Histogram-Based Calibration Method for Pipeline ADCs
Measurement and calibration of an analog-to-digital converter (ADC) using a histogram-based method requires a large volume of data and a long test duration, especially for a high resolution ADC. A fast and accurate calibration method for pipelined ADCs is proposed in this research. The proposed cali...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4466524/ https://www.ncbi.nlm.nih.gov/pubmed/26070196 http://dx.doi.org/10.1371/journal.pone.0129736 |
_version_ | 1782376234741661696 |
---|---|
author | Son, Hyeonuk Jang, Jaewon Kim, Heetae Kang, Sungho |
author_facet | Son, Hyeonuk Jang, Jaewon Kim, Heetae Kang, Sungho |
author_sort | Son, Hyeonuk |
collection | PubMed |
description | Measurement and calibration of an analog-to-digital converter (ADC) using a histogram-based method requires a large volume of data and a long test duration, especially for a high resolution ADC. A fast and accurate calibration method for pipelined ADCs is proposed in this research. The proposed calibration method composes histograms through the outputs of each stage and calculates error sources. The digitized outputs of a stage are influenced directly by the operation of the prior stage, so the results of the histogram provide the information of errors in the prior stage. The composed histograms reduce the required samples and thus calibration time being implemented by simple modules. For 14-bit resolution pipelined ADC, the measured maximum integral non-linearity (INL) is improved from 6.78 to 0.52 LSB, and the spurious-free dynamic range (SFDR) and signal-to-noise-and-distortion ratio (SNDR) are improved from 67.0 to 106.2dB and from 65.6 to 84.8dB, respectively. |
format | Online Article Text |
id | pubmed-4466524 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-44665242015-06-22 Histogram-Based Calibration Method for Pipeline ADCs Son, Hyeonuk Jang, Jaewon Kim, Heetae Kang, Sungho PLoS One Research Article Measurement and calibration of an analog-to-digital converter (ADC) using a histogram-based method requires a large volume of data and a long test duration, especially for a high resolution ADC. A fast and accurate calibration method for pipelined ADCs is proposed in this research. The proposed calibration method composes histograms through the outputs of each stage and calculates error sources. The digitized outputs of a stage are influenced directly by the operation of the prior stage, so the results of the histogram provide the information of errors in the prior stage. The composed histograms reduce the required samples and thus calibration time being implemented by simple modules. For 14-bit resolution pipelined ADC, the measured maximum integral non-linearity (INL) is improved from 6.78 to 0.52 LSB, and the spurious-free dynamic range (SFDR) and signal-to-noise-and-distortion ratio (SNDR) are improved from 67.0 to 106.2dB and from 65.6 to 84.8dB, respectively. Public Library of Science 2015-06-12 /pmc/articles/PMC4466524/ /pubmed/26070196 http://dx.doi.org/10.1371/journal.pone.0129736 Text en © 2015 Son et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Son, Hyeonuk Jang, Jaewon Kim, Heetae Kang, Sungho Histogram-Based Calibration Method for Pipeline ADCs |
title | Histogram-Based Calibration Method for Pipeline ADCs |
title_full | Histogram-Based Calibration Method for Pipeline ADCs |
title_fullStr | Histogram-Based Calibration Method for Pipeline ADCs |
title_full_unstemmed | Histogram-Based Calibration Method for Pipeline ADCs |
title_short | Histogram-Based Calibration Method for Pipeline ADCs |
title_sort | histogram-based calibration method for pipeline adcs |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4466524/ https://www.ncbi.nlm.nih.gov/pubmed/26070196 http://dx.doi.org/10.1371/journal.pone.0129736 |
work_keys_str_mv | AT sonhyeonuk histogrambasedcalibrationmethodforpipelineadcs AT jangjaewon histogrambasedcalibrationmethodforpipelineadcs AT kimheetae histogrambasedcalibrationmethodforpipelineadcs AT kangsungho histogrambasedcalibrationmethodforpipelineadcs |