Cargando…

64Cu-ATSM Hypoxia Positron Emission Tomography for Detection of Conduit Ischemia in an Experimental Rat Esophagectomy Model

BACKGROUND: We designed a hypoxia-imaging modality to detect ischemia of the gastric conduit after esophagectomy. MATERIALS AND METHODS: A rat esophagectomy model was created using 12-16-week-old, 300-350 g male Sprague-Dawley rats. In the operation group (n=6), partial gastric devascularization was...

Descripción completa

Detalles Bibliográficos
Autores principales: Park, Seong Yong, Kang, Won Jun, Cho, Arthur, Chae, Ju Ri, Cho, Ye Lim, Kim, Jung Young, Lee, Ji Woong, Chung, Kyung Young
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4476727/
https://www.ncbi.nlm.nih.gov/pubmed/26098420
http://dx.doi.org/10.1371/journal.pone.0131083
_version_ 1782377643022221312
author Park, Seong Yong
Kang, Won Jun
Cho, Arthur
Chae, Ju Ri
Cho, Ye Lim
Kim, Jung Young
Lee, Ji Woong
Chung, Kyung Young
author_facet Park, Seong Yong
Kang, Won Jun
Cho, Arthur
Chae, Ju Ri
Cho, Ye Lim
Kim, Jung Young
Lee, Ji Woong
Chung, Kyung Young
author_sort Park, Seong Yong
collection PubMed
description BACKGROUND: We designed a hypoxia-imaging modality to detect ischemia of the gastric conduit after esophagectomy. MATERIALS AND METHODS: A rat esophagectomy model was created using 12-16-week-old, 300-350 g male Sprague-Dawley rats. In the operation group (n=6), partial gastric devascularization was performed by ligating the left gastric artery and the short gastric arteries and an esophagogastric anastomosis was performed. In the control group (n=6), the esophageal-gastric junction was incised and suturing was performed without gastric devascularization. Positron emission tomography (PET) images were taken using a microPET rodent model scanner, 24 h after the initial operation, after injection of 200 μCi 64Cu-diacetyl-bis (N4-methylsemicarbazone) (64Cu-ATSM) and pimonidazole 120 mg/kg. After microPET imaging, autoradiography and immunohistochemistry were performed. RESULTS: The PET image revealed 64Cu-ATSM uptake at the fundus in the operation group 3 h after 64Cu-ATSM injection. The maximum percentage of the injected dose per gram of tissue was higher in the operation group (0.047±0.015 vs. 0.026±0.006, p=0.021). The fundus/liver ratio was also higher in the operation group (0.541±0.126 vs. 0.278±0.049, p=0.002). Upon autoradiography, 64Cu-ATSM uptake was observed in the fundus in the operation group, and was well-correlated to that observed on the PET image. Upon immunohistochemistry, expression of hypoxia-inducible factor 1a and pimonidazole were significantly increased at the fundus and lesser curvature compared to the greater curvature in the operation group. CONCLUSION: Hypoxia PET imaging with 64Cu-ATSM can detect ischemia in a rat esophagectomy model. Further clinical studies are needed to verify whether hypoxia imaging may be useful in humans.
format Online
Article
Text
id pubmed-4476727
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-44767272015-06-25 64Cu-ATSM Hypoxia Positron Emission Tomography for Detection of Conduit Ischemia in an Experimental Rat Esophagectomy Model Park, Seong Yong Kang, Won Jun Cho, Arthur Chae, Ju Ri Cho, Ye Lim Kim, Jung Young Lee, Ji Woong Chung, Kyung Young PLoS One Research Article BACKGROUND: We designed a hypoxia-imaging modality to detect ischemia of the gastric conduit after esophagectomy. MATERIALS AND METHODS: A rat esophagectomy model was created using 12-16-week-old, 300-350 g male Sprague-Dawley rats. In the operation group (n=6), partial gastric devascularization was performed by ligating the left gastric artery and the short gastric arteries and an esophagogastric anastomosis was performed. In the control group (n=6), the esophageal-gastric junction was incised and suturing was performed without gastric devascularization. Positron emission tomography (PET) images were taken using a microPET rodent model scanner, 24 h after the initial operation, after injection of 200 μCi 64Cu-diacetyl-bis (N4-methylsemicarbazone) (64Cu-ATSM) and pimonidazole 120 mg/kg. After microPET imaging, autoradiography and immunohistochemistry were performed. RESULTS: The PET image revealed 64Cu-ATSM uptake at the fundus in the operation group 3 h after 64Cu-ATSM injection. The maximum percentage of the injected dose per gram of tissue was higher in the operation group (0.047±0.015 vs. 0.026±0.006, p=0.021). The fundus/liver ratio was also higher in the operation group (0.541±0.126 vs. 0.278±0.049, p=0.002). Upon autoradiography, 64Cu-ATSM uptake was observed in the fundus in the operation group, and was well-correlated to that observed on the PET image. Upon immunohistochemistry, expression of hypoxia-inducible factor 1a and pimonidazole were significantly increased at the fundus and lesser curvature compared to the greater curvature in the operation group. CONCLUSION: Hypoxia PET imaging with 64Cu-ATSM can detect ischemia in a rat esophagectomy model. Further clinical studies are needed to verify whether hypoxia imaging may be useful in humans. Public Library of Science 2015-06-22 /pmc/articles/PMC4476727/ /pubmed/26098420 http://dx.doi.org/10.1371/journal.pone.0131083 Text en © 2015 Park et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Park, Seong Yong
Kang, Won Jun
Cho, Arthur
Chae, Ju Ri
Cho, Ye Lim
Kim, Jung Young
Lee, Ji Woong
Chung, Kyung Young
64Cu-ATSM Hypoxia Positron Emission Tomography for Detection of Conduit Ischemia in an Experimental Rat Esophagectomy Model
title 64Cu-ATSM Hypoxia Positron Emission Tomography for Detection of Conduit Ischemia in an Experimental Rat Esophagectomy Model
title_full 64Cu-ATSM Hypoxia Positron Emission Tomography for Detection of Conduit Ischemia in an Experimental Rat Esophagectomy Model
title_fullStr 64Cu-ATSM Hypoxia Positron Emission Tomography for Detection of Conduit Ischemia in an Experimental Rat Esophagectomy Model
title_full_unstemmed 64Cu-ATSM Hypoxia Positron Emission Tomography for Detection of Conduit Ischemia in an Experimental Rat Esophagectomy Model
title_short 64Cu-ATSM Hypoxia Positron Emission Tomography for Detection of Conduit Ischemia in an Experimental Rat Esophagectomy Model
title_sort 64cu-atsm hypoxia positron emission tomography for detection of conduit ischemia in an experimental rat esophagectomy model
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4476727/
https://www.ncbi.nlm.nih.gov/pubmed/26098420
http://dx.doi.org/10.1371/journal.pone.0131083
work_keys_str_mv AT parkseongyong 64cuatsmhypoxiapositronemissiontomographyfordetectionofconduitischemiainanexperimentalratesophagectomymodel
AT kangwonjun 64cuatsmhypoxiapositronemissiontomographyfordetectionofconduitischemiainanexperimentalratesophagectomymodel
AT choarthur 64cuatsmhypoxiapositronemissiontomographyfordetectionofconduitischemiainanexperimentalratesophagectomymodel
AT chaejuri 64cuatsmhypoxiapositronemissiontomographyfordetectionofconduitischemiainanexperimentalratesophagectomymodel
AT choyelim 64cuatsmhypoxiapositronemissiontomographyfordetectionofconduitischemiainanexperimentalratesophagectomymodel
AT kimjungyoung 64cuatsmhypoxiapositronemissiontomographyfordetectionofconduitischemiainanexperimentalratesophagectomymodel
AT leejiwoong 64cuatsmhypoxiapositronemissiontomographyfordetectionofconduitischemiainanexperimentalratesophagectomymodel
AT chungkyungyoung 64cuatsmhypoxiapositronemissiontomographyfordetectionofconduitischemiainanexperimentalratesophagectomymodel