Cargando…

Diagnostic accuracy of Magnetic Resonance Imaging in assessment of Meniscal and ACL tear: Correlation with arthroscopy

OBJECTIVE: To determine the diagnostic accuracy of magnetic resonance imaging (MRI) in injuries related to anterior cruciate ligament and menisci and compare its effectiveness with that of arthroscopy. METHODS: This retrospective cross-sectional study was conducted in the department of Radiology &am...

Descripción completa

Detalles Bibliográficos
Autores principales: Yaqoob, Jamal, Alam, Muhammad Shahbaz, Khalid, Nadeem
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Professional Medical Publications 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4476323/
https://www.ncbi.nlm.nih.gov/pubmed/26101472
http://dx.doi.org/10.12669/pjms.312.6499
_version_ 1782377582739587072
author Yaqoob, Jamal
Alam, Muhammad Shahbaz
Khalid, Nadeem
author_facet Yaqoob, Jamal
Alam, Muhammad Shahbaz
Khalid, Nadeem
author_sort Yaqoob, Jamal
collection PubMed
description OBJECTIVE: To determine the diagnostic accuracy of magnetic resonance imaging (MRI) in injuries related to anterior cruciate ligament and menisci and compare its effectiveness with that of arthroscopy. METHODS: This retrospective cross-sectional study was conducted in the department of Radiology & Medical Imaging of Dallah Hospital, Riyadh, Kingdom of Saudi Arabia from September 2012 to March 2014. Fifty four patients (including 30 men and 24 women) with internal derangement of knee referred from the orthopedic consulting clinics underwent MR imaging followed by arthroscopic evaluation. The presence of meniscal and ligamentous abnormality on the imaging was documented by two trained radiologist. Findings were later compared with arthroscopic findings. RESULTS: The sensitivity, specificity and accuracy of MR imaging for menisci and ACL injury were calculated: 100% sensitivity, 88.4% specificity, 90% positive predictive value, 100% negative predictive value, and 94.4% accuracy were noted for medial meniscal injury. Similarly, MR had sensitivity of 85.7%, specificity of 95%, positive predictive value of 85.7%, negative predictive value of 95%, and accuracy of 92.5% for lateral meniscal injuries. Likewise, anterior cruciate ligament had 91.6% sensitivity, 95.2% specificity, 84.6% positive predictive value, 97.5% negative predictive value, and 94.4% accuracy. CONCLUSION: MRI is extremely helpful in identifying meniscal and anterior cruciate ligaments tears. MR imaging has high negative predictive value making it better choice as screening tool compared to diagnostic arthroscopic evaluation in most patients with soft tissue trauma to knee.
format Online
Article
Text
id pubmed-4476323
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Professional Medical Publications
record_format MEDLINE/PubMed
spelling pubmed-44763232015-06-22 Diagnostic accuracy of Magnetic Resonance Imaging in assessment of Meniscal and ACL tear: Correlation with arthroscopy Yaqoob, Jamal Alam, Muhammad Shahbaz Khalid, Nadeem Pak J Med Sci Original Article OBJECTIVE: To determine the diagnostic accuracy of magnetic resonance imaging (MRI) in injuries related to anterior cruciate ligament and menisci and compare its effectiveness with that of arthroscopy. METHODS: This retrospective cross-sectional study was conducted in the department of Radiology & Medical Imaging of Dallah Hospital, Riyadh, Kingdom of Saudi Arabia from September 2012 to March 2014. Fifty four patients (including 30 men and 24 women) with internal derangement of knee referred from the orthopedic consulting clinics underwent MR imaging followed by arthroscopic evaluation. The presence of meniscal and ligamentous abnormality on the imaging was documented by two trained radiologist. Findings were later compared with arthroscopic findings. RESULTS: The sensitivity, specificity and accuracy of MR imaging for menisci and ACL injury were calculated: 100% sensitivity, 88.4% specificity, 90% positive predictive value, 100% negative predictive value, and 94.4% accuracy were noted for medial meniscal injury. Similarly, MR had sensitivity of 85.7%, specificity of 95%, positive predictive value of 85.7%, negative predictive value of 95%, and accuracy of 92.5% for lateral meniscal injuries. Likewise, anterior cruciate ligament had 91.6% sensitivity, 95.2% specificity, 84.6% positive predictive value, 97.5% negative predictive value, and 94.4% accuracy. CONCLUSION: MRI is extremely helpful in identifying meniscal and anterior cruciate ligaments tears. MR imaging has high negative predictive value making it better choice as screening tool compared to diagnostic arthroscopic evaluation in most patients with soft tissue trauma to knee. Professional Medical Publications 2015 /pmc/articles/PMC4476323/ /pubmed/26101472 http://dx.doi.org/10.12669/pjms.312.6499 Text en Copyright: © Pakistan Journal of Medical Sciences http://creativecommons.org/licenses/by/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Yaqoob, Jamal
Alam, Muhammad Shahbaz
Khalid, Nadeem
Diagnostic accuracy of Magnetic Resonance Imaging in assessment of Meniscal and ACL tear: Correlation with arthroscopy
title Diagnostic accuracy of Magnetic Resonance Imaging in assessment of Meniscal and ACL tear: Correlation with arthroscopy
title_full Diagnostic accuracy of Magnetic Resonance Imaging in assessment of Meniscal and ACL tear: Correlation with arthroscopy
title_fullStr Diagnostic accuracy of Magnetic Resonance Imaging in assessment of Meniscal and ACL tear: Correlation with arthroscopy
title_full_unstemmed Diagnostic accuracy of Magnetic Resonance Imaging in assessment of Meniscal and ACL tear: Correlation with arthroscopy
title_short Diagnostic accuracy of Magnetic Resonance Imaging in assessment of Meniscal and ACL tear: Correlation with arthroscopy
title_sort diagnostic accuracy of magnetic resonance imaging in assessment of meniscal and acl tear: correlation with arthroscopy
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4476323/
https://www.ncbi.nlm.nih.gov/pubmed/26101472
http://dx.doi.org/10.12669/pjms.312.6499
work_keys_str_mv AT yaqoobjamal diagnosticaccuracyofmagneticresonanceimaginginassessmentofmeniscalandacltearcorrelationwitharthroscopy
AT alammuhammadshahbaz diagnosticaccuracyofmagneticresonanceimaginginassessmentofmeniscalandacltearcorrelationwitharthroscopy
AT khalidnadeem diagnosticaccuracyofmagneticresonanceimaginginassessmentofmeniscalandacltearcorrelationwitharthroscopy