Cargando…

Guaiac faecal occult blood test performance at initial and repeat screens in the English Bowel Cancer Screening Programme

BACKGROUND: In many countries, screening for colorectal cancer (CRC) relies on repeat testing using the guaiac faecal occult blood test (gFOBT). This study aimed to compare gFOBT performance measures between initial and repeat screens. METHODS: Data on screening uptake and outcomes from the English...

Descripción completa

Detalles Bibliográficos
Autores principales: Kearns, B, Whyte, S, Chilcott, J, Patnick, J
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4453729/
https://www.ncbi.nlm.nih.gov/pubmed/25180767
http://dx.doi.org/10.1038/bjc.2014.469
_version_ 1782374506017325056
author Kearns, B
Whyte, S
Chilcott, J
Patnick, J
author_facet Kearns, B
Whyte, S
Chilcott, J
Patnick, J
author_sort Kearns, B
collection PubMed
description BACKGROUND: In many countries, screening for colorectal cancer (CRC) relies on repeat testing using the guaiac faecal occult blood test (gFOBT). This study aimed to compare gFOBT performance measures between initial and repeat screens. METHODS: Data on screening uptake and outcomes from the English Bowel Cancer Screening Programme (BCSP) for the years 2008 and 2011 were used. An existing CRC natural history model was used to estimate gFOBT sensitivity and specificity, and the cost-effectiveness of different screening strategies. RESULTS: The gFOBT sensitivity for CRC was estimated to decrease from 27.35% at the initial screen to 20.22% at the repeat screen. Decreases were also observed for the positive predictive value (8.4–7.2%) and detection rate for CRC (0.19–0.14%). Assuming equal performance measures for both the initial and repeat screens led to an overestimate of the cost effectiveness of gFOBT screening compared with the other screening modalities. CONCLUSIONS: Performance measures for gFOBT screening were generally lower in the repeat screen compared with the initial screen. Screening for CRC using gFOBT is likely to be cost-effective; however, the use of different screening modalities may result in additional benefits. Future economic evaluations of gFOBT should not assume equal sensitivities between screening rounds.
format Online
Article
Text
id pubmed-4453729
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Nature Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-44537292015-10-28 Guaiac faecal occult blood test performance at initial and repeat screens in the English Bowel Cancer Screening Programme Kearns, B Whyte, S Chilcott, J Patnick, J Br J Cancer Clinical Study BACKGROUND: In many countries, screening for colorectal cancer (CRC) relies on repeat testing using the guaiac faecal occult blood test (gFOBT). This study aimed to compare gFOBT performance measures between initial and repeat screens. METHODS: Data on screening uptake and outcomes from the English Bowel Cancer Screening Programme (BCSP) for the years 2008 and 2011 were used. An existing CRC natural history model was used to estimate gFOBT sensitivity and specificity, and the cost-effectiveness of different screening strategies. RESULTS: The gFOBT sensitivity for CRC was estimated to decrease from 27.35% at the initial screen to 20.22% at the repeat screen. Decreases were also observed for the positive predictive value (8.4–7.2%) and detection rate for CRC (0.19–0.14%). Assuming equal performance measures for both the initial and repeat screens led to an overestimate of the cost effectiveness of gFOBT screening compared with the other screening modalities. CONCLUSIONS: Performance measures for gFOBT screening were generally lower in the repeat screen compared with the initial screen. Screening for CRC using gFOBT is likely to be cost-effective; however, the use of different screening modalities may result in additional benefits. Future economic evaluations of gFOBT should not assume equal sensitivities between screening rounds. Nature Publishing Group 2014-10-28 2014-09-02 /pmc/articles/PMC4453729/ /pubmed/25180767 http://dx.doi.org/10.1038/bjc.2014.469 Text en Copyright © 2014 Cancer Research UK http://creativecommons.org/licenses/by-nc-sa/3.0/ From twelve months after its original publication, this work is licensed under the Creative Commons Attribution-NonCommercial-Share Alike 3.0 Unported License. To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-sa/3.0/
spellingShingle Clinical Study
Kearns, B
Whyte, S
Chilcott, J
Patnick, J
Guaiac faecal occult blood test performance at initial and repeat screens in the English Bowel Cancer Screening Programme
title Guaiac faecal occult blood test performance at initial and repeat screens in the English Bowel Cancer Screening Programme
title_full Guaiac faecal occult blood test performance at initial and repeat screens in the English Bowel Cancer Screening Programme
title_fullStr Guaiac faecal occult blood test performance at initial and repeat screens in the English Bowel Cancer Screening Programme
title_full_unstemmed Guaiac faecal occult blood test performance at initial and repeat screens in the English Bowel Cancer Screening Programme
title_short Guaiac faecal occult blood test performance at initial and repeat screens in the English Bowel Cancer Screening Programme
title_sort guaiac faecal occult blood test performance at initial and repeat screens in the english bowel cancer screening programme
topic Clinical Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4453729/
https://www.ncbi.nlm.nih.gov/pubmed/25180767
http://dx.doi.org/10.1038/bjc.2014.469
work_keys_str_mv AT kearnsb guaiacfaecaloccultbloodtestperformanceatinitialandrepeatscreensintheenglishbowelcancerscreeningprogramme
AT whytes guaiacfaecaloccultbloodtestperformanceatinitialandrepeatscreensintheenglishbowelcancerscreeningprogramme
AT chilcottj guaiacfaecaloccultbloodtestperformanceatinitialandrepeatscreensintheenglishbowelcancerscreeningprogramme
AT patnickj guaiacfaecaloccultbloodtestperformanceatinitialandrepeatscreensintheenglishbowelcancerscreeningprogramme