Cargando…
Evaluation of the dosimetric impact of applying flattening filter-free beams in intensity-modulated radiotherapy for early-stage upper thoracic carcinoma of oesophagus
INTRODUCTION: Flattening filter-free (FFF) radiation beams have recently become clinically available on modern linear accelerators in radiation therapy. This study aimed to evaluate the dosimetric impact of using FFF beams in intensity-modulated radiotherapy (IMRT) for early-stage upper thoracic oes...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BlackWell Publishing Ltd
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4462982/ https://www.ncbi.nlm.nih.gov/pubmed/26229675 http://dx.doi.org/10.1002/jmrs.93 |
_version_ | 1782375747955982336 |
---|---|
author | Zhang, Wuzhe Lin, Zhixiong Yang, Zhining Fang, Weisheng Lai, Peibo Lu, Jiayang Wu, Vincent WC |
author_facet | Zhang, Wuzhe Lin, Zhixiong Yang, Zhining Fang, Weisheng Lai, Peibo Lu, Jiayang Wu, Vincent WC |
author_sort | Zhang, Wuzhe |
collection | PubMed |
description | INTRODUCTION: Flattening filter-free (FFF) radiation beams have recently become clinically available on modern linear accelerators in radiation therapy. This study aimed to evaluate the dosimetric impact of using FFF beams in intensity-modulated radiotherapy (IMRT) for early-stage upper thoracic oesophageal cancer. METHODS: Eleven patients with primary stage upper thoracic oesophageal cancer were recruited. For each patient, two IMRT plans were computed using conventional beams (Con-P) and FFF beams (FFF-P), respectively. Both plans employed a five-beam arrangement and were prescribed with 64 Gy to (planning target volume) PTV1 and 54 Gy to PTV2 in 32 fractions using 6 MV photons. The dose parameters of the target volumes and organs at risks (OARs), and treatment parameters including the monitor units (MU) and treatment time (TT) for Con-P and FFF-P were recorded and compared. RESULTS: The mean D(5) of PTV1 and PTV2 were higher in FFF-P than Con-P by 0.4 Gy and 0.3 Gy, respectively. For the OARs, all the dose parameters did not show significant difference between the two plans except the mean V(5) and V(10) of the lung in which the FFF-P was lower (46.7% vs. 47.3% and 39.1% vs. 39.6%, respectively). FFF-P required 54% more MU but 18.4% less irradiation time when compared to Con-P. CONCLUSION: The target volume and OARs dose distributions between the two plans were comparable. However, FFF-P was more effective in sparing the lung from low dose and reduced the mean TT compared with Con-P. Long-term clinical studies are suggested to evaluate the radiobiological effects of FFF beams. |
format | Online Article Text |
id | pubmed-4462982 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | BlackWell Publishing Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-44629822015-06-16 Evaluation of the dosimetric impact of applying flattening filter-free beams in intensity-modulated radiotherapy for early-stage upper thoracic carcinoma of oesophagus Zhang, Wuzhe Lin, Zhixiong Yang, Zhining Fang, Weisheng Lai, Peibo Lu, Jiayang Wu, Vincent WC J Med Radiat Sci Original Articles INTRODUCTION: Flattening filter-free (FFF) radiation beams have recently become clinically available on modern linear accelerators in radiation therapy. This study aimed to evaluate the dosimetric impact of using FFF beams in intensity-modulated radiotherapy (IMRT) for early-stage upper thoracic oesophageal cancer. METHODS: Eleven patients with primary stage upper thoracic oesophageal cancer were recruited. For each patient, two IMRT plans were computed using conventional beams (Con-P) and FFF beams (FFF-P), respectively. Both plans employed a five-beam arrangement and were prescribed with 64 Gy to (planning target volume) PTV1 and 54 Gy to PTV2 in 32 fractions using 6 MV photons. The dose parameters of the target volumes and organs at risks (OARs), and treatment parameters including the monitor units (MU) and treatment time (TT) for Con-P and FFF-P were recorded and compared. RESULTS: The mean D(5) of PTV1 and PTV2 were higher in FFF-P than Con-P by 0.4 Gy and 0.3 Gy, respectively. For the OARs, all the dose parameters did not show significant difference between the two plans except the mean V(5) and V(10) of the lung in which the FFF-P was lower (46.7% vs. 47.3% and 39.1% vs. 39.6%, respectively). FFF-P required 54% more MU but 18.4% less irradiation time when compared to Con-P. CONCLUSION: The target volume and OARs dose distributions between the two plans were comparable. However, FFF-P was more effective in sparing the lung from low dose and reduced the mean TT compared with Con-P. Long-term clinical studies are suggested to evaluate the radiobiological effects of FFF beams. BlackWell Publishing Ltd 2015-06 2015-01-14 /pmc/articles/PMC4462982/ /pubmed/26229675 http://dx.doi.org/10.1002/jmrs.93 Text en © 2015 The Authors. Journal of Medical Radiation Sciences published by Wiley Publishing Asia Pty Ltd on behalf of Australian Institute of Radiography and New Zealand Institute of Medical Radiation Technology. http://creativecommons.org/licenses/by-nc/4.0/ This is an open access article under the terms of the Creative Commons Attribution-NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes. |
spellingShingle | Original Articles Zhang, Wuzhe Lin, Zhixiong Yang, Zhining Fang, Weisheng Lai, Peibo Lu, Jiayang Wu, Vincent WC Evaluation of the dosimetric impact of applying flattening filter-free beams in intensity-modulated radiotherapy for early-stage upper thoracic carcinoma of oesophagus |
title | Evaluation of the dosimetric impact of applying flattening filter-free beams in intensity-modulated radiotherapy for early-stage upper thoracic carcinoma of oesophagus |
title_full | Evaluation of the dosimetric impact of applying flattening filter-free beams in intensity-modulated radiotherapy for early-stage upper thoracic carcinoma of oesophagus |
title_fullStr | Evaluation of the dosimetric impact of applying flattening filter-free beams in intensity-modulated radiotherapy for early-stage upper thoracic carcinoma of oesophagus |
title_full_unstemmed | Evaluation of the dosimetric impact of applying flattening filter-free beams in intensity-modulated radiotherapy for early-stage upper thoracic carcinoma of oesophagus |
title_short | Evaluation of the dosimetric impact of applying flattening filter-free beams in intensity-modulated radiotherapy for early-stage upper thoracic carcinoma of oesophagus |
title_sort | evaluation of the dosimetric impact of applying flattening filter-free beams in intensity-modulated radiotherapy for early-stage upper thoracic carcinoma of oesophagus |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4462982/ https://www.ncbi.nlm.nih.gov/pubmed/26229675 http://dx.doi.org/10.1002/jmrs.93 |
work_keys_str_mv | AT zhangwuzhe evaluationofthedosimetricimpactofapplyingflatteningfilterfreebeamsinintensitymodulatedradiotherapyforearlystageupperthoraciccarcinomaofoesophagus AT linzhixiong evaluationofthedosimetricimpactofapplyingflatteningfilterfreebeamsinintensitymodulatedradiotherapyforearlystageupperthoraciccarcinomaofoesophagus AT yangzhining evaluationofthedosimetricimpactofapplyingflatteningfilterfreebeamsinintensitymodulatedradiotherapyforearlystageupperthoraciccarcinomaofoesophagus AT fangweisheng evaluationofthedosimetricimpactofapplyingflatteningfilterfreebeamsinintensitymodulatedradiotherapyforearlystageupperthoraciccarcinomaofoesophagus AT laipeibo evaluationofthedosimetricimpactofapplyingflatteningfilterfreebeamsinintensitymodulatedradiotherapyforearlystageupperthoraciccarcinomaofoesophagus AT lujiayang evaluationofthedosimetricimpactofapplyingflatteningfilterfreebeamsinintensitymodulatedradiotherapyforearlystageupperthoraciccarcinomaofoesophagus AT wuvincentwc evaluationofthedosimetricimpactofapplyingflatteningfilterfreebeamsinintensitymodulatedradiotherapyforearlystageupperthoraciccarcinomaofoesophagus |