Ex-vivo perfusion machines in kidney transplantation. The significance of the resistivity index

INTRODUCTION: With a growing shortage of organs for transplantation, finding ways of increasing the donor organ pool remains of utmost importance. Perfusion machines (PM) have been proven to enhance the potential for kidney transplants to function sooner, last longer, giving patients the opportunity...

Descripción completa

Detalles Bibliográficos
Autores principales: ELEC, FLORIN IOAN, LUCAN, CIPRIAN, GHERVAN, LIVIU, MUNTEANU, VALENTIN, MOGA, SILVIU, SUCIU, MIHAI, ENACHE, DAN, ELEC, ALINA, MUNTEANU, ADRIANA, BARBOS, ADRIAN, IACOB, GHEORGHITA, LUCAN, MIHAI
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Iuliu Hatieganu University of Medicine and Pharmacy 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4462411/
https://www.ncbi.nlm.nih.gov/pubmed/26527992
http://dx.doi.org/10.15386/cjm.2014.8872.871.fie1
_version_ 1782375652251402240
author ELEC, FLORIN IOAN
LUCAN, CIPRIAN
GHERVAN, LIVIU
MUNTEANU, VALENTIN
MOGA, SILVIU
SUCIU, MIHAI
ENACHE, DAN
ELEC, ALINA
MUNTEANU, ADRIANA
BARBOS, ADRIAN
IACOB, GHEORGHITA
LUCAN, MIHAI
author_facet ELEC, FLORIN IOAN
LUCAN, CIPRIAN
GHERVAN, LIVIU
MUNTEANU, VALENTIN
MOGA, SILVIU
SUCIU, MIHAI
ENACHE, DAN
ELEC, ALINA
MUNTEANU, ADRIANA
BARBOS, ADRIAN
IACOB, GHEORGHITA
LUCAN, MIHAI
author_sort ELEC, FLORIN IOAN
collection PubMed
description INTRODUCTION: With a growing shortage of organs for transplantation, finding ways of increasing the donor organ pool remains of utmost importance. Perfusion machines (PM) have been proven to enhance the potential for kidney transplants to function sooner, last longer, giving patients the opportunity for a better life quality. OBJECTIVE: The aim of this study is to evaluate the relation between the resistance index provided by the PM, the postoperative resistance index measured by Doppler ultrasound and the initial graft outcome. MATERIAL AND METHOD: Between January 2012-December 2012, clinical data obtained from 82 consecutive renal transplants from brain death donors (BDD) which underwent PM maintenance were analyzed in a transversal study. Prior transplantation we recorded the solution temperature, filtration rate and the resistance index provided by PM. After the surgical intervention, each patient had standard follow-up. Doppler ultrasound resistivity index (RI) was recorded on the first postoperative day. RESULTS: Out of 115 renal transplants, 98 (85.21%) were performed with grafts from BDD. The PM was used for 82 renal grafts. The Doppler resistance index in relation to the resistance index shows a highly statistical correlation by linear regression (R=0.813, p<0.0001). Primary graft function was recorded in 74 patients (90.24%) and it was highly statistically significant correlated with the resistance index measured by PM. Out of 8 patients with primary non-function, 6 patients recovered with normal graft function at one year. CONCLUSION: The resistivity index recorded by the life-port machine is correlated with the vascular resistivity index measured by Doppler ultrasound and thus it may predicts the primary graft outcome.
format Online
Article
Text
id pubmed-4462411
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Iuliu Hatieganu University of Medicine and Pharmacy
record_format MEDLINE/PubMed
spelling pubmed-44624112015-11-02 Ex-vivo perfusion machines in kidney transplantation. The significance of the resistivity index ELEC, FLORIN IOAN LUCAN, CIPRIAN GHERVAN, LIVIU MUNTEANU, VALENTIN MOGA, SILVIU SUCIU, MIHAI ENACHE, DAN ELEC, ALINA MUNTEANU, ADRIANA BARBOS, ADRIAN IACOB, GHEORGHITA LUCAN, MIHAI Clujul Med Original Research INTRODUCTION: With a growing shortage of organs for transplantation, finding ways of increasing the donor organ pool remains of utmost importance. Perfusion machines (PM) have been proven to enhance the potential for kidney transplants to function sooner, last longer, giving patients the opportunity for a better life quality. OBJECTIVE: The aim of this study is to evaluate the relation between the resistance index provided by the PM, the postoperative resistance index measured by Doppler ultrasound and the initial graft outcome. MATERIAL AND METHOD: Between January 2012-December 2012, clinical data obtained from 82 consecutive renal transplants from brain death donors (BDD) which underwent PM maintenance were analyzed in a transversal study. Prior transplantation we recorded the solution temperature, filtration rate and the resistance index provided by PM. After the surgical intervention, each patient had standard follow-up. Doppler ultrasound resistivity index (RI) was recorded on the first postoperative day. RESULTS: Out of 115 renal transplants, 98 (85.21%) were performed with grafts from BDD. The PM was used for 82 renal grafts. The Doppler resistance index in relation to the resistance index shows a highly statistical correlation by linear regression (R=0.813, p<0.0001). Primary graft function was recorded in 74 patients (90.24%) and it was highly statistically significant correlated with the resistance index measured by PM. Out of 8 patients with primary non-function, 6 patients recovered with normal graft function at one year. CONCLUSION: The resistivity index recorded by the life-port machine is correlated with the vascular resistivity index measured by Doppler ultrasound and thus it may predicts the primary graft outcome. Iuliu Hatieganu University of Medicine and Pharmacy 2014 2014-01-30 /pmc/articles/PMC4462411/ /pubmed/26527992 http://dx.doi.org/10.15386/cjm.2014.8872.871.fie1 Text en http://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
spellingShingle Original Research
ELEC, FLORIN IOAN
LUCAN, CIPRIAN
GHERVAN, LIVIU
MUNTEANU, VALENTIN
MOGA, SILVIU
SUCIU, MIHAI
ENACHE, DAN
ELEC, ALINA
MUNTEANU, ADRIANA
BARBOS, ADRIAN
IACOB, GHEORGHITA
LUCAN, MIHAI
Ex-vivo perfusion machines in kidney transplantation. The significance of the resistivity index
title Ex-vivo perfusion machines in kidney transplantation. The significance of the resistivity index
title_full Ex-vivo perfusion machines in kidney transplantation. The significance of the resistivity index
title_fullStr Ex-vivo perfusion machines in kidney transplantation. The significance of the resistivity index
title_full_unstemmed Ex-vivo perfusion machines in kidney transplantation. The significance of the resistivity index
title_short Ex-vivo perfusion machines in kidney transplantation. The significance of the resistivity index
title_sort ex-vivo perfusion machines in kidney transplantation. the significance of the resistivity index
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4462411/
https://www.ncbi.nlm.nih.gov/pubmed/26527992
http://dx.doi.org/10.15386/cjm.2014.8872.871.fie1
work_keys_str_mv AT elecflorinioan exvivoperfusionmachinesinkidneytransplantationthesignificanceoftheresistivityindex
AT lucanciprian exvivoperfusionmachinesinkidneytransplantationthesignificanceoftheresistivityindex
AT ghervanliviu exvivoperfusionmachinesinkidneytransplantationthesignificanceoftheresistivityindex
AT munteanuvalentin exvivoperfusionmachinesinkidneytransplantationthesignificanceoftheresistivityindex
AT mogasilviu exvivoperfusionmachinesinkidneytransplantationthesignificanceoftheresistivityindex
AT suciumihai exvivoperfusionmachinesinkidneytransplantationthesignificanceoftheresistivityindex
AT enachedan exvivoperfusionmachinesinkidneytransplantationthesignificanceoftheresistivityindex
AT elecalina exvivoperfusionmachinesinkidneytransplantationthesignificanceoftheresistivityindex
AT munteanuadriana exvivoperfusionmachinesinkidneytransplantationthesignificanceoftheresistivityindex
AT barbosadrian exvivoperfusionmachinesinkidneytransplantationthesignificanceoftheresistivityindex
AT iacobgheorghita exvivoperfusionmachinesinkidneytransplantationthesignificanceoftheresistivityindex
AT lucanmihai exvivoperfusionmachinesinkidneytransplantationthesignificanceoftheresistivityindex