Cargando…

Pre-closure of Large-Sized Arterial Access Sites in Adults Undergoing Transcatheter Structural Interventions

INTRODUCTION: Patients undergoing structural heart interventions often require large-sized sheath insertion into femoral arteries and veins. Clinical outcome data on the use of suture-mediated devices for large femoral arterial access in structural heart interventions is limited. We assessed the eff...

Descripción completa

Detalles Bibliográficos
Autores principales: Hamid, Tahir, Choudhury, Tawfiq R., Clarke, Bernard, Mahadevan, Vaikom S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Healthcare 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4472648/
https://www.ncbi.nlm.nih.gov/pubmed/25534873
http://dx.doi.org/10.1007/s40119-014-0034-7
Descripción
Sumario:INTRODUCTION: Patients undergoing structural heart interventions often require large-sized sheath insertion into femoral arteries and veins. Clinical outcome data on the use of suture-mediated devices for large femoral arterial access in structural heart interventions is limited. We assessed the efficacy of the Perclose™ (Abbott Vascular Devices, Santa Clara, CA, USA) suture-mediated device using the pre-closure technique in achieving hemostasis in femoral arterial access sites following large sheath insertion (≥8 Fr). METHODS: One hundred consecutive patients underwent 101 femoral artery access sites closures with the Perclose device using the pre-closure technique. Sixty-two percent of the patients were male and their mean (SD) age was 52 (±26) years. All patients received heparin. RESULTS: Mean arterial access site sheath diameter was 13 ± 2 Fr. Immediate hemostasis was achieved in 96/101 (96%) procedures (≤2 min). Two patients (2%) had access site-related complications requiring further interventions. On clinical follow up [mean (SD) follow-up of 24 (±12) months and median follow-up of 8.5 months], no complications were seen in the arterial access sites. CONCLUSION: Pre-closure of large-size femoral arterial access sheath sites using the suture-mediated Perclose device is efficacious in achieving rapid hemostasis in patients undergoing structural interventions. On 1-year follow-up, there were no arterial access site complications requiring further investigations or interventions. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s40119-014-0034-7) contains supplementary material, which is available to authorized users.