Cargando…

Factors affecting the stability and repeatability of gamma camera calibration for quantitative imaging applications based on a retrospective review of clinical data

BACKGROUND: Absolute quantitative single-photon emission computed tomography (SPECT) has several important applications including monitoring tumor response after treatment and dose estimation for targeted radionuclide therapy treatment planning. Obtaining quantitative SPECT images in absolute activi...

Descripción completa

Detalles Bibliográficos
Autores principales: Anizan, Nadège, Wang, Hao, Zhou, Xian C, Hobbs, Robert F, Wahl, Richard L, Frey, Eric C
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4452683/
https://www.ncbi.nlm.nih.gov/pubmed/26116127
http://dx.doi.org/10.1186/s13550-014-0067-x
_version_ 1782374339721560064
author Anizan, Nadège
Wang, Hao
Zhou, Xian C
Hobbs, Robert F
Wahl, Richard L
Frey, Eric C
author_facet Anizan, Nadège
Wang, Hao
Zhou, Xian C
Hobbs, Robert F
Wahl, Richard L
Frey, Eric C
author_sort Anizan, Nadège
collection PubMed
description BACKGROUND: Absolute quantitative single-photon emission computed tomography (SPECT) has several important applications including monitoring tumor response after treatment and dose estimation for targeted radionuclide therapy treatment planning. Obtaining quantitative SPECT images in absolute activity units requires the use of a calibration factor, and the repeatability of this directly affects the repeatability of image quantification. This study focused on evaluating the factors affecting the repeatability of a calibration factor measured using a planar image of an in-air calibration source. METHODS: The calibration factors calculated as part of (131)I-tositumomab patient dosimetry scans used in treatment planning performed over a 4-year period were retrospectively analyzed. Raw data included total counts in whole-body images of a radioactive calibration source, the activity of the source measured in a radionuclide activity meter (often referred to as a dose calibrator), and the background count rate obtained at three time points for each patient. The count rate from extrinsic flood source acquisitions and radionuclide activity meter constancy obtained on the same day as each image were also used. The data were analyzed statistically using a mixed-effects model to determine the factors affecting variations in the measured calibration factors. RESULTS: The global variability in the calibration factor was equal to 2.3% and was decreased by 20% to 1.8%, when the decay-corrected measurements of calibration source activity were averaged over the three time points for each patient. Camera sensitivity variation measured using a (57)Co sheet source was small and had a weak relationship to calibration factor variations. When the averaged source activity was used, the main source of variance was related to preparation and measurement of the source (77%). Radionuclide activity meter constancy had a smaller but statistically significant impact on the calibration factor. CONCLUSIONS: This study indicates that calibration factors based on planar measurements have good reproducibility. The findings of this study indicate (1) the importance of accurate and precise preparation and measurement of the calibration source activity, (2) the need to carefully control background activity during calibration factor assessment and patient data acquisition, and (3) that the calibration factor and camera sensitivity were stable over time, indicating that careful but less frequent calibration is needed.
format Online
Article
Text
id pubmed-4452683
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-44526832015-06-09 Factors affecting the stability and repeatability of gamma camera calibration for quantitative imaging applications based on a retrospective review of clinical data Anizan, Nadège Wang, Hao Zhou, Xian C Hobbs, Robert F Wahl, Richard L Frey, Eric C EJNMMI Res Original Research BACKGROUND: Absolute quantitative single-photon emission computed tomography (SPECT) has several important applications including monitoring tumor response after treatment and dose estimation for targeted radionuclide therapy treatment planning. Obtaining quantitative SPECT images in absolute activity units requires the use of a calibration factor, and the repeatability of this directly affects the repeatability of image quantification. This study focused on evaluating the factors affecting the repeatability of a calibration factor measured using a planar image of an in-air calibration source. METHODS: The calibration factors calculated as part of (131)I-tositumomab patient dosimetry scans used in treatment planning performed over a 4-year period were retrospectively analyzed. Raw data included total counts in whole-body images of a radioactive calibration source, the activity of the source measured in a radionuclide activity meter (often referred to as a dose calibrator), and the background count rate obtained at three time points for each patient. The count rate from extrinsic flood source acquisitions and radionuclide activity meter constancy obtained on the same day as each image were also used. The data were analyzed statistically using a mixed-effects model to determine the factors affecting variations in the measured calibration factors. RESULTS: The global variability in the calibration factor was equal to 2.3% and was decreased by 20% to 1.8%, when the decay-corrected measurements of calibration source activity were averaged over the three time points for each patient. Camera sensitivity variation measured using a (57)Co sheet source was small and had a weak relationship to calibration factor variations. When the averaged source activity was used, the main source of variance was related to preparation and measurement of the source (77%). Radionuclide activity meter constancy had a smaller but statistically significant impact on the calibration factor. CONCLUSIONS: This study indicates that calibration factors based on planar measurements have good reproducibility. The findings of this study indicate (1) the importance of accurate and precise preparation and measurement of the calibration source activity, (2) the need to carefully control background activity during calibration factor assessment and patient data acquisition, and (3) that the calibration factor and camera sensitivity were stable over time, indicating that careful but less frequent calibration is needed. Springer Berlin Heidelberg 2014-12-16 /pmc/articles/PMC4452683/ /pubmed/26116127 http://dx.doi.org/10.1186/s13550-014-0067-x Text en © Anizan et al.; licensee Springer. 2014 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited.
spellingShingle Original Research
Anizan, Nadège
Wang, Hao
Zhou, Xian C
Hobbs, Robert F
Wahl, Richard L
Frey, Eric C
Factors affecting the stability and repeatability of gamma camera calibration for quantitative imaging applications based on a retrospective review of clinical data
title Factors affecting the stability and repeatability of gamma camera calibration for quantitative imaging applications based on a retrospective review of clinical data
title_full Factors affecting the stability and repeatability of gamma camera calibration for quantitative imaging applications based on a retrospective review of clinical data
title_fullStr Factors affecting the stability and repeatability of gamma camera calibration for quantitative imaging applications based on a retrospective review of clinical data
title_full_unstemmed Factors affecting the stability and repeatability of gamma camera calibration for quantitative imaging applications based on a retrospective review of clinical data
title_short Factors affecting the stability and repeatability of gamma camera calibration for quantitative imaging applications based on a retrospective review of clinical data
title_sort factors affecting the stability and repeatability of gamma camera calibration for quantitative imaging applications based on a retrospective review of clinical data
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4452683/
https://www.ncbi.nlm.nih.gov/pubmed/26116127
http://dx.doi.org/10.1186/s13550-014-0067-x
work_keys_str_mv AT anizannadege factorsaffectingthestabilityandrepeatabilityofgammacameracalibrationforquantitativeimagingapplicationsbasedonaretrospectivereviewofclinicaldata
AT wanghao factorsaffectingthestabilityandrepeatabilityofgammacameracalibrationforquantitativeimagingapplicationsbasedonaretrospectivereviewofclinicaldata
AT zhouxianc factorsaffectingthestabilityandrepeatabilityofgammacameracalibrationforquantitativeimagingapplicationsbasedonaretrospectivereviewofclinicaldata
AT hobbsrobertf factorsaffectingthestabilityandrepeatabilityofgammacameracalibrationforquantitativeimagingapplicationsbasedonaretrospectivereviewofclinicaldata
AT wahlrichardl factorsaffectingthestabilityandrepeatabilityofgammacameracalibrationforquantitativeimagingapplicationsbasedonaretrospectivereviewofclinicaldata
AT freyericc factorsaffectingthestabilityandrepeatabilityofgammacameracalibrationforquantitativeimagingapplicationsbasedonaretrospectivereviewofclinicaldata