Cargando…

Pulmonary Nodule Detection in Patients with a Primary Malignancy Using Hybrid PET/MRI: Is There Value in Adding Contrast-Enhanced MR Imaging?

PURPOSE: To investigate the added value of post-contrast VIBE (volumetric-interpolated breath-hold examination) to PET/MR imaging for pulmonary nodule detection in patients with primary malignancies. MATERIALS AND METHODS: This retrospective institutional review board–approved study, with waiver of...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Kyung Hee, Park, Chang Min, Lee, Sang Min, Lee, Jeong Min, Cho, Jeong Yeon, Paeng, Jin Chul, Ahn, Su Yeon, Goo, Jin Mo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4465933/
https://www.ncbi.nlm.nih.gov/pubmed/26065695
http://dx.doi.org/10.1371/journal.pone.0129660
_version_ 1782376148957659136
author Lee, Kyung Hee
Park, Chang Min
Lee, Sang Min
Lee, Jeong Min
Cho, Jeong Yeon
Paeng, Jin Chul
Ahn, Su Yeon
Goo, Jin Mo
author_facet Lee, Kyung Hee
Park, Chang Min
Lee, Sang Min
Lee, Jeong Min
Cho, Jeong Yeon
Paeng, Jin Chul
Ahn, Su Yeon
Goo, Jin Mo
author_sort Lee, Kyung Hee
collection PubMed
description PURPOSE: To investigate the added value of post-contrast VIBE (volumetric-interpolated breath-hold examination) to PET/MR imaging for pulmonary nodule detection in patients with primary malignancies. MATERIALS AND METHODS: This retrospective institutional review board–approved study, with waiver of informed consent, included 51 consecutive patients who underwent (18)F-fluorodeoxyglucose (FDG) PET/MR followed by PET/CT for cancer staging. In all patients, the thorax was examined with pre-and post-contrast VIBE MR with simultaneous PET acquisition. Two readers blinded to the patients’ data independently recorded their level of suspicion for pulmonary nodules based on PET, pre-contrast VIBE, and fused PET/MR images (first session), and reassessed them 4-weeks later after addition of post-contrast VIBE (second session). Jackknife alternative free-response receiver-operating-characteristic (JAFROC) analysis was performed, with PET/CT as the reference standard. RESULTS: A total of 151 pulmonary nodules (44 FDG-avid, 107 non-FDG-avid nodules) were detected on PET/CT, including 62 nodules≥5mm in diameter and 89 nodules<5mm. In the first session, the average nodule detection rate was 53.3% for all nodules, 97.7% for FDG-avid, 35.0% for non-FDG-avid nodules, 87.9% for nodules≥5mm and 29.2% for nodules<5mm. In the second session, the average detection rate was 53.3% for all nodules, 97.7% for FDG-avid, 35.0% for non-FDG-avid nodules, 85.5% for nodules≥5mm and 30.9% for nodules<5mm. The average JAFROC figure-of-merit was 0.837 in the first session and 0.848 in the second session. There were no significant differences in detection performance between sessions (P=0.48). CONCLUSION: The addition of post-contrast VIBE to hybrid PET/MR imaging provided no additional value in the detection of pulmonary nodules.
format Online
Article
Text
id pubmed-4465933
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-44659332015-06-25 Pulmonary Nodule Detection in Patients with a Primary Malignancy Using Hybrid PET/MRI: Is There Value in Adding Contrast-Enhanced MR Imaging? Lee, Kyung Hee Park, Chang Min Lee, Sang Min Lee, Jeong Min Cho, Jeong Yeon Paeng, Jin Chul Ahn, Su Yeon Goo, Jin Mo PLoS One Research Article PURPOSE: To investigate the added value of post-contrast VIBE (volumetric-interpolated breath-hold examination) to PET/MR imaging for pulmonary nodule detection in patients with primary malignancies. MATERIALS AND METHODS: This retrospective institutional review board–approved study, with waiver of informed consent, included 51 consecutive patients who underwent (18)F-fluorodeoxyglucose (FDG) PET/MR followed by PET/CT for cancer staging. In all patients, the thorax was examined with pre-and post-contrast VIBE MR with simultaneous PET acquisition. Two readers blinded to the patients’ data independently recorded their level of suspicion for pulmonary nodules based on PET, pre-contrast VIBE, and fused PET/MR images (first session), and reassessed them 4-weeks later after addition of post-contrast VIBE (second session). Jackknife alternative free-response receiver-operating-characteristic (JAFROC) analysis was performed, with PET/CT as the reference standard. RESULTS: A total of 151 pulmonary nodules (44 FDG-avid, 107 non-FDG-avid nodules) were detected on PET/CT, including 62 nodules≥5mm in diameter and 89 nodules<5mm. In the first session, the average nodule detection rate was 53.3% for all nodules, 97.7% for FDG-avid, 35.0% for non-FDG-avid nodules, 87.9% for nodules≥5mm and 29.2% for nodules<5mm. In the second session, the average detection rate was 53.3% for all nodules, 97.7% for FDG-avid, 35.0% for non-FDG-avid nodules, 85.5% for nodules≥5mm and 30.9% for nodules<5mm. The average JAFROC figure-of-merit was 0.837 in the first session and 0.848 in the second session. There were no significant differences in detection performance between sessions (P=0.48). CONCLUSION: The addition of post-contrast VIBE to hybrid PET/MR imaging provided no additional value in the detection of pulmonary nodules. Public Library of Science 2015-06-11 /pmc/articles/PMC4465933/ /pubmed/26065695 http://dx.doi.org/10.1371/journal.pone.0129660 Text en © 2015 Lee et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Lee, Kyung Hee
Park, Chang Min
Lee, Sang Min
Lee, Jeong Min
Cho, Jeong Yeon
Paeng, Jin Chul
Ahn, Su Yeon
Goo, Jin Mo
Pulmonary Nodule Detection in Patients with a Primary Malignancy Using Hybrid PET/MRI: Is There Value in Adding Contrast-Enhanced MR Imaging?
title Pulmonary Nodule Detection in Patients with a Primary Malignancy Using Hybrid PET/MRI: Is There Value in Adding Contrast-Enhanced MR Imaging?
title_full Pulmonary Nodule Detection in Patients with a Primary Malignancy Using Hybrid PET/MRI: Is There Value in Adding Contrast-Enhanced MR Imaging?
title_fullStr Pulmonary Nodule Detection in Patients with a Primary Malignancy Using Hybrid PET/MRI: Is There Value in Adding Contrast-Enhanced MR Imaging?
title_full_unstemmed Pulmonary Nodule Detection in Patients with a Primary Malignancy Using Hybrid PET/MRI: Is There Value in Adding Contrast-Enhanced MR Imaging?
title_short Pulmonary Nodule Detection in Patients with a Primary Malignancy Using Hybrid PET/MRI: Is There Value in Adding Contrast-Enhanced MR Imaging?
title_sort pulmonary nodule detection in patients with a primary malignancy using hybrid pet/mri: is there value in adding contrast-enhanced mr imaging?
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4465933/
https://www.ncbi.nlm.nih.gov/pubmed/26065695
http://dx.doi.org/10.1371/journal.pone.0129660
work_keys_str_mv AT leekyunghee pulmonarynoduledetectioninpatientswithaprimarymalignancyusinghybridpetmriistherevalueinaddingcontrastenhancedmrimaging
AT parkchangmin pulmonarynoduledetectioninpatientswithaprimarymalignancyusinghybridpetmriistherevalueinaddingcontrastenhancedmrimaging
AT leesangmin pulmonarynoduledetectioninpatientswithaprimarymalignancyusinghybridpetmriistherevalueinaddingcontrastenhancedmrimaging
AT leejeongmin pulmonarynoduledetectioninpatientswithaprimarymalignancyusinghybridpetmriistherevalueinaddingcontrastenhancedmrimaging
AT chojeongyeon pulmonarynoduledetectioninpatientswithaprimarymalignancyusinghybridpetmriistherevalueinaddingcontrastenhancedmrimaging
AT paengjinchul pulmonarynoduledetectioninpatientswithaprimarymalignancyusinghybridpetmriistherevalueinaddingcontrastenhancedmrimaging
AT ahnsuyeon pulmonarynoduledetectioninpatientswithaprimarymalignancyusinghybridpetmriistherevalueinaddingcontrastenhancedmrimaging
AT goojinmo pulmonarynoduledetectioninpatientswithaprimarymalignancyusinghybridpetmriistherevalueinaddingcontrastenhancedmrimaging