Cargando…

Trial-to-trial latency variability of somatosensory evoked potentials as a prognostic indicator for surgical management of cervical spondylotic myelopathy

BACKGROUND: Early detection of neural conductivity changes at the compressed spinal cord is important for predicting the surgical outcomes of patients with cervical spondylotic myelopathy (CSM). The prognostic value of median nerve somatosensory evoked potential (SEP) has been proposed previously. T...

Descripción completa

Detalles Bibliográficos
Autores principales: Cui, Hongyan, Wang, Yazhou, Li, Xiang, Xie, Xiaobo, Xu, Shengpu, Hu, Yong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4467682/
https://www.ncbi.nlm.nih.gov/pubmed/26021604
http://dx.doi.org/10.1186/s12984-015-0042-4
_version_ 1782376402761285632
author Cui, Hongyan
Wang, Yazhou
Li, Xiang
Xie, Xiaobo
Xu, Shengpu
Hu, Yong
author_facet Cui, Hongyan
Wang, Yazhou
Li, Xiang
Xie, Xiaobo
Xu, Shengpu
Hu, Yong
author_sort Cui, Hongyan
collection PubMed
description BACKGROUND: Early detection of neural conductivity changes at the compressed spinal cord is important for predicting the surgical outcomes of patients with cervical spondylotic myelopathy (CSM). The prognostic value of median nerve somatosensory evoked potential (SEP) has been proposed previously. The present prospective study evaluates the use of trial-to-trial variability in SEP as a valuable predictor of neurological recovery after surgery of CSM. METHODS: A total of 35 CSM patients who underwent surgery with up to 6-month follow-up were recruited in this study. SEP signals were recorded preoperatively. The single trial SEP was extracted by a newly developed second-order blind identification method. The postoperative recovery was assessed using the modified Japanese Orthopaedic Association. The correlation between the latency variability of trial-to-trial SEP and post-operative recovery ratio was analyzed. The prognostic value of trial-to-trial SEP for CSM was evaluated using a receiver operator characteristic curve which can accurately reflect the relationship between sensitivity and specificity of a diagnostic method and represent the accuracy of prognosis. RESULTS: The correlation coefficient of trial-to-trial latency variability and the 6-month recovery ratio was statistically significant (r = −0.82, P < 0.01). The trial-to-trial SEP had a higher prognostic accuracy (AUC = 0.928, P < 0.001) with an optimal prognostic value of 9.25 % compared with averaged SEP when the threshold of recovery ratio was 40 %, and was more sensitive (93.80 %) than the averaged SEP (43.80 %). CONCLUSIONS: These findings indicate that the latency variability of trial-to-trial SEP reflect the recovery ratio of CSM patients after surgery. It is suggested that the latency variability of trial-to-trial SEP is useful for predicting the surgical outcomes for patients with CSM, which would be a potential indication of surgical treatment for CSM to help decision making of surgical planning for CSM patients. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12984-015-0042-4) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-4467682
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-44676822015-06-16 Trial-to-trial latency variability of somatosensory evoked potentials as a prognostic indicator for surgical management of cervical spondylotic myelopathy Cui, Hongyan Wang, Yazhou Li, Xiang Xie, Xiaobo Xu, Shengpu Hu, Yong J Neuroeng Rehabil Research BACKGROUND: Early detection of neural conductivity changes at the compressed spinal cord is important for predicting the surgical outcomes of patients with cervical spondylotic myelopathy (CSM). The prognostic value of median nerve somatosensory evoked potential (SEP) has been proposed previously. The present prospective study evaluates the use of trial-to-trial variability in SEP as a valuable predictor of neurological recovery after surgery of CSM. METHODS: A total of 35 CSM patients who underwent surgery with up to 6-month follow-up were recruited in this study. SEP signals were recorded preoperatively. The single trial SEP was extracted by a newly developed second-order blind identification method. The postoperative recovery was assessed using the modified Japanese Orthopaedic Association. The correlation between the latency variability of trial-to-trial SEP and post-operative recovery ratio was analyzed. The prognostic value of trial-to-trial SEP for CSM was evaluated using a receiver operator characteristic curve which can accurately reflect the relationship between sensitivity and specificity of a diagnostic method and represent the accuracy of prognosis. RESULTS: The correlation coefficient of trial-to-trial latency variability and the 6-month recovery ratio was statistically significant (r = −0.82, P < 0.01). The trial-to-trial SEP had a higher prognostic accuracy (AUC = 0.928, P < 0.001) with an optimal prognostic value of 9.25 % compared with averaged SEP when the threshold of recovery ratio was 40 %, and was more sensitive (93.80 %) than the averaged SEP (43.80 %). CONCLUSIONS: These findings indicate that the latency variability of trial-to-trial SEP reflect the recovery ratio of CSM patients after surgery. It is suggested that the latency variability of trial-to-trial SEP is useful for predicting the surgical outcomes for patients with CSM, which would be a potential indication of surgical treatment for CSM to help decision making of surgical planning for CSM patients. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12984-015-0042-4) contains supplementary material, which is available to authorized users. BioMed Central 2015-05-29 /pmc/articles/PMC4467682/ /pubmed/26021604 http://dx.doi.org/10.1186/s12984-015-0042-4 Text en © Cui et al.; licensee BioMed Central. 2015 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Cui, Hongyan
Wang, Yazhou
Li, Xiang
Xie, Xiaobo
Xu, Shengpu
Hu, Yong
Trial-to-trial latency variability of somatosensory evoked potentials as a prognostic indicator for surgical management of cervical spondylotic myelopathy
title Trial-to-trial latency variability of somatosensory evoked potentials as a prognostic indicator for surgical management of cervical spondylotic myelopathy
title_full Trial-to-trial latency variability of somatosensory evoked potentials as a prognostic indicator for surgical management of cervical spondylotic myelopathy
title_fullStr Trial-to-trial latency variability of somatosensory evoked potentials as a prognostic indicator for surgical management of cervical spondylotic myelopathy
title_full_unstemmed Trial-to-trial latency variability of somatosensory evoked potentials as a prognostic indicator for surgical management of cervical spondylotic myelopathy
title_short Trial-to-trial latency variability of somatosensory evoked potentials as a prognostic indicator for surgical management of cervical spondylotic myelopathy
title_sort trial-to-trial latency variability of somatosensory evoked potentials as a prognostic indicator for surgical management of cervical spondylotic myelopathy
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4467682/
https://www.ncbi.nlm.nih.gov/pubmed/26021604
http://dx.doi.org/10.1186/s12984-015-0042-4
work_keys_str_mv AT cuihongyan trialtotriallatencyvariabilityofsomatosensoryevokedpotentialsasaprognosticindicatorforsurgicalmanagementofcervicalspondyloticmyelopathy
AT wangyazhou trialtotriallatencyvariabilityofsomatosensoryevokedpotentialsasaprognosticindicatorforsurgicalmanagementofcervicalspondyloticmyelopathy
AT lixiang trialtotriallatencyvariabilityofsomatosensoryevokedpotentialsasaprognosticindicatorforsurgicalmanagementofcervicalspondyloticmyelopathy
AT xiexiaobo trialtotriallatencyvariabilityofsomatosensoryevokedpotentialsasaprognosticindicatorforsurgicalmanagementofcervicalspondyloticmyelopathy
AT xushengpu trialtotriallatencyvariabilityofsomatosensoryevokedpotentialsasaprognosticindicatorforsurgicalmanagementofcervicalspondyloticmyelopathy
AT huyong trialtotriallatencyvariabilityofsomatosensoryevokedpotentialsasaprognosticindicatorforsurgicalmanagementofcervicalspondyloticmyelopathy