Cargando…
Diagnostic accuracy of Magnetic Resonance Imaging in assessment of Meniscal and ACL tear: Correlation with arthroscopy
OBJECTIVE: To determine the diagnostic accuracy of magnetic resonance imaging (MRI) in injuries related to anterior cruciate ligament and menisci and compare its effectiveness with that of arthroscopy. METHODS: This retrospective cross-sectional study was conducted in the department of Radiology &am...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Professional Medical Publications
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4476323/ https://www.ncbi.nlm.nih.gov/pubmed/26101472 http://dx.doi.org/10.12669/pjms.312.6499 |
_version_ | 1782377582739587072 |
---|---|
author | Yaqoob, Jamal Alam, Muhammad Shahbaz Khalid, Nadeem |
author_facet | Yaqoob, Jamal Alam, Muhammad Shahbaz Khalid, Nadeem |
author_sort | Yaqoob, Jamal |
collection | PubMed |
description | OBJECTIVE: To determine the diagnostic accuracy of magnetic resonance imaging (MRI) in injuries related to anterior cruciate ligament and menisci and compare its effectiveness with that of arthroscopy. METHODS: This retrospective cross-sectional study was conducted in the department of Radiology & Medical Imaging of Dallah Hospital, Riyadh, Kingdom of Saudi Arabia from September 2012 to March 2014. Fifty four patients (including 30 men and 24 women) with internal derangement of knee referred from the orthopedic consulting clinics underwent MR imaging followed by arthroscopic evaluation. The presence of meniscal and ligamentous abnormality on the imaging was documented by two trained radiologist. Findings were later compared with arthroscopic findings. RESULTS: The sensitivity, specificity and accuracy of MR imaging for menisci and ACL injury were calculated: 100% sensitivity, 88.4% specificity, 90% positive predictive value, 100% negative predictive value, and 94.4% accuracy were noted for medial meniscal injury. Similarly, MR had sensitivity of 85.7%, specificity of 95%, positive predictive value of 85.7%, negative predictive value of 95%, and accuracy of 92.5% for lateral meniscal injuries. Likewise, anterior cruciate ligament had 91.6% sensitivity, 95.2% specificity, 84.6% positive predictive value, 97.5% negative predictive value, and 94.4% accuracy. CONCLUSION: MRI is extremely helpful in identifying meniscal and anterior cruciate ligaments tears. MR imaging has high negative predictive value making it better choice as screening tool compared to diagnostic arthroscopic evaluation in most patients with soft tissue trauma to knee. |
format | Online Article Text |
id | pubmed-4476323 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Professional Medical Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-44763232015-06-22 Diagnostic accuracy of Magnetic Resonance Imaging in assessment of Meniscal and ACL tear: Correlation with arthroscopy Yaqoob, Jamal Alam, Muhammad Shahbaz Khalid, Nadeem Pak J Med Sci Original Article OBJECTIVE: To determine the diagnostic accuracy of magnetic resonance imaging (MRI) in injuries related to anterior cruciate ligament and menisci and compare its effectiveness with that of arthroscopy. METHODS: This retrospective cross-sectional study was conducted in the department of Radiology & Medical Imaging of Dallah Hospital, Riyadh, Kingdom of Saudi Arabia from September 2012 to March 2014. Fifty four patients (including 30 men and 24 women) with internal derangement of knee referred from the orthopedic consulting clinics underwent MR imaging followed by arthroscopic evaluation. The presence of meniscal and ligamentous abnormality on the imaging was documented by two trained radiologist. Findings were later compared with arthroscopic findings. RESULTS: The sensitivity, specificity and accuracy of MR imaging for menisci and ACL injury were calculated: 100% sensitivity, 88.4% specificity, 90% positive predictive value, 100% negative predictive value, and 94.4% accuracy were noted for medial meniscal injury. Similarly, MR had sensitivity of 85.7%, specificity of 95%, positive predictive value of 85.7%, negative predictive value of 95%, and accuracy of 92.5% for lateral meniscal injuries. Likewise, anterior cruciate ligament had 91.6% sensitivity, 95.2% specificity, 84.6% positive predictive value, 97.5% negative predictive value, and 94.4% accuracy. CONCLUSION: MRI is extremely helpful in identifying meniscal and anterior cruciate ligaments tears. MR imaging has high negative predictive value making it better choice as screening tool compared to diagnostic arthroscopic evaluation in most patients with soft tissue trauma to knee. Professional Medical Publications 2015 /pmc/articles/PMC4476323/ /pubmed/26101472 http://dx.doi.org/10.12669/pjms.312.6499 Text en Copyright: © Pakistan Journal of Medical Sciences http://creativecommons.org/licenses/by/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Yaqoob, Jamal Alam, Muhammad Shahbaz Khalid, Nadeem Diagnostic accuracy of Magnetic Resonance Imaging in assessment of Meniscal and ACL tear: Correlation with arthroscopy |
title | Diagnostic accuracy of Magnetic Resonance Imaging in assessment of Meniscal and ACL tear: Correlation with arthroscopy |
title_full | Diagnostic accuracy of Magnetic Resonance Imaging in assessment of Meniscal and ACL tear: Correlation with arthroscopy |
title_fullStr | Diagnostic accuracy of Magnetic Resonance Imaging in assessment of Meniscal and ACL tear: Correlation with arthroscopy |
title_full_unstemmed | Diagnostic accuracy of Magnetic Resonance Imaging in assessment of Meniscal and ACL tear: Correlation with arthroscopy |
title_short | Diagnostic accuracy of Magnetic Resonance Imaging in assessment of Meniscal and ACL tear: Correlation with arthroscopy |
title_sort | diagnostic accuracy of magnetic resonance imaging in assessment of meniscal and acl tear: correlation with arthroscopy |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4476323/ https://www.ncbi.nlm.nih.gov/pubmed/26101472 http://dx.doi.org/10.12669/pjms.312.6499 |
work_keys_str_mv | AT yaqoobjamal diagnosticaccuracyofmagneticresonanceimaginginassessmentofmeniscalandacltearcorrelationwitharthroscopy AT alammuhammadshahbaz diagnosticaccuracyofmagneticresonanceimaginginassessmentofmeniscalandacltearcorrelationwitharthroscopy AT khalidnadeem diagnosticaccuracyofmagneticresonanceimaginginassessmentofmeniscalandacltearcorrelationwitharthroscopy |