Cargando…

Reference point detection for camera-based fingerprint image based on wavelet transformation

BACKGROUND: Fingerprint recognition systems essentially require core-point detection prior to fingerprint matching. The core-point is used as a reference point to align the fingerprint with a template database. When processing a larger fingerprint database, it is necessary to consider the core-point...

Descripción completa

Detalles Bibliográficos
Autor principal: Khalil, Mohammed S
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4455976/
https://www.ncbi.nlm.nih.gov/pubmed/25925774
http://dx.doi.org/10.1186/s12938-015-0029-1
_version_ 1782374790444613632
author Khalil, Mohammed S
author_facet Khalil, Mohammed S
author_sort Khalil, Mohammed S
collection PubMed
description BACKGROUND: Fingerprint recognition systems essentially require core-point detection prior to fingerprint matching. The core-point is used as a reference point to align the fingerprint with a template database. When processing a larger fingerprint database, it is necessary to consider the core-point during feature extraction. Numerous core-point detection methods are available and have been reported in the literature. However, these methods are generally applied to scanner-based images. Hence, this paper attempts to explore the feasibility of applying a core-point detection method to a fingerprint image obtained using a camera phone. METHOD: The proposed method utilizes a discrete wavelet transform to extract the ridge information from a color image. The performance of proposed method is evaluated in terms of accuracy and consistency. These two indicators are calculated automatically by comparing the method’s output with the defined core points. RESULTS: The proposed method is tested on two data sets, controlled and uncontrolled environment, collected from 13 different subjects. In the controlled environment, the proposed method achieved a detection rate 82.98%. In uncontrolled environment, the proposed method yield a detection rate of 78.21%. CONCLUSION: The proposed method yields promising results in a collected-image database. Moreover, the proposed method outperformed compare to existing method.
format Online
Article
Text
id pubmed-4455976
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-44559762015-06-05 Reference point detection for camera-based fingerprint image based on wavelet transformation Khalil, Mohammed S Biomed Eng Online Research BACKGROUND: Fingerprint recognition systems essentially require core-point detection prior to fingerprint matching. The core-point is used as a reference point to align the fingerprint with a template database. When processing a larger fingerprint database, it is necessary to consider the core-point during feature extraction. Numerous core-point detection methods are available and have been reported in the literature. However, these methods are generally applied to scanner-based images. Hence, this paper attempts to explore the feasibility of applying a core-point detection method to a fingerprint image obtained using a camera phone. METHOD: The proposed method utilizes a discrete wavelet transform to extract the ridge information from a color image. The performance of proposed method is evaluated in terms of accuracy and consistency. These two indicators are calculated automatically by comparing the method’s output with the defined core points. RESULTS: The proposed method is tested on two data sets, controlled and uncontrolled environment, collected from 13 different subjects. In the controlled environment, the proposed method achieved a detection rate 82.98%. In uncontrolled environment, the proposed method yield a detection rate of 78.21%. CONCLUSION: The proposed method yields promising results in a collected-image database. Moreover, the proposed method outperformed compare to existing method. BioMed Central 2015-04-30 /pmc/articles/PMC4455976/ /pubmed/25925774 http://dx.doi.org/10.1186/s12938-015-0029-1 Text en © Khalil; licensee BioMed Central. 2015 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Khalil, Mohammed S
Reference point detection for camera-based fingerprint image based on wavelet transformation
title Reference point detection for camera-based fingerprint image based on wavelet transformation
title_full Reference point detection for camera-based fingerprint image based on wavelet transformation
title_fullStr Reference point detection for camera-based fingerprint image based on wavelet transformation
title_full_unstemmed Reference point detection for camera-based fingerprint image based on wavelet transformation
title_short Reference point detection for camera-based fingerprint image based on wavelet transformation
title_sort reference point detection for camera-based fingerprint image based on wavelet transformation
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4455976/
https://www.ncbi.nlm.nih.gov/pubmed/25925774
http://dx.doi.org/10.1186/s12938-015-0029-1
work_keys_str_mv AT khalilmohammeds referencepointdetectionforcamerabasedfingerprintimagebasedonwavelettransformation