Primary Rotational Stability of Various Megaprostheses in a Biomechanical Sawbone Model with Proximal Femoral Defects Extending to the Isthmus

PURPOSE: Fixation of proximal femoral megaprostheses is achieved in the diaphyseal isthmus. We hypothesized that after extended bone resection including the proximal part of the isthmus a reduced length of fixation will affect the stability and fixation characteristics of these megaprostheses. The a...

Descripción completa

Detalles Bibliográficos
Autores principales: Kinkel, Stefan, Nadorf, Jan, Graage, Jan Dennis, Jakubowitz, Eike, Kretzer, Jan Philippe
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4451245/
https://www.ncbi.nlm.nih.gov/pubmed/26030460
http://dx.doi.org/10.1371/journal.pone.0129149
_version_ 1782374112205733888
author Kinkel, Stefan
Nadorf, Jan
Graage, Jan Dennis
Jakubowitz, Eike
Kretzer, Jan Philippe
author_facet Kinkel, Stefan
Nadorf, Jan
Graage, Jan Dennis
Jakubowitz, Eike
Kretzer, Jan Philippe
author_sort Kinkel, Stefan
collection PubMed
description PURPOSE: Fixation of proximal femoral megaprostheses is achieved in the diaphyseal isthmus. We hypothesized that after extended bone resection including the proximal part of the isthmus a reduced length of fixation will affect the stability and fixation characteristics of these megaprostheses. The aim of this study was to analyze in a validated sawbone model with extended proximal femoral defects which types of implants have sufficient primary stability to allow osteointegration and to describe their fixation characteristics. METHODS: Four different cementless megaprostheses were implanted into 16 Sawbones with an AAOS type III defect after resection 11cm below the lesser trochanter involving the proximal isthmus. To determine the primary implant stability relative micromotions between bone and implant were measured in relation to a cyclic torque of 7Nm applied on the longitudinal axis of the implant. We determined the fixation characteristics of the different implant designs by comparing these relative micromotions along the longitudinal stem axis. RESULTS: In the tested sawbones all studied implants showed sufficient primary stability to admit bone integration with relative micromotions below 150µm after adapting our results to physiologic hip joint loadings. Different fixation characteristics of the megaprostheses were determined, which could be explained by their differing design and fixation concepts. CONCLUSIONS: Cementless megaprostheses of different designs seem to provide sufficient primary stability to bridge proximal femoral defects if the diaphyseal isthmus is partially preserved. In our sawbone model the different implant fixation patterns can be related to their stem designs. No evidence can be provided to favor one of the studied implants in this setting. However, femoral morphology is variable and in different isthmus configurations specific implant designs might be appropriate to achieve the most favorable primary stability, which enables bone integration and consequently long term implant stability.
format Online
Article
Text
id pubmed-4451245
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-44512452015-06-09 Primary Rotational Stability of Various Megaprostheses in a Biomechanical Sawbone Model with Proximal Femoral Defects Extending to the Isthmus Kinkel, Stefan Nadorf, Jan Graage, Jan Dennis Jakubowitz, Eike Kretzer, Jan Philippe PLoS One Research Article PURPOSE: Fixation of proximal femoral megaprostheses is achieved in the diaphyseal isthmus. We hypothesized that after extended bone resection including the proximal part of the isthmus a reduced length of fixation will affect the stability and fixation characteristics of these megaprostheses. The aim of this study was to analyze in a validated sawbone model with extended proximal femoral defects which types of implants have sufficient primary stability to allow osteointegration and to describe their fixation characteristics. METHODS: Four different cementless megaprostheses were implanted into 16 Sawbones with an AAOS type III defect after resection 11cm below the lesser trochanter involving the proximal isthmus. To determine the primary implant stability relative micromotions between bone and implant were measured in relation to a cyclic torque of 7Nm applied on the longitudinal axis of the implant. We determined the fixation characteristics of the different implant designs by comparing these relative micromotions along the longitudinal stem axis. RESULTS: In the tested sawbones all studied implants showed sufficient primary stability to admit bone integration with relative micromotions below 150µm after adapting our results to physiologic hip joint loadings. Different fixation characteristics of the megaprostheses were determined, which could be explained by their differing design and fixation concepts. CONCLUSIONS: Cementless megaprostheses of different designs seem to provide sufficient primary stability to bridge proximal femoral defects if the diaphyseal isthmus is partially preserved. In our sawbone model the different implant fixation patterns can be related to their stem designs. No evidence can be provided to favor one of the studied implants in this setting. However, femoral morphology is variable and in different isthmus configurations specific implant designs might be appropriate to achieve the most favorable primary stability, which enables bone integration and consequently long term implant stability. Public Library of Science 2015-06-01 /pmc/articles/PMC4451245/ /pubmed/26030460 http://dx.doi.org/10.1371/journal.pone.0129149 Text en © 2015 Kinkel et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Kinkel, Stefan
Nadorf, Jan
Graage, Jan Dennis
Jakubowitz, Eike
Kretzer, Jan Philippe
Primary Rotational Stability of Various Megaprostheses in a Biomechanical Sawbone Model with Proximal Femoral Defects Extending to the Isthmus
title Primary Rotational Stability of Various Megaprostheses in a Biomechanical Sawbone Model with Proximal Femoral Defects Extending to the Isthmus
title_full Primary Rotational Stability of Various Megaprostheses in a Biomechanical Sawbone Model with Proximal Femoral Defects Extending to the Isthmus
title_fullStr Primary Rotational Stability of Various Megaprostheses in a Biomechanical Sawbone Model with Proximal Femoral Defects Extending to the Isthmus
title_full_unstemmed Primary Rotational Stability of Various Megaprostheses in a Biomechanical Sawbone Model with Proximal Femoral Defects Extending to the Isthmus
title_short Primary Rotational Stability of Various Megaprostheses in a Biomechanical Sawbone Model with Proximal Femoral Defects Extending to the Isthmus
title_sort primary rotational stability of various megaprostheses in a biomechanical sawbone model with proximal femoral defects extending to the isthmus
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4451245/
https://www.ncbi.nlm.nih.gov/pubmed/26030460
http://dx.doi.org/10.1371/journal.pone.0129149
work_keys_str_mv AT kinkelstefan primaryrotationalstabilityofvariousmegaprosthesesinabiomechanicalsawbonemodelwithproximalfemoraldefectsextendingtotheisthmus
AT nadorfjan primaryrotationalstabilityofvariousmegaprosthesesinabiomechanicalsawbonemodelwithproximalfemoraldefectsextendingtotheisthmus
AT graagejandennis primaryrotationalstabilityofvariousmegaprosthesesinabiomechanicalsawbonemodelwithproximalfemoraldefectsextendingtotheisthmus
AT jakubowitzeike primaryrotationalstabilityofvariousmegaprosthesesinabiomechanicalsawbonemodelwithproximalfemoraldefectsextendingtotheisthmus
AT kretzerjanphilippe primaryrotationalstabilityofvariousmegaprosthesesinabiomechanicalsawbonemodelwithproximalfemoraldefectsextendingtotheisthmus