Study of novel coating strategy for coronary stents: simutaneous coating of VEGF and anti- CD34 antibody
INTRODUCTION: Intravascular coronary stenting has been used in the treatment of coronary artery disease (CAD), with a major limitation of in-stent restenosis (ISR). The 316 stainless steel has been widely used for coronary stents. In this study, we developed a novel coating method to reduce ISR by s...
Autores principales: | , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Sociedade Brasileira de Cirurgia Cardiovascular
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4462960/ https://www.ncbi.nlm.nih.gov/pubmed/26107446 http://dx.doi.org/10.5935/1678-9741.20150016 |
Sumario: | INTRODUCTION: Intravascular coronary stenting has been used in the treatment of coronary artery disease (CAD), with a major limitation of in-stent restenosis (ISR). The 316 stainless steel has been widely used for coronary stents. In this study, we developed a novel coating method to reduce ISR by simultaneously coating vascular endothelial growth factor (VEGF) and anti-CD34 antibody on 316L stainless steel. METHODS: Round 316L stainless steel sheets in the D-H group were polymerized with compounds generated from condensation reaction of dopamine and heparin using N-(3-dimethylaminopropyl)-N'-ethylcarbodiimide (EDC) and N-hydroxysuccinimide (NHS). Sixteen sheets from the D-H group were further immersed into 1ug/ml VEGF(165) and 3mg/ml heparin sodium one after another for 10 times, and named as the D-(H-V)(10) group. Eight sheets from the D-(H-V)(10) group were coated with anti-CD34 antibody and termed as the D-(H-V)(10)-A group. Immunofluorescence assay and ELISA were used to evaluate whether the 316L stainless steel disks were successfully coated with VEGF and anti-CD34 antibody. RESULTS: The results of immunofluorescence assay and ELISA showed that VEGF could be detected in the D-(H-V)(10) and D-(H-V)(10)-A group, suggesting the steel sheets were successfully covered with VEGF. Anti-CD34 antibody could only be observed in the D-(H-V)(10)-A group, which was the only group coated with CD34 antibody. Both results suggested that the 316L stainless steel sheets were successfully coated with VEGF and anti-CD34 antibody. CONCLUSION: Our study developed a method to simultaneously coat VEGF and anti-CD34 antibody to stainless metal steel. This research serves as a fundamental role for a novel coating strategy. Descriptors: Coronary Artery Disease. Drug-Eluting Stents. Coronary Restenosis. Vascular Endothelial Growth Factor. Antigens, CD34. |
---|