
description INTRODUCTION: In-vivo imaging of choroidal neovascularization (CNV) has been increasingly recognized as a valuable tool in the investigation of age-related macular degeneration (AMD) in both clinical and basic research applications. Arguably the most widely utilised model replicating AMD is laser generated CNV by rupture of Bruch’s membrane in rodents. Heretofore CNV evaluation via in-vivo imaging techniques has been hamstrung by a lack of appropriate rodent fundus camera and a non-standardised analysis method. The aim of this study was to establish a simple, quantifiable method of fluorescein fundus angiogram (FFA) image analysis for CNV lesions. METHODS: Laser was applied to 32 Brown Norway Rats; FFA images were taken using a rodent specific fundus camera (Micron III, Phoenix Laboratories) over 3 weeks and compared to conventional ex-vivo CNV assessment. FFA images acquired with fluorescein administered by intraperitoneal injection and intravenous injection were compared and shown to greatly influence lesion properties. Utilising commonly used software packages, FFA images were assessed for CNV and chorioretinal burns lesion area by manually outlining the maximum border of each lesion and normalising against the optic nerve head. Net fluorescence above background and derived value of area corrected lesion intensity were calculated. RESULTS: CNV lesions of rats treated with anti-VEGF antibody were significantly smaller in normalised lesion area (p<0.001) and fluorescent intensity (p<0.001) than the PBS treated control two weeks post laser. The calculated area corrected lesion intensity was significantly smaller (p<0.001) in anti-VEGF treated animals at 2 and 3 weeks post laser. The results obtained using FFA correlated with, and were confirmed by conventional lesion area measurements from isolectin stained choroidal flatmounts, where lesions of anti-VEGF treated rats were significantly smaller at 2 weeks (p = 0.049) and 3 weeks (p<0.001) post laser. CONCLUSION: The presented method of in-vivo FFA quantification of CNV, including acquisition variable corrections, using the Micron III system and common use software establishes a reliable method for detecting and quantifying CNV enabling longitudinal studies and represents an important alternative to conventional CNV quantification methods.
format Online
Article
Text
id pubmed-4449229
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-44492292015-06-09 A Quantitative and Standardized Method for the Evaluation of Choroidal Neovascularization Using MICRON III Fluorescein Angiograms in Rats Wigg, Jonathan P. Zhang, Hong Yang, Dong PLoS One Research Article INTRODUCTION: In-vivo imaging of choroidal neovascularization (CNV) has been increasingly recognized as a valuable tool in the investigation of age-related macular degeneration (AMD) in both clinical and basic research applications. Arguably the most widely utilised model replicating AMD is laser generated CNV by rupture of Bruch’s membrane in rodents. Heretofore CNV evaluation via in-vivo imaging techniques has been hamstrung by a lack of appropriate rodent fundus camera and a non-standardised analysis method. The aim of this study was to establish a simple, quantifiable method of fluorescein fundus angiogram (FFA) image analysis for CNV lesions. METHODS: Laser was applied to 32 Brown Norway Rats; FFA images were taken using a rodent specific fundus camera (Micron III, Phoenix Laboratories) over 3 weeks and compared to conventional ex-vivo CNV assessment. FFA images acquired with fluorescein administered by intraperitoneal injection and intravenous injection were compared and shown to greatly influence lesion properties. Utilising commonly used software packages, FFA images were assessed for CNV and chorioretinal burns lesion area by manually outlining the maximum border of each lesion and normalising against the optic nerve head. Net fluorescence above background and derived value of area corrected lesion intensity were calculated. RESULTS: CNV lesions of rats treated with anti-VEGF antibody were significantly smaller in normalised lesion area (p<0.001) and fluorescent intensity (p<0.001) than the PBS treated control two weeks post laser. The calculated area corrected lesion intensity was significantly smaller (p<0.001) in anti-VEGF treated animals at 2 and 3 weeks post laser. The results obtained using FFA correlated with, and were confirmed by conventional lesion area measurements from isolectin stained choroidal flatmounts, where lesions of anti-VEGF treated rats were significantly smaller at 2 weeks (p = 0.049) and 3 weeks (p<0.001) post laser. CONCLUSION: The presented method of in-vivo FFA quantification of CNV, including acquisition variable corrections, using the Micron III system and common use software establishes a reliable method for detecting and quantifying CNV enabling longitudinal studies and represents an important alternative to conventional CNV quantification methods. Public Library of Science 2015-05-29 /pmc/articles/PMC4449229/ /pubmed/26024231 http://dx.doi.org/10.1371/journal.pone.0128418 Text en © 2015 Wigg et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Wigg, Jonathan P.
Zhang, Hong
Yang, Dong
A Quantitative and Standardized Method for the Evaluation of Choroidal Neovascularization Using MICRON III Fluorescein Angiograms in Rats
title A Quantitative and Standardized Method for the Evaluation of Choroidal Neovascularization Using MICRON III Fluorescein Angiograms in Rats
title_full A Quantitative and Standardized Method for the Evaluation of Choroidal Neovascularization Using MICRON III Fluorescein Angiograms in Rats
title_fullStr A Quantitative and Standardized Method for the Evaluation of Choroidal Neovascularization Using MICRON III Fluorescein Angiograms in Rats
title_full_unstemmed A Quantitative and Standardized Method for the Evaluation of Choroidal Neovascularization Using MICRON III Fluorescein Angiograms in Rats
title_short A Quantitative and Standardized Method for the Evaluation of Choroidal Neovascularization Using MICRON III Fluorescein Angiograms in Rats
title_sort quantitative and standardized method for the evaluation of choroidal neovascularization using micron iii fluorescein angiograms in rats
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4449229/
https://www.ncbi.nlm.nih.gov/pubmed/26024231
http://dx.doi.org/10.1371/journal.pone.0128418
work_keys_str_mv AT wiggjonathanp aquantitativeandstandardizedmethodfortheevaluationofchoroidalneovascularizationusingmicroniiifluoresceinangiogramsinrats
AT zhanghong aquantitativeandstandardizedmethodfortheevaluationofchoroidalneovascularizationusingmicroniiifluoresceinangiogramsinrats
AT yangdong aquantitativeandstandardizedmethodfortheevaluationofchoroidalneovascularizationusingmicroniiifluoresceinangiogramsinrats
AT wiggjonathanp quantitativeandstandardizedmethodfortheevaluationofchoroidalneovascularizationusingmicroniiifluoresceinangiogramsinrats
AT zhanghong quantitativeandstandardizedmethodfortheevaluationofchoroidalneovascularizationusingmicroniiifluoresceinangiogramsinrats
AT yangdong quantitativeandstandardizedmethodfortheevaluationofchoroidalneovascularizationusingmicroniiifluoresceinangiogramsinrats