Cargando…

Transection of a Coopdech bronchial blocker tip during bronchial resection for right upper lobectomy: a case report

A bronchial blocker (BB) is preferred for lung separation in patients with difficult airways. However, BBs, unlike double-lumen tubes, must be placed in the bronchus of the lung being operated on, hence can be damaged by surgical manipulation. Intubation was unexpectedly difficult in this male patie...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Yong-Hun, Yang, Hye Mo, Kim, Hyun-Chang, Bahk, Jae-Hyon, Seo, Jeong-Hwa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Anesthesiologists 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4452674/
https://www.ncbi.nlm.nih.gov/pubmed/26045933
http://dx.doi.org/10.4097/kjae.2015.68.3.287
_version_ 1782374337582465024
author Lee, Yong-Hun
Yang, Hye Mo
Kim, Hyun-Chang
Bahk, Jae-Hyon
Seo, Jeong-Hwa
author_facet Lee, Yong-Hun
Yang, Hye Mo
Kim, Hyun-Chang
Bahk, Jae-Hyon
Seo, Jeong-Hwa
author_sort Lee, Yong-Hun
collection PubMed
description A bronchial blocker (BB) is preferred for lung separation in patients with difficult airways. However, BBs, unlike double-lumen tubes, must be placed in the bronchus of the lung being operated on, hence can be damaged by surgical manipulation. Intubation was unexpectedly difficult in this male patient, so a Coopdech BB was placed in the right mainstem bronchus through a single-lumen tracheoscopic ventilation tube for a thoracoscopic right upper lobectomy. During the bronchial resection, however, the distal tip of the BB was transected and pinched in the staple line, so the staple line was partially opened, and the BB was withdrawn into the trachea. The opened bronchial stump was sutured manually under apnea without conversion to an open thoracotomy, and there was no significant air leakage through the suture line. This case underlines the importance of frequently evaluating the position of a BB during lung surgery.
format Online
Article
Text
id pubmed-4452674
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher The Korean Society of Anesthesiologists
record_format MEDLINE/PubMed
spelling pubmed-44526742015-06-04 Transection of a Coopdech bronchial blocker tip during bronchial resection for right upper lobectomy: a case report Lee, Yong-Hun Yang, Hye Mo Kim, Hyun-Chang Bahk, Jae-Hyon Seo, Jeong-Hwa Korean J Anesthesiol Case Report A bronchial blocker (BB) is preferred for lung separation in patients with difficult airways. However, BBs, unlike double-lumen tubes, must be placed in the bronchus of the lung being operated on, hence can be damaged by surgical manipulation. Intubation was unexpectedly difficult in this male patient, so a Coopdech BB was placed in the right mainstem bronchus through a single-lumen tracheoscopic ventilation tube for a thoracoscopic right upper lobectomy. During the bronchial resection, however, the distal tip of the BB was transected and pinched in the staple line, so the staple line was partially opened, and the BB was withdrawn into the trachea. The opened bronchial stump was sutured manually under apnea without conversion to an open thoracotomy, and there was no significant air leakage through the suture line. This case underlines the importance of frequently evaluating the position of a BB during lung surgery. The Korean Society of Anesthesiologists 2015-06 2015-05-28 /pmc/articles/PMC4452674/ /pubmed/26045933 http://dx.doi.org/10.4097/kjae.2015.68.3.287 Text en Copyright © the Korean Society of Anesthesiologists, 2015 http://creativecommons.org/licenses/by-nc/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Lee, Yong-Hun
Yang, Hye Mo
Kim, Hyun-Chang
Bahk, Jae-Hyon
Seo, Jeong-Hwa
Transection of a Coopdech bronchial blocker tip during bronchial resection for right upper lobectomy: a case report
title Transection of a Coopdech bronchial blocker tip during bronchial resection for right upper lobectomy: a case report
title_full Transection of a Coopdech bronchial blocker tip during bronchial resection for right upper lobectomy: a case report
title_fullStr Transection of a Coopdech bronchial blocker tip during bronchial resection for right upper lobectomy: a case report
title_full_unstemmed Transection of a Coopdech bronchial blocker tip during bronchial resection for right upper lobectomy: a case report
title_short Transection of a Coopdech bronchial blocker tip during bronchial resection for right upper lobectomy: a case report
title_sort transection of a coopdech bronchial blocker tip during bronchial resection for right upper lobectomy: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4452674/
https://www.ncbi.nlm.nih.gov/pubmed/26045933
http://dx.doi.org/10.4097/kjae.2015.68.3.287
work_keys_str_mv AT leeyonghun transectionofacoopdechbronchialblockertipduringbronchialresectionforrightupperlobectomyacasereport
AT yanghyemo transectionofacoopdechbronchialblockertipduringbronchialresectionforrightupperlobectomyacasereport
AT kimhyunchang transectionofacoopdechbronchialblockertipduringbronchialresectionforrightupperlobectomyacasereport
AT bahkjaehyon transectionofacoopdechbronchialblockertipduringbronchialresectionforrightupperlobectomyacasereport
AT seojeonghwa transectionofacoopdechbronchialblockertipduringbronchialresectionforrightupperlobectomyacasereport