Cargando…

A new electrode placement method for obtaining 12-lead ECGs

OBJECTIVE: Worldwide, more than 50 million ECGs are carried out annually. Studies show that the standard wrist–ankle placement method may produce poor quality ECGs. Factors including limb movement, tremor, anxiety, cold extremities cause artefacts (distortions of the baseline and ECG waveforms). A p...

Descripción completa

Detalles Bibliográficos
Autor principal: Khan, Gabriel M
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4463488/
https://www.ncbi.nlm.nih.gov/pubmed/26082845
http://dx.doi.org/10.1136/openhrt-2014-000226
_version_ 1782375773078814720
author Khan, Gabriel M
author_facet Khan, Gabriel M
author_sort Khan, Gabriel M
collection PubMed
description OBJECTIVE: Worldwide, more than 50 million ECGs are carried out annually. Studies show that the standard wrist–ankle placement method may produce poor quality ECGs. Factors including limb movement, tremor, anxiety, cold extremities cause artefacts (distortions of the baseline and ECG waveforms). A problem exists. Physicians face a challenge interpreting poor quality ECGs. Diagnostic delays occur. Patients are subjected to recalls; compassion initiated this study. Torso (modified) leads are favoured as they provide rapid acquisition of better quality ECGs, but cause erroneous electrocardiography. Investigators have not attempted to correct these errors. This study analyses the errors and aims to rectify them. METHODS: Our pilot and other studies indicated that torso electrodes placed close to the heart cause an increase in R wave amplitude >3 mm in inferior leads that results in disappearance of inferior infarcts; a decrease >3 mm in 1 and aVL may cause false lateral infarcts. We hypothesised that finding electrode placements that do not cause alterations in R wave amplitude should correct these problems. Several electrode placements were assessed to obtain ECGs identical with the standard, but with better quality. A total of 1112 patients received standard and new electrode placement recordings. ECG parameters were assessed. A blinded interpreter assisted. RESULTS: Electrodes positioned on the mid-arm and lower abdomen revealed ECGs identical with the standard without artefacts or loss of inferior or appearance of lateral infarcts. CONCLUSIONS: This study proved that the new method is faultless and provides better quality ECGs, no recalls and without risk for misinterpretations. Not having to remove leg garments is convenient and allows more rapid acquisition of ECGs. The forearms are freed for, intravenous, radial access, and ECGs needed during procedures. The findings have implications worldwide for patients, clinicians and technicians, and generate the need to study the method in emergency settings.
format Online
Article
Text
id pubmed-4463488
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-44634882015-06-16 A new electrode placement method for obtaining 12-lead ECGs Khan, Gabriel M Open Heart Health Care Delivery, Economics and Global Health Care OBJECTIVE: Worldwide, more than 50 million ECGs are carried out annually. Studies show that the standard wrist–ankle placement method may produce poor quality ECGs. Factors including limb movement, tremor, anxiety, cold extremities cause artefacts (distortions of the baseline and ECG waveforms). A problem exists. Physicians face a challenge interpreting poor quality ECGs. Diagnostic delays occur. Patients are subjected to recalls; compassion initiated this study. Torso (modified) leads are favoured as they provide rapid acquisition of better quality ECGs, but cause erroneous electrocardiography. Investigators have not attempted to correct these errors. This study analyses the errors and aims to rectify them. METHODS: Our pilot and other studies indicated that torso electrodes placed close to the heart cause an increase in R wave amplitude >3 mm in inferior leads that results in disappearance of inferior infarcts; a decrease >3 mm in 1 and aVL may cause false lateral infarcts. We hypothesised that finding electrode placements that do not cause alterations in R wave amplitude should correct these problems. Several electrode placements were assessed to obtain ECGs identical with the standard, but with better quality. A total of 1112 patients received standard and new electrode placement recordings. ECG parameters were assessed. A blinded interpreter assisted. RESULTS: Electrodes positioned on the mid-arm and lower abdomen revealed ECGs identical with the standard without artefacts or loss of inferior or appearance of lateral infarcts. CONCLUSIONS: This study proved that the new method is faultless and provides better quality ECGs, no recalls and without risk for misinterpretations. Not having to remove leg garments is convenient and allows more rapid acquisition of ECGs. The forearms are freed for, intravenous, radial access, and ECGs needed during procedures. The findings have implications worldwide for patients, clinicians and technicians, and generate the need to study the method in emergency settings. BMJ Publishing Group 2015-06-09 /pmc/articles/PMC4463488/ /pubmed/26082845 http://dx.doi.org/10.1136/openhrt-2014-000226 Text en Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions This is an Open Access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
spellingShingle Health Care Delivery, Economics and Global Health Care
Khan, Gabriel M
A new electrode placement method for obtaining 12-lead ECGs
title A new electrode placement method for obtaining 12-lead ECGs
title_full A new electrode placement method for obtaining 12-lead ECGs
title_fullStr A new electrode placement method for obtaining 12-lead ECGs
title_full_unstemmed A new electrode placement method for obtaining 12-lead ECGs
title_short A new electrode placement method for obtaining 12-lead ECGs
title_sort new electrode placement method for obtaining 12-lead ecgs
topic Health Care Delivery, Economics and Global Health Care
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4463488/
https://www.ncbi.nlm.nih.gov/pubmed/26082845
http://dx.doi.org/10.1136/openhrt-2014-000226
work_keys_str_mv AT khangabrielm anewelectrodeplacementmethodforobtaining12leadecgs
AT khangabrielm newelectrodeplacementmethodforobtaining12leadecgs