Cargando…
Evaluation of hemoglobin performance in the assessment of iron stores in feto-maternal pairs in a high-risk population: receiver operating characteristic curve analysis
OBJECTIVE: By applying receiver operating characteristic curve analysis, the objective of this study was to see whether hemoglobin levels reflect body iron stores in a group of pregnant women at term who, by using serum ferritin as the reference test, had a high pre-test probability of having iron d...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Sociedade Brasileira de Hematologia e Hemoterapia
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4459433/ https://www.ncbi.nlm.nih.gov/pubmed/26041420 http://dx.doi.org/10.1016/j.bjhh.2015.02.002 |
_version_ | 1782375220751892480 |
---|---|
author | Jaime-Pérez, José Carlos García-Arellano, Gisela Méndez-Ramírez, Nereida González-Llano, Óscar Gómez-Almaguer, David |
author_facet | Jaime-Pérez, José Carlos García-Arellano, Gisela Méndez-Ramírez, Nereida González-Llano, Óscar Gómez-Almaguer, David |
author_sort | Jaime-Pérez, José Carlos |
collection | PubMed |
description | OBJECTIVE: By applying receiver operating characteristic curve analysis, the objective of this study was to see whether hemoglobin levels reflect body iron stores in a group of pregnant women at term who, by using serum ferritin as the reference test, had a high pre-test probability of having iron deficiency anemia. Likewise, we evaluated the ability of hemoglobin and maternal serum ferritin levels to predict iron deficiency anemia in newborns. METHODS: Hemoglobin and serum ferritin were measured in 187 pregnant women at term belonging to a group with a high pre-test probability of iron deficiency anemia and their newborns. Women with Hb <11.0 g/dL and newborns with cord Hb <13.0 g/dL were classified as anemic. A serum ferritin <12.0 μg/L in women and a cord blood serum ferritin <35.0 μg/L were considered to reflect empty iron stores. Receiver operating characteristic curve analysis was applied to select the cut-off points that better reflected iron stores. RESULTS: The Hb cut-off point selected by receiver operating characteristic curve analysis in women was <11.5 g/dL (sensitivity: 60.82, specificity: 53.33%, Youden Index: 0.450). Most of the newborns had normal Hb which precluded this analysis. Maternal Hb <11.0 g/dL was the cut-off point that best reflected iron deficiency anemia in newborns (sensitivity: 55.88%, specificity: 57.24%, Youden Index: 0.217). The best cut-off point of maternal serum ferritin to reflect empty iron stores in newborns was <6.0 μg/L (sensitivity: 76.47%, specificity: 31.58%, Youden Index: 0.200). CONCLUSION: Hemoglobin concentration performed poorly to detect iron deficiency anemia in women at term with high risk for iron deficiency and their newborns. |
format | Online Article Text |
id | pubmed-4459433 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Sociedade Brasileira de Hematologia e Hemoterapia |
record_format | MEDLINE/PubMed |
spelling | pubmed-44594332015-06-16 Evaluation of hemoglobin performance in the assessment of iron stores in feto-maternal pairs in a high-risk population: receiver operating characteristic curve analysis Jaime-Pérez, José Carlos García-Arellano, Gisela Méndez-Ramírez, Nereida González-Llano, Óscar Gómez-Almaguer, David Rev Bras Hematol Hemoter Original Article OBJECTIVE: By applying receiver operating characteristic curve analysis, the objective of this study was to see whether hemoglobin levels reflect body iron stores in a group of pregnant women at term who, by using serum ferritin as the reference test, had a high pre-test probability of having iron deficiency anemia. Likewise, we evaluated the ability of hemoglobin and maternal serum ferritin levels to predict iron deficiency anemia in newborns. METHODS: Hemoglobin and serum ferritin were measured in 187 pregnant women at term belonging to a group with a high pre-test probability of iron deficiency anemia and their newborns. Women with Hb <11.0 g/dL and newborns with cord Hb <13.0 g/dL were classified as anemic. A serum ferritin <12.0 μg/L in women and a cord blood serum ferritin <35.0 μg/L were considered to reflect empty iron stores. Receiver operating characteristic curve analysis was applied to select the cut-off points that better reflected iron stores. RESULTS: The Hb cut-off point selected by receiver operating characteristic curve analysis in women was <11.5 g/dL (sensitivity: 60.82, specificity: 53.33%, Youden Index: 0.450). Most of the newborns had normal Hb which precluded this analysis. Maternal Hb <11.0 g/dL was the cut-off point that best reflected iron deficiency anemia in newborns (sensitivity: 55.88%, specificity: 57.24%, Youden Index: 0.217). The best cut-off point of maternal serum ferritin to reflect empty iron stores in newborns was <6.0 μg/L (sensitivity: 76.47%, specificity: 31.58%, Youden Index: 0.200). CONCLUSION: Hemoglobin concentration performed poorly to detect iron deficiency anemia in women at term with high risk for iron deficiency and their newborns. Sociedade Brasileira de Hematologia e Hemoterapia 2015 2015-02-17 /pmc/articles/PMC4459433/ /pubmed/26041420 http://dx.doi.org/10.1016/j.bjhh.2015.02.002 Text en © 2015 Associação Brasileira de Hematologia, Hemoterapia e Terapia Celular. Published by Elsevier Editora Ltda. All rights reserved. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Article Jaime-Pérez, José Carlos García-Arellano, Gisela Méndez-Ramírez, Nereida González-Llano, Óscar Gómez-Almaguer, David Evaluation of hemoglobin performance in the assessment of iron stores in feto-maternal pairs in a high-risk population: receiver operating characteristic curve analysis |
title | Evaluation of hemoglobin performance in the assessment of iron stores in feto-maternal pairs in a high-risk population: receiver operating characteristic curve analysis |
title_full | Evaluation of hemoglobin performance in the assessment of iron stores in feto-maternal pairs in a high-risk population: receiver operating characteristic curve analysis |
title_fullStr | Evaluation of hemoglobin performance in the assessment of iron stores in feto-maternal pairs in a high-risk population: receiver operating characteristic curve analysis |
title_full_unstemmed | Evaluation of hemoglobin performance in the assessment of iron stores in feto-maternal pairs in a high-risk population: receiver operating characteristic curve analysis |
title_short | Evaluation of hemoglobin performance in the assessment of iron stores in feto-maternal pairs in a high-risk population: receiver operating characteristic curve analysis |
title_sort | evaluation of hemoglobin performance in the assessment of iron stores in feto-maternal pairs in a high-risk population: receiver operating characteristic curve analysis |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4459433/ https://www.ncbi.nlm.nih.gov/pubmed/26041420 http://dx.doi.org/10.1016/j.bjhh.2015.02.002 |
work_keys_str_mv | AT jaimeperezjosecarlos evaluationofhemoglobinperformanceintheassessmentofironstoresinfetomaternalpairsinahighriskpopulationreceiveroperatingcharacteristiccurveanalysis AT garciaarellanogisela evaluationofhemoglobinperformanceintheassessmentofironstoresinfetomaternalpairsinahighriskpopulationreceiveroperatingcharacteristiccurveanalysis AT mendezramireznereida evaluationofhemoglobinperformanceintheassessmentofironstoresinfetomaternalpairsinahighriskpopulationreceiveroperatingcharacteristiccurveanalysis AT gonzalezllanooscar evaluationofhemoglobinperformanceintheassessmentofironstoresinfetomaternalpairsinahighriskpopulationreceiveroperatingcharacteristiccurveanalysis AT gomezalmaguerdavid evaluationofhemoglobinperformanceintheassessmentofironstoresinfetomaternalpairsinahighriskpopulationreceiveroperatingcharacteristiccurveanalysis |