Cargando…

Reliability and reproducibility of spectral and time domain optical coherence tomography images before and after correction for patients with age-related macular degeneration

Purpose: To evaluate the reproducibility and reliability of optical coherence tomography scans obtained using the time domain (TD-OCT) Stratus (TM) OCT, and the Spectral Domain (SD-OCT) Spectralis (TM) and Cirrus (TM) OCT devices before and after manual correction in eyes with either Neovascular (NV...

Descripción completa

Detalles Bibliográficos
Autores principales: Sadiq, Mohammad A., Rashid, Aymen, Channa, Roomasa, Hatef, Elham, Do, Diana V, Nguyen, Quan Dong, Sepah, Yasir J
Formato: Online Artículo Texto
Lenguaje:English
Publicado: F1000Research 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4457115/
https://www.ncbi.nlm.nih.gov/pubmed/26097682
http://dx.doi.org/10.12688/f1000research.2-131.v2
_version_ 1782374940540928000
author Sadiq, Mohammad A.
Rashid, Aymen
Channa, Roomasa
Hatef, Elham
Do, Diana V
Nguyen, Quan Dong
Sepah, Yasir J
author_facet Sadiq, Mohammad A.
Rashid, Aymen
Channa, Roomasa
Hatef, Elham
Do, Diana V
Nguyen, Quan Dong
Sepah, Yasir J
author_sort Sadiq, Mohammad A.
collection PubMed
description Purpose: To evaluate the reproducibility and reliability of optical coherence tomography scans obtained using the time domain (TD-OCT) Stratus (TM) OCT, and the Spectral Domain (SD-OCT) Spectralis (TM) and Cirrus (TM) OCT devices before and after manual correction in eyes with either Neovascular (NV-AMD) or Non-Neovascular (NNV-AMD) age-related macular degeneration. Design: Prospective observational study. Methods: Setting: University-based retina practice. Patients: Thirty-six patients (50 eyes) with NV-AMD or NNV-AMD. Procedure: OCT scans were taken simultaneously using one TD-OCT and two SD-OCT devices. Main Outcome Measures: Macular thickness measurements were assessed before and after correction of the algorithm by constructing Bland-Altman plots for agreement and calculating intraclass correlation coefficients (ICCs) and coefficients of repeatability (COR) to evaluate intraclass repeatability. Results: Spectralis had the highest number of images needing manual correction.  All machines had high ICCs, with Spectralis having the highest.  Also, Bland-Altman plots indicated that there was low agreement between Cirrus™ and Stratus™, Spectralis™ and Stratus™, while there was good agreement between the Cirrus™ and Spectralis™.  The CORs were lowest for Spectralis (TM )and similar and higher for Cirrus (TM )and Stratus (TM).  Agreement, CORs, and ICCs generally improved after manual correction, but only minimally.  Conclusion: Agreement is low between devices, except between both SD-OCT machines.  Manual correction tends to improve results.
format Online
Article
Text
id pubmed-4457115
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher F1000Research
record_format MEDLINE/PubMed
spelling pubmed-44571152015-06-19 Reliability and reproducibility of spectral and time domain optical coherence tomography images before and after correction for patients with age-related macular degeneration Sadiq, Mohammad A. Rashid, Aymen Channa, Roomasa Hatef, Elham Do, Diana V Nguyen, Quan Dong Sepah, Yasir J F1000Res Research Article Purpose: To evaluate the reproducibility and reliability of optical coherence tomography scans obtained using the time domain (TD-OCT) Stratus (TM) OCT, and the Spectral Domain (SD-OCT) Spectralis (TM) and Cirrus (TM) OCT devices before and after manual correction in eyes with either Neovascular (NV-AMD) or Non-Neovascular (NNV-AMD) age-related macular degeneration. Design: Prospective observational study. Methods: Setting: University-based retina practice. Patients: Thirty-six patients (50 eyes) with NV-AMD or NNV-AMD. Procedure: OCT scans were taken simultaneously using one TD-OCT and two SD-OCT devices. Main Outcome Measures: Macular thickness measurements were assessed before and after correction of the algorithm by constructing Bland-Altman plots for agreement and calculating intraclass correlation coefficients (ICCs) and coefficients of repeatability (COR) to evaluate intraclass repeatability. Results: Spectralis had the highest number of images needing manual correction.  All machines had high ICCs, with Spectralis having the highest.  Also, Bland-Altman plots indicated that there was low agreement between Cirrus™ and Stratus™, Spectralis™ and Stratus™, while there was good agreement between the Cirrus™ and Spectralis™.  The CORs were lowest for Spectralis (TM )and similar and higher for Cirrus (TM )and Stratus (TM).  Agreement, CORs, and ICCs generally improved after manual correction, but only minimally.  Conclusion: Agreement is low between devices, except between both SD-OCT machines.  Manual correction tends to improve results. F1000Research 2015-03-05 /pmc/articles/PMC4457115/ /pubmed/26097682 http://dx.doi.org/10.12688/f1000research.2-131.v2 Text en Copyright: © 2015 Sadiq MA et al. http://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the terms of the Creative Commons Attribution Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. http://creativecommons.org/publicdomain/zero/1.0/ Data associated with the article are available under the terms of the Creative Commons Zero "No rights reserved" data waiver (CC0 1.0 Public domain dedication).
spellingShingle Research Article
Sadiq, Mohammad A.
Rashid, Aymen
Channa, Roomasa
Hatef, Elham
Do, Diana V
Nguyen, Quan Dong
Sepah, Yasir J
Reliability and reproducibility of spectral and time domain optical coherence tomography images before and after correction for patients with age-related macular degeneration
title Reliability and reproducibility of spectral and time domain optical coherence tomography images before and after correction for patients with age-related macular degeneration
title_full Reliability and reproducibility of spectral and time domain optical coherence tomography images before and after correction for patients with age-related macular degeneration
title_fullStr Reliability and reproducibility of spectral and time domain optical coherence tomography images before and after correction for patients with age-related macular degeneration
title_full_unstemmed Reliability and reproducibility of spectral and time domain optical coherence tomography images before and after correction for patients with age-related macular degeneration
title_short Reliability and reproducibility of spectral and time domain optical coherence tomography images before and after correction for patients with age-related macular degeneration
title_sort reliability and reproducibility of spectral and time domain optical coherence tomography images before and after correction for patients with age-related macular degeneration
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4457115/
https://www.ncbi.nlm.nih.gov/pubmed/26097682
http://dx.doi.org/10.12688/f1000research.2-131.v2
work_keys_str_mv AT sadiqmohammada reliabilityandreproducibilityofspectralandtimedomainopticalcoherencetomographyimagesbeforeandaftercorrectionforpatientswithagerelatedmaculardegeneration
AT rashidaymen reliabilityandreproducibilityofspectralandtimedomainopticalcoherencetomographyimagesbeforeandaftercorrectionforpatientswithagerelatedmaculardegeneration
AT channaroomasa reliabilityandreproducibilityofspectralandtimedomainopticalcoherencetomographyimagesbeforeandaftercorrectionforpatientswithagerelatedmaculardegeneration
AT hatefelham reliabilityandreproducibilityofspectralandtimedomainopticalcoherencetomographyimagesbeforeandaftercorrectionforpatientswithagerelatedmaculardegeneration
AT dodianav reliabilityandreproducibilityofspectralandtimedomainopticalcoherencetomographyimagesbeforeandaftercorrectionforpatientswithagerelatedmaculardegeneration
AT nguyenquandong reliabilityandreproducibilityofspectralandtimedomainopticalcoherencetomographyimagesbeforeandaftercorrectionforpatientswithagerelatedmaculardegeneration
AT sepahyasirj reliabilityandreproducibilityofspectralandtimedomainopticalcoherencetomographyimagesbeforeandaftercorrectionforpatientswithagerelatedmaculardegeneration