A comparative evaluation of the marginal accuracy of crowns fabricated from four commercially available provisional materials: An in vitro study

PURPOSE: The purpose of this in vitro study was to evaluate and compare the primary marginal accuracy of four commercially available provisional materials (Protemp 4, Luxatemp Star, Visalys Temp and DPI tooth moulding powder and liquid) at 2 time intervals (10 and 30 min). MATERIALS AND METHODS: A c...

Descripción completa

Detalles Bibliográficos
Autores principales: Amin, Bhavya Mohandas, Aras, Meena Ajay, Chitre, Vidya
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4456735/
https://www.ncbi.nlm.nih.gov/pubmed/26097348
http://dx.doi.org/10.4103/0976-237X.156035
_version_ 1782374874378928128
author Amin, Bhavya Mohandas
Aras, Meena Ajay
Chitre, Vidya
author_facet Amin, Bhavya Mohandas
Aras, Meena Ajay
Chitre, Vidya
author_sort Amin, Bhavya Mohandas
collection PubMed
description PURPOSE: The purpose of this in vitro study was to evaluate and compare the primary marginal accuracy of four commercially available provisional materials (Protemp 4, Luxatemp Star, Visalys Temp and DPI tooth moulding powder and liquid) at 2 time intervals (10 and 30 min). MATERIALS AND METHODS: A customized stainless steel master model containing two interchangeable dies was used for fabrication of provisional crowns. Forty crowns (n = 10) were fabricated, and each crown was evaluated under a stereomicroscope. Vertical marginal discrepancies were noted and compared at 10 min since the start of mixing and then at 30 min. OBSERVATIONS AND RESULTS: Protemp 4 showed the least vertical marginal discrepancy (71.59 μ), followed by Luxatemp Star (91.93 μ) at 10 min. DPI showed a marginal discrepancy of 95.94 μ while Visalys Temp crowns had vertical marginal discrepancy of 106.81 μ. There was a significant difference in the marginal discrepancy values of Protemp 4 and Visalys Temp. At 30 min, there was a significant difference between the marginal discrepancy of Protemp 4 crowns (83.11 μ) and Visalys Temp crowns (128.97 μ) and between Protemp 4 and DPI (118.88 μ). No significant differences were observed between Protemp 4 and Luxatemp Star. CONCLUSION: The vertical marginal discrepancy of temporary crowns fabricated from the four commercially available provisional materials ranged from 71 to 106 μ immediately after fabrication (at 10 min from the start of mix) to 83–128 μ (30 min from the start of mix). The time elapsed after mixing had a significant influence on the marginal accuracy of the crowns.
format Online
Article
Text
id pubmed-4456735
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-44567352015-06-19 A comparative evaluation of the marginal accuracy of crowns fabricated from four commercially available provisional materials: An in vitro study Amin, Bhavya Mohandas Aras, Meena Ajay Chitre, Vidya Contemp Clin Dent Original Article PURPOSE: The purpose of this in vitro study was to evaluate and compare the primary marginal accuracy of four commercially available provisional materials (Protemp 4, Luxatemp Star, Visalys Temp and DPI tooth moulding powder and liquid) at 2 time intervals (10 and 30 min). MATERIALS AND METHODS: A customized stainless steel master model containing two interchangeable dies was used for fabrication of provisional crowns. Forty crowns (n = 10) were fabricated, and each crown was evaluated under a stereomicroscope. Vertical marginal discrepancies were noted and compared at 10 min since the start of mixing and then at 30 min. OBSERVATIONS AND RESULTS: Protemp 4 showed the least vertical marginal discrepancy (71.59 μ), followed by Luxatemp Star (91.93 μ) at 10 min. DPI showed a marginal discrepancy of 95.94 μ while Visalys Temp crowns had vertical marginal discrepancy of 106.81 μ. There was a significant difference in the marginal discrepancy values of Protemp 4 and Visalys Temp. At 30 min, there was a significant difference between the marginal discrepancy of Protemp 4 crowns (83.11 μ) and Visalys Temp crowns (128.97 μ) and between Protemp 4 and DPI (118.88 μ). No significant differences were observed between Protemp 4 and Luxatemp Star. CONCLUSION: The vertical marginal discrepancy of temporary crowns fabricated from the four commercially available provisional materials ranged from 71 to 106 μ immediately after fabrication (at 10 min from the start of mix) to 83–128 μ (30 min from the start of mix). The time elapsed after mixing had a significant influence on the marginal accuracy of the crowns. Medknow Publications & Media Pvt Ltd 2015 /pmc/articles/PMC4456735/ /pubmed/26097348 http://dx.doi.org/10.4103/0976-237X.156035 Text en Copyright: © Contemporary Clinical Dentistry http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Amin, Bhavya Mohandas
Aras, Meena Ajay
Chitre, Vidya
A comparative evaluation of the marginal accuracy of crowns fabricated from four commercially available provisional materials: An in vitro study
title A comparative evaluation of the marginal accuracy of crowns fabricated from four commercially available provisional materials: An in vitro study
title_full A comparative evaluation of the marginal accuracy of crowns fabricated from four commercially available provisional materials: An in vitro study
title_fullStr A comparative evaluation of the marginal accuracy of crowns fabricated from four commercially available provisional materials: An in vitro study
title_full_unstemmed A comparative evaluation of the marginal accuracy of crowns fabricated from four commercially available provisional materials: An in vitro study
title_short A comparative evaluation of the marginal accuracy of crowns fabricated from four commercially available provisional materials: An in vitro study
title_sort comparative evaluation of the marginal accuracy of crowns fabricated from four commercially available provisional materials: an in vitro study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4456735/
https://www.ncbi.nlm.nih.gov/pubmed/26097348
http://dx.doi.org/10.4103/0976-237X.156035
work_keys_str_mv AT aminbhavyamohandas acomparativeevaluationofthemarginalaccuracyofcrownsfabricatedfromfourcommerciallyavailableprovisionalmaterialsaninvitrostudy
AT arasmeenaajay acomparativeevaluationofthemarginalaccuracyofcrownsfabricatedfromfourcommerciallyavailableprovisionalmaterialsaninvitrostudy
AT chitrevidya acomparativeevaluationofthemarginalaccuracyofcrownsfabricatedfromfourcommerciallyavailableprovisionalmaterialsaninvitrostudy
AT aminbhavyamohandas comparativeevaluationofthemarginalaccuracyofcrownsfabricatedfromfourcommerciallyavailableprovisionalmaterialsaninvitrostudy
AT arasmeenaajay comparativeevaluationofthemarginalaccuracyofcrownsfabricatedfromfourcommerciallyavailableprovisionalmaterialsaninvitrostudy
AT chitrevidya comparativeevaluationofthemarginalaccuracyofcrownsfabricatedfromfourcommerciallyavailableprovisionalmaterialsaninvitrostudy