Cargando…

Application of mixsep software package: Performance verification of male-mixed DNA analysis

An experimental model of male-mixed DNA (n=297) was constructed according to the mixed DNA construction principle. This comprised the use of the Applied Biosystems (ABI) 7500 quantitative polymerase chain reaction system, with scientific validation of mixture proportion (Mx; root-mean-square error ≤...

Descripción completa

Detalles Bibliográficos
Autores principales: HU, NA, CONG, BIN, GAO, TAO, CHEN, YU, SHEN, JUNYI, LI, SHUJIN, MA, CHUNLING
Formato: Online Artículo Texto
Lenguaje:English
Publicado: D.A. Spandidos 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4464469/
https://www.ncbi.nlm.nih.gov/pubmed/25936428
http://dx.doi.org/10.3892/mmr.2015.3710
_version_ 1782375977445228544
author HU, NA
CONG, BIN
GAO, TAO
CHEN, YU
SHEN, JUNYI
LI, SHUJIN
MA, CHUNLING
author_facet HU, NA
CONG, BIN
GAO, TAO
CHEN, YU
SHEN, JUNYI
LI, SHUJIN
MA, CHUNLING
author_sort HU, NA
collection PubMed
description An experimental model of male-mixed DNA (n=297) was constructed according to the mixed DNA construction principle. This comprised the use of the Applied Biosystems (ABI) 7500 quantitative polymerase chain reaction system, with scientific validation of mixture proportion (Mx; root-mean-square error ≤0.02). Statistical analysis was performed on locus separation accuracy using mixsep, a DNA mixture separation R-package, and the analytical performance of mixsep was assessed by examining the data distribution pattern of different mixed gradients, short tandem repeat (STR) loci and mixed DNA types. The results showed that locus separation accuracy had a negative linear correlation with the mixed gradient (R(2)=−0.7121). With increasing mixed gradient imbalance, locus separation accuracy first increased and then decreased, with the highest value detected at a gradient of 1:3 (≥90%). The mixed gradient, which is the theoretical Mx, was one of the primary factors that influenced the success of mixed DNA analysis. Among the 16 STR loci detected by Identifiler(®), the separation accuracy was relatively high (>88%) for loci D5S818, D8S1179 and FGA, whereas the median separation accuracy value was lowest for the D7S820 locus. STR loci with relatively large numbers of allelic drop-out (ADO; >15) were all located in the yellow and red channels, including loci D18S51, D19S433, FGA, TPOX and vWA. These five loci featured low allele peak heights, which was consistent with the low sensitivity of the ABI 3130xl Genetic Analyzer to yellow and red fluorescence. The locus separation accuracy of the mixsep package was substantially different with and without the inclusion of ADO loci; inclusion of ADO significantly reduced the analytical performance of the mixsep package, which was consistent with the lack of an ADO functional module in this software. The present study demonstrated that the mixsep software had a number of advantages and was recommended for analysis of mixed DNA. This software was easy to operate and produced understandable results with a degree of controllability.
format Online
Article
Text
id pubmed-4464469
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher D.A. Spandidos
record_format MEDLINE/PubMed
spelling pubmed-44644692015-06-26 Application of mixsep software package: Performance verification of male-mixed DNA analysis HU, NA CONG, BIN GAO, TAO CHEN, YU SHEN, JUNYI LI, SHUJIN MA, CHUNLING Mol Med Rep Articles An experimental model of male-mixed DNA (n=297) was constructed according to the mixed DNA construction principle. This comprised the use of the Applied Biosystems (ABI) 7500 quantitative polymerase chain reaction system, with scientific validation of mixture proportion (Mx; root-mean-square error ≤0.02). Statistical analysis was performed on locus separation accuracy using mixsep, a DNA mixture separation R-package, and the analytical performance of mixsep was assessed by examining the data distribution pattern of different mixed gradients, short tandem repeat (STR) loci and mixed DNA types. The results showed that locus separation accuracy had a negative linear correlation with the mixed gradient (R(2)=−0.7121). With increasing mixed gradient imbalance, locus separation accuracy first increased and then decreased, with the highest value detected at a gradient of 1:3 (≥90%). The mixed gradient, which is the theoretical Mx, was one of the primary factors that influenced the success of mixed DNA analysis. Among the 16 STR loci detected by Identifiler(®), the separation accuracy was relatively high (>88%) for loci D5S818, D8S1179 and FGA, whereas the median separation accuracy value was lowest for the D7S820 locus. STR loci with relatively large numbers of allelic drop-out (ADO; >15) were all located in the yellow and red channels, including loci D18S51, D19S433, FGA, TPOX and vWA. These five loci featured low allele peak heights, which was consistent with the low sensitivity of the ABI 3130xl Genetic Analyzer to yellow and red fluorescence. The locus separation accuracy of the mixsep package was substantially different with and without the inclusion of ADO loci; inclusion of ADO significantly reduced the analytical performance of the mixsep package, which was consistent with the lack of an ADO functional module in this software. The present study demonstrated that the mixsep software had a number of advantages and was recommended for analysis of mixed DNA. This software was easy to operate and produced understandable results with a degree of controllability. D.A. Spandidos 2015-08 2015-04-30 /pmc/articles/PMC4464469/ /pubmed/25936428 http://dx.doi.org/10.3892/mmr.2015.3710 Text en Copyright © 2015, Spandidos Publications http://creativecommons.org/licenses/by/3.0 This is an open-access article licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported License. The article may be redistributed, reproduced, and reused for non-commercial purposes, provided the original source is properly cited.
spellingShingle Articles
HU, NA
CONG, BIN
GAO, TAO
CHEN, YU
SHEN, JUNYI
LI, SHUJIN
MA, CHUNLING
Application of mixsep software package: Performance verification of male-mixed DNA analysis
title Application of mixsep software package: Performance verification of male-mixed DNA analysis
title_full Application of mixsep software package: Performance verification of male-mixed DNA analysis
title_fullStr Application of mixsep software package: Performance verification of male-mixed DNA analysis
title_full_unstemmed Application of mixsep software package: Performance verification of male-mixed DNA analysis
title_short Application of mixsep software package: Performance verification of male-mixed DNA analysis
title_sort application of mixsep software package: performance verification of male-mixed dna analysis
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4464469/
https://www.ncbi.nlm.nih.gov/pubmed/25936428
http://dx.doi.org/10.3892/mmr.2015.3710
work_keys_str_mv AT huna applicationofmixsepsoftwarepackageperformanceverificationofmalemixeddnaanalysis
AT congbin applicationofmixsepsoftwarepackageperformanceverificationofmalemixeddnaanalysis
AT gaotao applicationofmixsepsoftwarepackageperformanceverificationofmalemixeddnaanalysis
AT chenyu applicationofmixsepsoftwarepackageperformanceverificationofmalemixeddnaanalysis
AT shenjunyi applicationofmixsepsoftwarepackageperformanceverificationofmalemixeddnaanalysis
AT lishujin applicationofmixsepsoftwarepackageperformanceverificationofmalemixeddnaanalysis
AT machunling applicationofmixsepsoftwarepackageperformanceverificationofmalemixeddnaanalysis