Cargando…

Xpert® MTB/RIF assay for pulmonary tuberculosis and rifampicin resistance in adults

BACKGROUND: Accurate, rapid detection of tuberculosis (TB) and TB drug resistance is critical for improving patient care and decreasing TB transmission. Xpert® MTB/RIF assay is an automated test that can detect both TB and rifampicin resistance, generally within two hours after starting the test, wi...

Descripción completa

Detalles Bibliográficos
Autores principales: Steingart, Karen R, Schiller, Ian, Horne, David J, Pai, Madhukar, Boehme, Catharina C, Dendukuri, Nandini
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons, Ltd 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4470349/
https://www.ncbi.nlm.nih.gov/pubmed/24448973
http://dx.doi.org/10.1002/14651858.CD009593.pub3
_version_ 1782376754555387904
author Steingart, Karen R
Schiller, Ian
Horne, David J
Pai, Madhukar
Boehme, Catharina C
Dendukuri, Nandini
author_facet Steingart, Karen R
Schiller, Ian
Horne, David J
Pai, Madhukar
Boehme, Catharina C
Dendukuri, Nandini
author_sort Steingart, Karen R
collection PubMed
description BACKGROUND: Accurate, rapid detection of tuberculosis (TB) and TB drug resistance is critical for improving patient care and decreasing TB transmission. Xpert® MTB/RIF assay is an automated test that can detect both TB and rifampicin resistance, generally within two hours after starting the test, with minimal hands‐on technical time. The World Health Organization (WHO) issued initial recommendations on Xpert® MTB/RIF in early 2011. A Cochrane Review on the diagnostic accuracy of Xpert® MTB/RIF for pulmonary TB and rifampicin resistance was published January 2013. We performed this updated Cochrane Review as part of a WHO process to develop updated guidelines on the use of the test. OBJECTIVES: To assess the diagnostic accuracy of Xpert® MTB/RIF for pulmonary TB (TB detection), where Xpert® MTB/RIF was used as both an initial test replacing microscopy and an add‐on test following a negative smear microscopy result. To assess the diagnostic accuracy of Xpert® MTB/RIF for rifampicin resistance detection, where Xpert® MTB/RIF was used as the initial test replacing culture‐based drug susceptibility testing (DST). The populations of interest were adults presumed to have pulmonary, rifampicin‐resistant or multidrug‐resistant TB (MDR‐TB), with or without HIV infection. The settings of interest were intermediate‐ and peripheral‐level laboratories. The latter may be associated with primary health care facilities. SEARCH METHODS: We searched for publications in any language up to 7 February 2013 in the following databases: Cochrane Infectious Diseases Group Specialized Register; MEDLINE; EMBASE; ISI Web of Knowledge; MEDION; LILACS; BIOSIS; and SCOPUS. We also searched the metaRegister of Controlled Trials (mRCT) and the search portal of the WHO International Clinical Trials Registry Platform to identify ongoing trials. SELECTION CRITERIA: We included randomized controlled trials, cross‐sectional studies, and cohort studies using respiratory specimens that allowed for extraction of data evaluating Xpert® MTB/RIF against the reference standard. We excluded gastric fluid specimens. The reference standard for TB was culture and for rifampicin resistance was phenotypic culture‐based DST. DATA COLLECTION AND ANALYSIS: For each study, two review authors independently extracted data using a standardized form. When possible, we extracted data for subgroups by smear and HIV status. We assessed the quality of studies using QUADAS‐2 and carried out meta‐analyses to estimate pooled sensitivity and specificity of Xpert® MTB/RIF separately for TB detection and rifampicin resistance detection. For TB detection, we performed the majority of analyses using a bivariate random‐effects model and compared the sensitivity of Xpert® MTB/RIF and smear microscopy against culture as reference standard. For rifampicin resistance detection, we undertook univariate meta‐analyses for sensitivity and specificity separately to include studies in which no rifampicin resistance was detected. MAIN RESULTS: We included 27 unique studies (integrating nine new studies) involving 9557 participants. Sixteen studies (59%) were performed in low‐ or middle‐income countries. For all QUADAS‐2 domains, most studies were at low risk of bias and low concern regarding applicability. As an initial test replacing smear microscopy, Xpert® MTB/RIF pooled sensitivity was 89% [95% Credible Interval (CrI) 85% to 92%] and pooled specificity 99% (95% CrI 98% to 99%), (22 studies, 8998 participants: 2953 confirmed TB, 6045 non‐TB). As an add‐on test following a negative smear microscopy result, Xpert®MTB/RIF pooled sensitivity was 67% (95% CrI 60% to 74%) and pooled specificity 99% (95% CrI 98% to 99%; 21 studies, 6950 participants). For smear‐positive, culture‐positive TB, Xpert® MTB/RIF pooled sensitivity was 98% (95% CrI 97% to 99%; 21 studies, 1936 participants). For people with HIV infection, Xpert® MTB/RIF pooled sensitivity was 79% (95% CrI 70% to 86%; seven studies, 1789 participants), and for people without HIV infection, it was 86% (95% CrI 76% to 92%; seven studies, 1470 participants). Among 180 specimens with nontuberculous mycobacteria (NTM), Xpert® MTB/RIF was positive in only one specimen that grew NTM (14 studies, 2626 participants). Comparison with smear microscopy In comparison with smear microscopy, Xpert® MTB/RIF increased TB detection among culture‐confirmed cases by 23% (95% CrI 15% to 32%; 21 studies, 8880 participants). For TB detection, if pooled sensitivity estimates for Xpert® MTB/RIF and smear microscopy are applied to a hypothetical cohort of 1000 patients where 10% of those with symptoms have TB, Xpert® MTB/RIF will diagnose 88 cases and miss 12 cases, whereas sputum microscopy will diagnose 65 cases and miss 35 cases. Rifampicin resistance For rifampicin resistance detection, Xpert® MTB/RIF pooled sensitivity was 95% (95% CrI 90% to 97%; 17 studies, 555 rifampicin resistance positives) and pooled specificity was 98% (95% CrI 97% to 99%; 24 studies, 2411 rifampicin resistance negatives). For rifampicin resistance detection, if the pooled accuracy estimates for Xpert® MTB/RIF are applied to a hypothetical cohort of 1000 individuals where 15% of those with symptoms are rifampicin resistant, Xpert® MTB/RIF would correctly identify 143 individuals as rifampicin resistant and miss eight cases, and correctly identify 833 individuals as rifampicin susceptible and misclassify 17 individuals as resistant. Where 5% of those with symptoms are rifampicin resistant, Xpert® MTB/RIF would correctly identify 48 individuals as rifampicin resistant and miss three cases and correctly identify 931 individuals as rifampicin susceptible and misclassify 19 individuals as resistant. AUTHORS' CONCLUSIONS: In adults thought to have TB, with or without HIV infection, Xpert® MTB/RIF is sensitive and specific. Compared with smear microscopy, Xpert® MTB/RIF substantially increases TB detection among culture‐confirmed cases. Xpert® MTB/RIF has higher sensitivity for TB detection in smear‐positive than smear‐negative patients. Nonetheless, this test may be valuable as an add‐on test following smear microscopy in patients previously found to be smear‐negative. For rifampicin resistance detection, Xpert® MTB/RIF provides accurate results and can allow rapid initiation of MDR‐TB treatment, pending results from conventional culture and DST. The tests are expensive, so current research evaluating the use of Xpert® MTB/RIF in TB programmes in high TB burden settings will help evaluate how this investment may help start treatment promptly and improve outcomes.
format Online
Article
Text
id pubmed-4470349
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher John Wiley & Sons, Ltd
record_format MEDLINE/PubMed
spelling pubmed-44703492015-06-29 Xpert® MTB/RIF assay for pulmonary tuberculosis and rifampicin resistance in adults Steingart, Karen R Schiller, Ian Horne, David J Pai, Madhukar Boehme, Catharina C Dendukuri, Nandini Cochrane Database Syst Rev Medicine General & Introductory Medical Sciences BACKGROUND: Accurate, rapid detection of tuberculosis (TB) and TB drug resistance is critical for improving patient care and decreasing TB transmission. Xpert® MTB/RIF assay is an automated test that can detect both TB and rifampicin resistance, generally within two hours after starting the test, with minimal hands‐on technical time. The World Health Organization (WHO) issued initial recommendations on Xpert® MTB/RIF in early 2011. A Cochrane Review on the diagnostic accuracy of Xpert® MTB/RIF for pulmonary TB and rifampicin resistance was published January 2013. We performed this updated Cochrane Review as part of a WHO process to develop updated guidelines on the use of the test. OBJECTIVES: To assess the diagnostic accuracy of Xpert® MTB/RIF for pulmonary TB (TB detection), where Xpert® MTB/RIF was used as both an initial test replacing microscopy and an add‐on test following a negative smear microscopy result. To assess the diagnostic accuracy of Xpert® MTB/RIF for rifampicin resistance detection, where Xpert® MTB/RIF was used as the initial test replacing culture‐based drug susceptibility testing (DST). The populations of interest were adults presumed to have pulmonary, rifampicin‐resistant or multidrug‐resistant TB (MDR‐TB), with or without HIV infection. The settings of interest were intermediate‐ and peripheral‐level laboratories. The latter may be associated with primary health care facilities. SEARCH METHODS: We searched for publications in any language up to 7 February 2013 in the following databases: Cochrane Infectious Diseases Group Specialized Register; MEDLINE; EMBASE; ISI Web of Knowledge; MEDION; LILACS; BIOSIS; and SCOPUS. We also searched the metaRegister of Controlled Trials (mRCT) and the search portal of the WHO International Clinical Trials Registry Platform to identify ongoing trials. SELECTION CRITERIA: We included randomized controlled trials, cross‐sectional studies, and cohort studies using respiratory specimens that allowed for extraction of data evaluating Xpert® MTB/RIF against the reference standard. We excluded gastric fluid specimens. The reference standard for TB was culture and for rifampicin resistance was phenotypic culture‐based DST. DATA COLLECTION AND ANALYSIS: For each study, two review authors independently extracted data using a standardized form. When possible, we extracted data for subgroups by smear and HIV status. We assessed the quality of studies using QUADAS‐2 and carried out meta‐analyses to estimate pooled sensitivity and specificity of Xpert® MTB/RIF separately for TB detection and rifampicin resistance detection. For TB detection, we performed the majority of analyses using a bivariate random‐effects model and compared the sensitivity of Xpert® MTB/RIF and smear microscopy against culture as reference standard. For rifampicin resistance detection, we undertook univariate meta‐analyses for sensitivity and specificity separately to include studies in which no rifampicin resistance was detected. MAIN RESULTS: We included 27 unique studies (integrating nine new studies) involving 9557 participants. Sixteen studies (59%) were performed in low‐ or middle‐income countries. For all QUADAS‐2 domains, most studies were at low risk of bias and low concern regarding applicability. As an initial test replacing smear microscopy, Xpert® MTB/RIF pooled sensitivity was 89% [95% Credible Interval (CrI) 85% to 92%] and pooled specificity 99% (95% CrI 98% to 99%), (22 studies, 8998 participants: 2953 confirmed TB, 6045 non‐TB). As an add‐on test following a negative smear microscopy result, Xpert®MTB/RIF pooled sensitivity was 67% (95% CrI 60% to 74%) and pooled specificity 99% (95% CrI 98% to 99%; 21 studies, 6950 participants). For smear‐positive, culture‐positive TB, Xpert® MTB/RIF pooled sensitivity was 98% (95% CrI 97% to 99%; 21 studies, 1936 participants). For people with HIV infection, Xpert® MTB/RIF pooled sensitivity was 79% (95% CrI 70% to 86%; seven studies, 1789 participants), and for people without HIV infection, it was 86% (95% CrI 76% to 92%; seven studies, 1470 participants). Among 180 specimens with nontuberculous mycobacteria (NTM), Xpert® MTB/RIF was positive in only one specimen that grew NTM (14 studies, 2626 participants). Comparison with smear microscopy In comparison with smear microscopy, Xpert® MTB/RIF increased TB detection among culture‐confirmed cases by 23% (95% CrI 15% to 32%; 21 studies, 8880 participants). For TB detection, if pooled sensitivity estimates for Xpert® MTB/RIF and smear microscopy are applied to a hypothetical cohort of 1000 patients where 10% of those with symptoms have TB, Xpert® MTB/RIF will diagnose 88 cases and miss 12 cases, whereas sputum microscopy will diagnose 65 cases and miss 35 cases. Rifampicin resistance For rifampicin resistance detection, Xpert® MTB/RIF pooled sensitivity was 95% (95% CrI 90% to 97%; 17 studies, 555 rifampicin resistance positives) and pooled specificity was 98% (95% CrI 97% to 99%; 24 studies, 2411 rifampicin resistance negatives). For rifampicin resistance detection, if the pooled accuracy estimates for Xpert® MTB/RIF are applied to a hypothetical cohort of 1000 individuals where 15% of those with symptoms are rifampicin resistant, Xpert® MTB/RIF would correctly identify 143 individuals as rifampicin resistant and miss eight cases, and correctly identify 833 individuals as rifampicin susceptible and misclassify 17 individuals as resistant. Where 5% of those with symptoms are rifampicin resistant, Xpert® MTB/RIF would correctly identify 48 individuals as rifampicin resistant and miss three cases and correctly identify 931 individuals as rifampicin susceptible and misclassify 19 individuals as resistant. AUTHORS' CONCLUSIONS: In adults thought to have TB, with or without HIV infection, Xpert® MTB/RIF is sensitive and specific. Compared with smear microscopy, Xpert® MTB/RIF substantially increases TB detection among culture‐confirmed cases. Xpert® MTB/RIF has higher sensitivity for TB detection in smear‐positive than smear‐negative patients. Nonetheless, this test may be valuable as an add‐on test following smear microscopy in patients previously found to be smear‐negative. For rifampicin resistance detection, Xpert® MTB/RIF provides accurate results and can allow rapid initiation of MDR‐TB treatment, pending results from conventional culture and DST. The tests are expensive, so current research evaluating the use of Xpert® MTB/RIF in TB programmes in high TB burden settings will help evaluate how this investment may help start treatment promptly and improve outcomes. John Wiley & Sons, Ltd 2014-01-21 /pmc/articles/PMC4470349/ /pubmed/24448973 http://dx.doi.org/10.1002/14651858.CD009593.pub3 Text en Copyright © 2015 The Authors. Cochrane Database of Systematic Reviews published by John Wiley & Sons, Ltd. on behalf of The Cochrane Collaboration. https://creativecommons.org/licenses/by-nc/2.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial License, which allows remixing, tweaking, and building upon the original work non-commercially, and although the new works must also acknowledge the original work and be non-commercial, derivative works don’t have to be licensed under the same terms.
spellingShingle Medicine General & Introductory Medical Sciences
Steingart, Karen R
Schiller, Ian
Horne, David J
Pai, Madhukar
Boehme, Catharina C
Dendukuri, Nandini
Xpert® MTB/RIF assay for pulmonary tuberculosis and rifampicin resistance in adults
title Xpert® MTB/RIF assay for pulmonary tuberculosis and rifampicin resistance in adults
title_full Xpert® MTB/RIF assay for pulmonary tuberculosis and rifampicin resistance in adults
title_fullStr Xpert® MTB/RIF assay for pulmonary tuberculosis and rifampicin resistance in adults
title_full_unstemmed Xpert® MTB/RIF assay for pulmonary tuberculosis and rifampicin resistance in adults
title_short Xpert® MTB/RIF assay for pulmonary tuberculosis and rifampicin resistance in adults
title_sort xpert® mtb/rif assay for pulmonary tuberculosis and rifampicin resistance in adults
topic Medicine General & Introductory Medical Sciences
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4470349/
https://www.ncbi.nlm.nih.gov/pubmed/24448973
http://dx.doi.org/10.1002/14651858.CD009593.pub3
work_keys_str_mv AT steingartkarenr xpertmtbrifassayforpulmonarytuberculosisandrifampicinresistanceinadults
AT schillerian xpertmtbrifassayforpulmonarytuberculosisandrifampicinresistanceinadults
AT hornedavidj xpertmtbrifassayforpulmonarytuberculosisandrifampicinresistanceinadults
AT paimadhukar xpertmtbrifassayforpulmonarytuberculosisandrifampicinresistanceinadults
AT boehmecatharinac xpertmtbrifassayforpulmonarytuberculosisandrifampicinresistanceinadults
AT dendukurinandini xpertmtbrifassayforpulmonarytuberculosisandrifampicinresistanceinadults