Cargando…
Ex-vivo perfusion machines in kidney transplantation. The significance of the resistivity index
INTRODUCTION: With a growing shortage of organs for transplantation, finding ways of increasing the donor organ pool remains of utmost importance. Perfusion machines (PM) have been proven to enhance the potential for kidney transplants to function sooner, last longer, giving patients the opportunity...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Iuliu Hatieganu University of Medicine and Pharmacy
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4462411/ https://www.ncbi.nlm.nih.gov/pubmed/26527992 http://dx.doi.org/10.15386/cjm.2014.8872.871.fie1 |
_version_ | 1782375652251402240 |
---|---|
author | ELEC, FLORIN IOAN LUCAN, CIPRIAN GHERVAN, LIVIU MUNTEANU, VALENTIN MOGA, SILVIU SUCIU, MIHAI ENACHE, DAN ELEC, ALINA MUNTEANU, ADRIANA BARBOS, ADRIAN IACOB, GHEORGHITA LUCAN, MIHAI |
author_facet | ELEC, FLORIN IOAN LUCAN, CIPRIAN GHERVAN, LIVIU MUNTEANU, VALENTIN MOGA, SILVIU SUCIU, MIHAI ENACHE, DAN ELEC, ALINA MUNTEANU, ADRIANA BARBOS, ADRIAN IACOB, GHEORGHITA LUCAN, MIHAI |
author_sort | ELEC, FLORIN IOAN |
collection | PubMed |
description | INTRODUCTION: With a growing shortage of organs for transplantation, finding ways of increasing the donor organ pool remains of utmost importance. Perfusion machines (PM) have been proven to enhance the potential for kidney transplants to function sooner, last longer, giving patients the opportunity for a better life quality. OBJECTIVE: The aim of this study is to evaluate the relation between the resistance index provided by the PM, the postoperative resistance index measured by Doppler ultrasound and the initial graft outcome. MATERIAL AND METHOD: Between January 2012-December 2012, clinical data obtained from 82 consecutive renal transplants from brain death donors (BDD) which underwent PM maintenance were analyzed in a transversal study. Prior transplantation we recorded the solution temperature, filtration rate and the resistance index provided by PM. After the surgical intervention, each patient had standard follow-up. Doppler ultrasound resistivity index (RI) was recorded on the first postoperative day. RESULTS: Out of 115 renal transplants, 98 (85.21%) were performed with grafts from BDD. The PM was used for 82 renal grafts. The Doppler resistance index in relation to the resistance index shows a highly statistical correlation by linear regression (R=0.813, p<0.0001). Primary graft function was recorded in 74 patients (90.24%) and it was highly statistically significant correlated with the resistance index measured by PM. Out of 8 patients with primary non-function, 6 patients recovered with normal graft function at one year. CONCLUSION: The resistivity index recorded by the life-port machine is correlated with the vascular resistivity index measured by Doppler ultrasound and thus it may predicts the primary graft outcome. |
format | Online Article Text |
id | pubmed-4462411 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Iuliu Hatieganu University of Medicine and Pharmacy |
record_format | MEDLINE/PubMed |
spelling | pubmed-44624112015-11-02 Ex-vivo perfusion machines in kidney transplantation. The significance of the resistivity index ELEC, FLORIN IOAN LUCAN, CIPRIAN GHERVAN, LIVIU MUNTEANU, VALENTIN MOGA, SILVIU SUCIU, MIHAI ENACHE, DAN ELEC, ALINA MUNTEANU, ADRIANA BARBOS, ADRIAN IACOB, GHEORGHITA LUCAN, MIHAI Clujul Med Original Research INTRODUCTION: With a growing shortage of organs for transplantation, finding ways of increasing the donor organ pool remains of utmost importance. Perfusion machines (PM) have been proven to enhance the potential for kidney transplants to function sooner, last longer, giving patients the opportunity for a better life quality. OBJECTIVE: The aim of this study is to evaluate the relation between the resistance index provided by the PM, the postoperative resistance index measured by Doppler ultrasound and the initial graft outcome. MATERIAL AND METHOD: Between January 2012-December 2012, clinical data obtained from 82 consecutive renal transplants from brain death donors (BDD) which underwent PM maintenance were analyzed in a transversal study. Prior transplantation we recorded the solution temperature, filtration rate and the resistance index provided by PM. After the surgical intervention, each patient had standard follow-up. Doppler ultrasound resistivity index (RI) was recorded on the first postoperative day. RESULTS: Out of 115 renal transplants, 98 (85.21%) were performed with grafts from BDD. The PM was used for 82 renal grafts. The Doppler resistance index in relation to the resistance index shows a highly statistical correlation by linear regression (R=0.813, p<0.0001). Primary graft function was recorded in 74 patients (90.24%) and it was highly statistically significant correlated with the resistance index measured by PM. Out of 8 patients with primary non-function, 6 patients recovered with normal graft function at one year. CONCLUSION: The resistivity index recorded by the life-port machine is correlated with the vascular resistivity index measured by Doppler ultrasound and thus it may predicts the primary graft outcome. Iuliu Hatieganu University of Medicine and Pharmacy 2014 2014-01-30 /pmc/articles/PMC4462411/ /pubmed/26527992 http://dx.doi.org/10.15386/cjm.2014.8872.871.fie1 Text en http://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License |
spellingShingle | Original Research ELEC, FLORIN IOAN LUCAN, CIPRIAN GHERVAN, LIVIU MUNTEANU, VALENTIN MOGA, SILVIU SUCIU, MIHAI ENACHE, DAN ELEC, ALINA MUNTEANU, ADRIANA BARBOS, ADRIAN IACOB, GHEORGHITA LUCAN, MIHAI Ex-vivo perfusion machines in kidney transplantation. The significance of the resistivity index |
title | Ex-vivo perfusion machines in kidney transplantation. The significance of the resistivity index |
title_full | Ex-vivo perfusion machines in kidney transplantation. The significance of the resistivity index |
title_fullStr | Ex-vivo perfusion machines in kidney transplantation. The significance of the resistivity index |
title_full_unstemmed | Ex-vivo perfusion machines in kidney transplantation. The significance of the resistivity index |
title_short | Ex-vivo perfusion machines in kidney transplantation. The significance of the resistivity index |
title_sort | ex-vivo perfusion machines in kidney transplantation. the significance of the resistivity index |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4462411/ https://www.ncbi.nlm.nih.gov/pubmed/26527992 http://dx.doi.org/10.15386/cjm.2014.8872.871.fie1 |
work_keys_str_mv | AT elecflorinioan exvivoperfusionmachinesinkidneytransplantationthesignificanceoftheresistivityindex AT lucanciprian exvivoperfusionmachinesinkidneytransplantationthesignificanceoftheresistivityindex AT ghervanliviu exvivoperfusionmachinesinkidneytransplantationthesignificanceoftheresistivityindex AT munteanuvalentin exvivoperfusionmachinesinkidneytransplantationthesignificanceoftheresistivityindex AT mogasilviu exvivoperfusionmachinesinkidneytransplantationthesignificanceoftheresistivityindex AT suciumihai exvivoperfusionmachinesinkidneytransplantationthesignificanceoftheresistivityindex AT enachedan exvivoperfusionmachinesinkidneytransplantationthesignificanceoftheresistivityindex AT elecalina exvivoperfusionmachinesinkidneytransplantationthesignificanceoftheresistivityindex AT munteanuadriana exvivoperfusionmachinesinkidneytransplantationthesignificanceoftheresistivityindex AT barbosadrian exvivoperfusionmachinesinkidneytransplantationthesignificanceoftheresistivityindex AT iacobgheorghita exvivoperfusionmachinesinkidneytransplantationthesignificanceoftheresistivityindex AT lucanmihai exvivoperfusionmachinesinkidneytransplantationthesignificanceoftheresistivityindex |