Cargando…

Intensity-Corrected Dual-Echo Echo-Planar Imaging (DE-EPI) for Improved Pediatric Brain Diffusion Imaging

Here we investigate the utility of a dual-echo Echo-Planar Imaging (DE-EPI) Diffusion Weighted Imaging (DWI) approach to improve lesion conspicuity in pediatric imaging. This method delivers two ‘echo images’ for one diffusion-preparation period. We also demonstrate how the echoes can be utilized to...

Descripción completa

Detalles Bibliográficos
Autores principales: Yeom, Kristen W., Straka, Matus, Iv, Michael, Moseley, Michael E., Barnes, Patrick D., Skare, Stefan, Holdsworth, Samantha J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4466387/
https://www.ncbi.nlm.nih.gov/pubmed/26069959
http://dx.doi.org/10.1371/journal.pone.0129325
_version_ 1782376204839419904
author Yeom, Kristen W.
Straka, Matus
Iv, Michael
Moseley, Michael E.
Barnes, Patrick D.
Skare, Stefan
Holdsworth, Samantha J.
author_facet Yeom, Kristen W.
Straka, Matus
Iv, Michael
Moseley, Michael E.
Barnes, Patrick D.
Skare, Stefan
Holdsworth, Samantha J.
author_sort Yeom, Kristen W.
collection PubMed
description Here we investigate the utility of a dual-echo Echo-Planar Imaging (DE-EPI) Diffusion Weighted Imaging (DWI) approach to improve lesion conspicuity in pediatric imaging. This method delivers two ‘echo images’ for one diffusion-preparation period. We also demonstrate how the echoes can be utilized to remove transmit/receive coil-induced and static magnetic field intensity modulations on both echo images, which often mimic pathology and thereby pose diagnostic challenges. DE-EPI DWI data were acquired in 18 pediatric patients with abnormal diffusion lesions, and 46 pediatric patient controls at 3T. Echo1 [TE = 45ms] and Echo2 [TE = 86ms] were corrected for signal intensity variation across the images by exploiting the images equivalent coil-sensitivity and susceptibility-induced modulations. Two neuroradiologists independently reviewed Echo1 and Echo2 and their intensity-corrected variants (cEcho1 and cEcho2) on a 7-point Likert scale, with grading on lesion conspicuity diagnostic confidence. The apparent diffusion coefficient (ADC) map from Echo1 was used to validate presence of true pathology. Echo2 was unanimously favored over Echo1 for its sensitivity for detecting acute brain injury, with a mean respective lesion conspicuity of 5.7/4.4 (p < 0.005) and diagnostic confidence of 5.1/4.3 (p = 0.025). cEcho2 was rated higher than cEcho1, with a mean respective lesion conspicuity of 5.5/4.3 (p < 0.005) and diagnostic confidence of 5.4/4.4 (p < 0.005). cEcho2 was favored over all echoes for its diagnostic reliability, particularly in regions close to the head coil. This work concludes that DE-EPI DWI is a useful alternative to conventional single-echo EPI DWI, whereby Echo2 and cEcho2 allows for improved lesion detection and overall higher diagnostic confidence.
format Online
Article
Text
id pubmed-4466387
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-44663872015-06-22 Intensity-Corrected Dual-Echo Echo-Planar Imaging (DE-EPI) for Improved Pediatric Brain Diffusion Imaging Yeom, Kristen W. Straka, Matus Iv, Michael Moseley, Michael E. Barnes, Patrick D. Skare, Stefan Holdsworth, Samantha J. PLoS One Research Article Here we investigate the utility of a dual-echo Echo-Planar Imaging (DE-EPI) Diffusion Weighted Imaging (DWI) approach to improve lesion conspicuity in pediatric imaging. This method delivers two ‘echo images’ for one diffusion-preparation period. We also demonstrate how the echoes can be utilized to remove transmit/receive coil-induced and static magnetic field intensity modulations on both echo images, which often mimic pathology and thereby pose diagnostic challenges. DE-EPI DWI data were acquired in 18 pediatric patients with abnormal diffusion lesions, and 46 pediatric patient controls at 3T. Echo1 [TE = 45ms] and Echo2 [TE = 86ms] were corrected for signal intensity variation across the images by exploiting the images equivalent coil-sensitivity and susceptibility-induced modulations. Two neuroradiologists independently reviewed Echo1 and Echo2 and their intensity-corrected variants (cEcho1 and cEcho2) on a 7-point Likert scale, with grading on lesion conspicuity diagnostic confidence. The apparent diffusion coefficient (ADC) map from Echo1 was used to validate presence of true pathology. Echo2 was unanimously favored over Echo1 for its sensitivity for detecting acute brain injury, with a mean respective lesion conspicuity of 5.7/4.4 (p < 0.005) and diagnostic confidence of 5.1/4.3 (p = 0.025). cEcho2 was rated higher than cEcho1, with a mean respective lesion conspicuity of 5.5/4.3 (p < 0.005) and diagnostic confidence of 5.4/4.4 (p < 0.005). cEcho2 was favored over all echoes for its diagnostic reliability, particularly in regions close to the head coil. This work concludes that DE-EPI DWI is a useful alternative to conventional single-echo EPI DWI, whereby Echo2 and cEcho2 allows for improved lesion detection and overall higher diagnostic confidence. Public Library of Science 2015-06-12 /pmc/articles/PMC4466387/ /pubmed/26069959 http://dx.doi.org/10.1371/journal.pone.0129325 Text en © 2015 Yeom et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Yeom, Kristen W.
Straka, Matus
Iv, Michael
Moseley, Michael E.
Barnes, Patrick D.
Skare, Stefan
Holdsworth, Samantha J.
Intensity-Corrected Dual-Echo Echo-Planar Imaging (DE-EPI) for Improved Pediatric Brain Diffusion Imaging
title Intensity-Corrected Dual-Echo Echo-Planar Imaging (DE-EPI) for Improved Pediatric Brain Diffusion Imaging
title_full Intensity-Corrected Dual-Echo Echo-Planar Imaging (DE-EPI) for Improved Pediatric Brain Diffusion Imaging
title_fullStr Intensity-Corrected Dual-Echo Echo-Planar Imaging (DE-EPI) for Improved Pediatric Brain Diffusion Imaging
title_full_unstemmed Intensity-Corrected Dual-Echo Echo-Planar Imaging (DE-EPI) for Improved Pediatric Brain Diffusion Imaging
title_short Intensity-Corrected Dual-Echo Echo-Planar Imaging (DE-EPI) for Improved Pediatric Brain Diffusion Imaging
title_sort intensity-corrected dual-echo echo-planar imaging (de-epi) for improved pediatric brain diffusion imaging
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4466387/
https://www.ncbi.nlm.nih.gov/pubmed/26069959
http://dx.doi.org/10.1371/journal.pone.0129325
work_keys_str_mv AT yeomkristenw intensitycorrecteddualechoechoplanarimagingdeepiforimprovedpediatricbraindiffusionimaging
AT strakamatus intensitycorrecteddualechoechoplanarimagingdeepiforimprovedpediatricbraindiffusionimaging
AT ivmichael intensitycorrecteddualechoechoplanarimagingdeepiforimprovedpediatricbraindiffusionimaging
AT moseleymichaele intensitycorrecteddualechoechoplanarimagingdeepiforimprovedpediatricbraindiffusionimaging
AT barnespatrickd intensitycorrecteddualechoechoplanarimagingdeepiforimprovedpediatricbraindiffusionimaging
AT skarestefan intensitycorrecteddualechoechoplanarimagingdeepiforimprovedpediatricbraindiffusionimaging
AT holdsworthsamanthaj intensitycorrecteddualechoechoplanarimagingdeepiforimprovedpediatricbraindiffusionimaging