Radiation dose to patients from X-ray radiographic examinations using computed radiography imaging system
The screen-film system is replaced by computed radiography system for recording the images of the patients during X-ray radiography examinations. The change in imaging system requires the re-establishment of the institutional diagnostic reference levels (DRLs) for different types of X-ray examinatio...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4471642/ https://www.ncbi.nlm.nih.gov/pubmed/26150685 http://dx.doi.org/10.4103/0971-6203.152244 |
_version_ | 1782376946041094144 |
---|---|
author | Sharma, Reena Sharma, Sunil Dutt Pawar, Shramika Chaubey, Ajay Kantharia, S. Babu, D. A. R. |
author_facet | Sharma, Reena Sharma, Sunil Dutt Pawar, Shramika Chaubey, Ajay Kantharia, S. Babu, D. A. R. |
author_sort | Sharma, Reena |
collection | PubMed |
description | The screen-film system is replaced by computed radiography system for recording the images of the patients during X-ray radiography examinations. The change in imaging system requires the re-establishment of the institutional diagnostic reference levels (DRLs) for different types of X-ray examinations conducted at the hospital. For this purpose, patient specific parameters [age, height, weight, body mass index (BMI), object to image distance (OID)] and machine specific parameters (kVp, mAs, distance and field sizes) of 1875 patients during 21 different types of X-ray examinations were recorded for estimating the entrance skin dose (ESD). The ESD for each of these patients were estimated using measured X-ray beam output and the standard value of the back scatter factor. Five number summary was calculated for all the data for their presentation in the Box-Whisker plot, which provides the statistical distribution of the data. The data collected indicates that majorly performed examinations are cervical spine AP, Chest PA and Knee Lat with percentage contributions of 16.05, 16 and 8.27% respectively. The lowest contribution comes from Hip Lat which is about 1.01%. The ratio of measured ESD (maximum to minimum) for these examinations is found to be highest for the cervical spine AP with a value of 50 followed by Thoracic spine AP of 32.36. The ESD ratio for Chest PA, Knee Lat and Lumbar Spine AP are 30.75, 30.4 and 30.2 respectively. The lowest ESD ratio is for Hip Lat which is 2.68. The third quartile values of ESDs are established as the institutional DRLs. The ESD values obtained for 21 different X-ray projections are either comparable or lesser than the reported national/international values. |
format | Online Article Text |
id | pubmed-4471642 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-44716422015-07-06 Radiation dose to patients from X-ray radiographic examinations using computed radiography imaging system Sharma, Reena Sharma, Sunil Dutt Pawar, Shramika Chaubey, Ajay Kantharia, S. Babu, D. A. R. J Med Phys Original Article The screen-film system is replaced by computed radiography system for recording the images of the patients during X-ray radiography examinations. The change in imaging system requires the re-establishment of the institutional diagnostic reference levels (DRLs) for different types of X-ray examinations conducted at the hospital. For this purpose, patient specific parameters [age, height, weight, body mass index (BMI), object to image distance (OID)] and machine specific parameters (kVp, mAs, distance and field sizes) of 1875 patients during 21 different types of X-ray examinations were recorded for estimating the entrance skin dose (ESD). The ESD for each of these patients were estimated using measured X-ray beam output and the standard value of the back scatter factor. Five number summary was calculated for all the data for their presentation in the Box-Whisker plot, which provides the statistical distribution of the data. The data collected indicates that majorly performed examinations are cervical spine AP, Chest PA and Knee Lat with percentage contributions of 16.05, 16 and 8.27% respectively. The lowest contribution comes from Hip Lat which is about 1.01%. The ratio of measured ESD (maximum to minimum) for these examinations is found to be highest for the cervical spine AP with a value of 50 followed by Thoracic spine AP of 32.36. The ESD ratio for Chest PA, Knee Lat and Lumbar Spine AP are 30.75, 30.4 and 30.2 respectively. The lowest ESD ratio is for Hip Lat which is 2.68. The third quartile values of ESDs are established as the institutional DRLs. The ESD values obtained for 21 different X-ray projections are either comparable or lesser than the reported national/international values. Medknow Publications & Media Pvt Ltd 2015 /pmc/articles/PMC4471642/ /pubmed/26150685 http://dx.doi.org/10.4103/0971-6203.152244 Text en Copyright: © Journal of Medical Physics http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Sharma, Reena Sharma, Sunil Dutt Pawar, Shramika Chaubey, Ajay Kantharia, S. Babu, D. A. R. Radiation dose to patients from X-ray radiographic examinations using computed radiography imaging system |
title | Radiation dose to patients from X-ray radiographic examinations using computed radiography imaging system |
title_full | Radiation dose to patients from X-ray radiographic examinations using computed radiography imaging system |
title_fullStr | Radiation dose to patients from X-ray radiographic examinations using computed radiography imaging system |
title_full_unstemmed | Radiation dose to patients from X-ray radiographic examinations using computed radiography imaging system |
title_short | Radiation dose to patients from X-ray radiographic examinations using computed radiography imaging system |
title_sort | radiation dose to patients from x-ray radiographic examinations using computed radiography imaging system |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4471642/ https://www.ncbi.nlm.nih.gov/pubmed/26150685 http://dx.doi.org/10.4103/0971-6203.152244 |
work_keys_str_mv | AT sharmareena radiationdosetopatientsfromxrayradiographicexaminationsusingcomputedradiographyimagingsystem AT sharmasunildutt radiationdosetopatientsfromxrayradiographicexaminationsusingcomputedradiographyimagingsystem AT pawarshramika radiationdosetopatientsfromxrayradiographicexaminationsusingcomputedradiographyimagingsystem AT chaubeyajay radiationdosetopatientsfromxrayradiographicexaminationsusingcomputedradiographyimagingsystem AT kantharias radiationdosetopatientsfromxrayradiographicexaminationsusingcomputedradiographyimagingsystem AT babudar radiationdosetopatientsfromxrayradiographicexaminationsusingcomputedradiographyimagingsystem |