HRT for the Diagnosis and Detection of Glaucoma Progression

Confocal scanning laser ophthalmoscopy through the Heidelberg Retina Tomograph (HRT) provides a rapid, safe, noncontact, and noninvasive imaging of the optic disc in three-dimensions, and provides precise detailed information about the optic disc beyond that which the clinical exam can measure. The...

Descripción completa

Detalles Bibliográficos
Autores principales: Maslin, Jessica S, Mansouri, Kaweh, Dorairaj, Syril K
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bentham Open 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4460217/
https://www.ncbi.nlm.nih.gov/pubmed/26069518
http://dx.doi.org/10.2174/1874364101509010058
_version_ 1782375347415678976
author Maslin, Jessica S
Mansouri, Kaweh
Dorairaj, Syril K
author_facet Maslin, Jessica S
Mansouri, Kaweh
Dorairaj, Syril K
author_sort Maslin, Jessica S
collection PubMed
description Confocal scanning laser ophthalmoscopy through the Heidelberg Retina Tomograph (HRT) provides a rapid, safe, noncontact, and noninvasive imaging of the optic disc in three-dimensions, and provides precise detailed information about the optic disc beyond that which the clinical exam can measure. The HRT I was developed for research purposes only and was not used clinically. The HRT II was developed to be user-friendly, more rapid, and was used as an adjunct to clinical examination in the detection and progression of glaucoma. One of the main pitfalls of the HRT II was that it was operator-dependent. The HRT III was developed to be operator-independent. Initially the Moorsfield Regression Analysis provided the analysis of the stereometric optic disc parameters. The Glaucoma Probability Score, given its ease of use, operator-independence, and rapidity of use, soon gained popularity. Numerous studies have compared these two methods of analysis, with the conclusion that the Glaucoma Probability Score provides a higher sensitivity and a lower specificity than the Moorsfield Regression Analysis, which may indicate that it has potential as a screening test for glaucoma. However, there is no consensus on the use of the Glaucoma Probability Score as a screening test for glaucoma. While HRT data may be useful as a clinical adjunct in the screening and diagnosis of glaucoma, it should ultimately only be used to support clinical examination.
format Online
Article
Text
id pubmed-4460217
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Bentham Open
record_format MEDLINE/PubMed
spelling pubmed-44602172015-06-11 HRT for the Diagnosis and Detection of Glaucoma Progression Maslin, Jessica S Mansouri, Kaweh Dorairaj, Syril K Open Ophthalmol J Article Confocal scanning laser ophthalmoscopy through the Heidelberg Retina Tomograph (HRT) provides a rapid, safe, noncontact, and noninvasive imaging of the optic disc in three-dimensions, and provides precise detailed information about the optic disc beyond that which the clinical exam can measure. The HRT I was developed for research purposes only and was not used clinically. The HRT II was developed to be user-friendly, more rapid, and was used as an adjunct to clinical examination in the detection and progression of glaucoma. One of the main pitfalls of the HRT II was that it was operator-dependent. The HRT III was developed to be operator-independent. Initially the Moorsfield Regression Analysis provided the analysis of the stereometric optic disc parameters. The Glaucoma Probability Score, given its ease of use, operator-independence, and rapidity of use, soon gained popularity. Numerous studies have compared these two methods of analysis, with the conclusion that the Glaucoma Probability Score provides a higher sensitivity and a lower specificity than the Moorsfield Regression Analysis, which may indicate that it has potential as a screening test for glaucoma. However, there is no consensus on the use of the Glaucoma Probability Score as a screening test for glaucoma. While HRT data may be useful as a clinical adjunct in the screening and diagnosis of glaucoma, it should ultimately only be used to support clinical examination. Bentham Open 2015-05-15 /pmc/articles/PMC4460217/ /pubmed/26069518 http://dx.doi.org/10.2174/1874364101509010058 Text en © Maslin et al.; Licensee Bentham Open. http://creativecommons.org/licenses/by-nc/3.0/ This is an open access article licensed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted, non-commercial use, distribution and reproduction in any medium, provided the work is properly cited.
spellingShingle Article
Maslin, Jessica S
Mansouri, Kaweh
Dorairaj, Syril K
HRT for the Diagnosis and Detection of Glaucoma Progression
title HRT for the Diagnosis and Detection of Glaucoma Progression
title_full HRT for the Diagnosis and Detection of Glaucoma Progression
title_fullStr HRT for the Diagnosis and Detection of Glaucoma Progression
title_full_unstemmed HRT for the Diagnosis and Detection of Glaucoma Progression
title_short HRT for the Diagnosis and Detection of Glaucoma Progression
title_sort hrt for the diagnosis and detection of glaucoma progression
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4460217/
https://www.ncbi.nlm.nih.gov/pubmed/26069518
http://dx.doi.org/10.2174/1874364101509010058
work_keys_str_mv AT maslinjessicas hrtforthediagnosisanddetectionofglaucomaprogression
AT mansourikaweh hrtforthediagnosisanddetectionofglaucomaprogression
AT dorairajsyrilk hrtforthediagnosisanddetectionofglaucomaprogression