Cargando…

Direct assessment of 3D foot bone kinematics using biplanar X-ray fluoroscopy and an automatic model registration method

BACKGROUND: Quantifying detailed 3-dimensional (3D) kinematics of the foot in contact with the ground during locomotion is crucial for understanding the biomechanical functions of the complex musculoskeletal structure of the foot. Biplanar X-ray fluoroscopic systems and model-based registration tech...

Descripción completa

Detalles Bibliográficos
Autores principales: Ito, Kohta, Hosoda, Koh, Shimizu, Masahiro, Ikemoto, Shuhei, Kume, Shinnosuke, Nagura, Takeo, Imanishi, Nobuaki, Aiso, Sadakazu, Jinzaki, Masahiro, Ogihara, Naomichi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4470042/
https://www.ncbi.nlm.nih.gov/pubmed/26085843
http://dx.doi.org/10.1186/s13047-015-0079-4
_version_ 1782376694199353344
author Ito, Kohta
Hosoda, Koh
Shimizu, Masahiro
Ikemoto, Shuhei
Kume, Shinnosuke
Nagura, Takeo
Imanishi, Nobuaki
Aiso, Sadakazu
Jinzaki, Masahiro
Ogihara, Naomichi
author_facet Ito, Kohta
Hosoda, Koh
Shimizu, Masahiro
Ikemoto, Shuhei
Kume, Shinnosuke
Nagura, Takeo
Imanishi, Nobuaki
Aiso, Sadakazu
Jinzaki, Masahiro
Ogihara, Naomichi
author_sort Ito, Kohta
collection PubMed
description BACKGROUND: Quantifying detailed 3-dimensional (3D) kinematics of the foot in contact with the ground during locomotion is crucial for understanding the biomechanical functions of the complex musculoskeletal structure of the foot. Biplanar X-ray fluoroscopic systems and model-based registration techniques have recently been employed to capture and visualise 3D foot bone movements in vivo, but such techniques have generally been performed manually. In the present study, we developed an automatic model-registration method with biplanar fluoroscopy for accurate measurement of 3D movements of the skeletal foot. METHODS: Three-dimensional surface models of foot bones were generated prior to motion measurement based on computed tomography. The bone models generated were then registered to biplanar fluoroscopic images in a frame-by-frame manner using an optimisation technique, to maximise similarity measures between occluding contours of the bone surface models with edge-enhanced fluoroscopic images, while avoiding mutual penetration of bones. A template-matching method was also introduced to estimate the amount of bone translation and rotation prior to automatic registration. RESULTS: We analysed 3D skeletal movements of a cadaver foot mobilized by a robotic gait simulator. The 3D kinematics of the calcaneus, talus, navicular and cuboid in the stance phase of the gait were successfully reconstructed and quantified using the proposed model-registration method. The accuracy of bone registration was evaluated as 0.27 ± 0.19 mm and 0.24 ± 0.19° (mean ± standard deviation) in translation and rotation, respectively, under static conditions, and 0.36 ± 0.19 mm and 0.42 ± 0.30° in translation and rotation, respectively, under dynamic conditions. CONCLUSIONS: The measurement was confirmed to be sufficiently accurate for actual analysis of foot kinematics. The proposed method may serve as an effective tool for understanding the biomechanical function of the human foot during locomotion.
format Online
Article
Text
id pubmed-4470042
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-44700422015-06-18 Direct assessment of 3D foot bone kinematics using biplanar X-ray fluoroscopy and an automatic model registration method Ito, Kohta Hosoda, Koh Shimizu, Masahiro Ikemoto, Shuhei Kume, Shinnosuke Nagura, Takeo Imanishi, Nobuaki Aiso, Sadakazu Jinzaki, Masahiro Ogihara, Naomichi J Foot Ankle Res Research BACKGROUND: Quantifying detailed 3-dimensional (3D) kinematics of the foot in contact with the ground during locomotion is crucial for understanding the biomechanical functions of the complex musculoskeletal structure of the foot. Biplanar X-ray fluoroscopic systems and model-based registration techniques have recently been employed to capture and visualise 3D foot bone movements in vivo, but such techniques have generally been performed manually. In the present study, we developed an automatic model-registration method with biplanar fluoroscopy for accurate measurement of 3D movements of the skeletal foot. METHODS: Three-dimensional surface models of foot bones were generated prior to motion measurement based on computed tomography. The bone models generated were then registered to biplanar fluoroscopic images in a frame-by-frame manner using an optimisation technique, to maximise similarity measures between occluding contours of the bone surface models with edge-enhanced fluoroscopic images, while avoiding mutual penetration of bones. A template-matching method was also introduced to estimate the amount of bone translation and rotation prior to automatic registration. RESULTS: We analysed 3D skeletal movements of a cadaver foot mobilized by a robotic gait simulator. The 3D kinematics of the calcaneus, talus, navicular and cuboid in the stance phase of the gait were successfully reconstructed and quantified using the proposed model-registration method. The accuracy of bone registration was evaluated as 0.27 ± 0.19 mm and 0.24 ± 0.19° (mean ± standard deviation) in translation and rotation, respectively, under static conditions, and 0.36 ± 0.19 mm and 0.42 ± 0.30° in translation and rotation, respectively, under dynamic conditions. CONCLUSIONS: The measurement was confirmed to be sufficiently accurate for actual analysis of foot kinematics. The proposed method may serve as an effective tool for understanding the biomechanical function of the human foot during locomotion. BioMed Central 2015-06-10 /pmc/articles/PMC4470042/ /pubmed/26085843 http://dx.doi.org/10.1186/s13047-015-0079-4 Text en © Ito et al. 2015 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Ito, Kohta
Hosoda, Koh
Shimizu, Masahiro
Ikemoto, Shuhei
Kume, Shinnosuke
Nagura, Takeo
Imanishi, Nobuaki
Aiso, Sadakazu
Jinzaki, Masahiro
Ogihara, Naomichi
Direct assessment of 3D foot bone kinematics using biplanar X-ray fluoroscopy and an automatic model registration method
title Direct assessment of 3D foot bone kinematics using biplanar X-ray fluoroscopy and an automatic model registration method
title_full Direct assessment of 3D foot bone kinematics using biplanar X-ray fluoroscopy and an automatic model registration method
title_fullStr Direct assessment of 3D foot bone kinematics using biplanar X-ray fluoroscopy and an automatic model registration method
title_full_unstemmed Direct assessment of 3D foot bone kinematics using biplanar X-ray fluoroscopy and an automatic model registration method
title_short Direct assessment of 3D foot bone kinematics using biplanar X-ray fluoroscopy and an automatic model registration method
title_sort direct assessment of 3d foot bone kinematics using biplanar x-ray fluoroscopy and an automatic model registration method
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4470042/
https://www.ncbi.nlm.nih.gov/pubmed/26085843
http://dx.doi.org/10.1186/s13047-015-0079-4
work_keys_str_mv AT itokohta directassessmentof3dfootbonekinematicsusingbiplanarxrayfluoroscopyandanautomaticmodelregistrationmethod
AT hosodakoh directassessmentof3dfootbonekinematicsusingbiplanarxrayfluoroscopyandanautomaticmodelregistrationmethod
AT shimizumasahiro directassessmentof3dfootbonekinematicsusingbiplanarxrayfluoroscopyandanautomaticmodelregistrationmethod
AT ikemotoshuhei directassessmentof3dfootbonekinematicsusingbiplanarxrayfluoroscopyandanautomaticmodelregistrationmethod
AT kumeshinnosuke directassessmentof3dfootbonekinematicsusingbiplanarxrayfluoroscopyandanautomaticmodelregistrationmethod
AT naguratakeo directassessmentof3dfootbonekinematicsusingbiplanarxrayfluoroscopyandanautomaticmodelregistrationmethod
AT imanishinobuaki directassessmentof3dfootbonekinematicsusingbiplanarxrayfluoroscopyandanautomaticmodelregistrationmethod
AT aisosadakazu directassessmentof3dfootbonekinematicsusingbiplanarxrayfluoroscopyandanautomaticmodelregistrationmethod
AT jinzakimasahiro directassessmentof3dfootbonekinematicsusingbiplanarxrayfluoroscopyandanautomaticmodelregistrationmethod
AT ogiharanaomichi directassessmentof3dfootbonekinematicsusingbiplanarxrayfluoroscopyandanautomaticmodelregistrationmethod