Cargando…

Inhalation characteristics of asthma patients, COPD patients and healthy volunteers with the Spiromax® and Turbuhaler® devices: a randomised, cross-over study

BACKGROUND: Spiromax® is a novel dry-powder inhaler containing formulations of budesonide plus formoterol (BF). The device is intended to provide dose equivalence with enhanced user-friendliness compared to BF Turbuhaler® in asthma and chronic obstructive pulmonary disease (COPD). The present study...

Descripción completa

Detalles Bibliográficos
Autores principales: Azouz, Wahida, Chetcuti, Philip, Hosker, Harold, Saralaya, Dinesh, Chrystyn, Henry
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4450517/
https://www.ncbi.nlm.nih.gov/pubmed/25927483
http://dx.doi.org/10.1186/s12890-015-0043-x
_version_ 1782374014180655104
author Azouz, Wahida
Chetcuti, Philip
Hosker, Harold
Saralaya, Dinesh
Chrystyn, Henry
author_facet Azouz, Wahida
Chetcuti, Philip
Hosker, Harold
Saralaya, Dinesh
Chrystyn, Henry
author_sort Azouz, Wahida
collection PubMed
description BACKGROUND: Spiromax® is a novel dry-powder inhaler containing formulations of budesonide plus formoterol (BF). The device is intended to provide dose equivalence with enhanced user-friendliness compared to BF Turbuhaler® in asthma and chronic obstructive pulmonary disease (COPD). The present study was performed to compare inhalation parameters with empty versions of the two devices, and to investigate the effects of enhanced training designed to encourage faster inhalation. METHODS: This randomised, open-label, cross-over study included children with asthma (n = 23), adolescents with asthma (n = 27), adults with asthma (n = 50), adults with COPD (n = 50) and healthy adult volunteers (n = 50). Inhalation manoeuvres were recorded with each device after training with the patient information leaflet (PIL) and after enhanced training using an In-Check Dial device. RESULTS: After PIL training, peak inspiratory flow (PIF), maximum change in pressure (∆P) and the inhalation volume (IV) were significantly higher with Spiromax than with the Turbuhaler device (p values were at least <0.05 in all patient groups). After enhanced training, numerically or significantly higher values for PIF, ∆P, IV and acceleration remained with Spiromax versus Turbuhaler, except for ∆P in COPD patients. After PIL training, one adult asthma patient and one COPD patient inhaled <30 L/min through the Spiromax compared to one adult asthma patient and five COPD patients with the Turbuhaler. All patients achieved PIF values of at least 30 L/min after enhanced training. CONCLUSIONS: The two inhalers have similar resistance so inhalation flows and pressure changes would be expected to be similar. The higher flow-related values noted for Spiromax versus Turbuhaler after PIL training suggest that Spiromax might have human factor advantages in real-world use. After enhanced training, the flow-related differences between devices persisted; increased flow rates were achieved with both devices, and all patients achieved the minimal flow required for adequate drug delivery. Enhanced training could be useful, especially in COPD patients.
format Online
Article
Text
id pubmed-4450517
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-44505172015-06-02 Inhalation characteristics of asthma patients, COPD patients and healthy volunteers with the Spiromax® and Turbuhaler® devices: a randomised, cross-over study Azouz, Wahida Chetcuti, Philip Hosker, Harold Saralaya, Dinesh Chrystyn, Henry BMC Pulm Med Research Article BACKGROUND: Spiromax® is a novel dry-powder inhaler containing formulations of budesonide plus formoterol (BF). The device is intended to provide dose equivalence with enhanced user-friendliness compared to BF Turbuhaler® in asthma and chronic obstructive pulmonary disease (COPD). The present study was performed to compare inhalation parameters with empty versions of the two devices, and to investigate the effects of enhanced training designed to encourage faster inhalation. METHODS: This randomised, open-label, cross-over study included children with asthma (n = 23), adolescents with asthma (n = 27), adults with asthma (n = 50), adults with COPD (n = 50) and healthy adult volunteers (n = 50). Inhalation manoeuvres were recorded with each device after training with the patient information leaflet (PIL) and after enhanced training using an In-Check Dial device. RESULTS: After PIL training, peak inspiratory flow (PIF), maximum change in pressure (∆P) and the inhalation volume (IV) were significantly higher with Spiromax than with the Turbuhaler device (p values were at least <0.05 in all patient groups). After enhanced training, numerically or significantly higher values for PIF, ∆P, IV and acceleration remained with Spiromax versus Turbuhaler, except for ∆P in COPD patients. After PIL training, one adult asthma patient and one COPD patient inhaled <30 L/min through the Spiromax compared to one adult asthma patient and five COPD patients with the Turbuhaler. All patients achieved PIF values of at least 30 L/min after enhanced training. CONCLUSIONS: The two inhalers have similar resistance so inhalation flows and pressure changes would be expected to be similar. The higher flow-related values noted for Spiromax versus Turbuhaler after PIL training suggest that Spiromax might have human factor advantages in real-world use. After enhanced training, the flow-related differences between devices persisted; increased flow rates were achieved with both devices, and all patients achieved the minimal flow required for adequate drug delivery. Enhanced training could be useful, especially in COPD patients. BioMed Central 2015-05-01 /pmc/articles/PMC4450517/ /pubmed/25927483 http://dx.doi.org/10.1186/s12890-015-0043-x Text en © Azouz et al.; licensee BioMed Central. 2015 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Azouz, Wahida
Chetcuti, Philip
Hosker, Harold
Saralaya, Dinesh
Chrystyn, Henry
Inhalation characteristics of asthma patients, COPD patients and healthy volunteers with the Spiromax® and Turbuhaler® devices: a randomised, cross-over study
title Inhalation characteristics of asthma patients, COPD patients and healthy volunteers with the Spiromax® and Turbuhaler® devices: a randomised, cross-over study
title_full Inhalation characteristics of asthma patients, COPD patients and healthy volunteers with the Spiromax® and Turbuhaler® devices: a randomised, cross-over study
title_fullStr Inhalation characteristics of asthma patients, COPD patients and healthy volunteers with the Spiromax® and Turbuhaler® devices: a randomised, cross-over study
title_full_unstemmed Inhalation characteristics of asthma patients, COPD patients and healthy volunteers with the Spiromax® and Turbuhaler® devices: a randomised, cross-over study
title_short Inhalation characteristics of asthma patients, COPD patients and healthy volunteers with the Spiromax® and Turbuhaler® devices: a randomised, cross-over study
title_sort inhalation characteristics of asthma patients, copd patients and healthy volunteers with the spiromax® and turbuhaler® devices: a randomised, cross-over study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4450517/
https://www.ncbi.nlm.nih.gov/pubmed/25927483
http://dx.doi.org/10.1186/s12890-015-0043-x
work_keys_str_mv AT azouzwahida inhalationcharacteristicsofasthmapatientscopdpatientsandhealthyvolunteerswiththespiromaxandturbuhalerdevicesarandomisedcrossoverstudy
AT chetcutiphilip inhalationcharacteristicsofasthmapatientscopdpatientsandhealthyvolunteerswiththespiromaxandturbuhalerdevicesarandomisedcrossoverstudy
AT hoskerharold inhalationcharacteristicsofasthmapatientscopdpatientsandhealthyvolunteerswiththespiromaxandturbuhalerdevicesarandomisedcrossoverstudy
AT saralayadinesh inhalationcharacteristicsofasthmapatientscopdpatientsandhealthyvolunteerswiththespiromaxandturbuhalerdevicesarandomisedcrossoverstudy
AT chrystynhenry inhalationcharacteristicsofasthmapatientscopdpatientsandhealthyvolunteerswiththespiromaxandturbuhalerdevicesarandomisedcrossoverstudy