Microbiological Assessment of Indoor Air of Teaching Hospital Wards: A case of Jimma University Specialized Hospital

BACKGROUND: Hospital environment represents a congenial situation where microorganisms and susceptible patients are indoors together. Thus, the objective of this study is to provide fundamental data related to the microbial quality of indoor air of Jimma University Specialized Hospital wards, to est...

Descripción completa

Detalles Bibliográficos
Autores principales: Fekadu, Samuel, Getachewu, Bahilu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Research and Publications Office of Jimma University 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4478262/
https://www.ncbi.nlm.nih.gov/pubmed/26124618
_version_ 1782377858982739968
author Fekadu, Samuel
Getachewu, Bahilu
author_facet Fekadu, Samuel
Getachewu, Bahilu
author_sort Fekadu, Samuel
collection PubMed
description BACKGROUND: Hospital environment represents a congenial situation where microorganisms and susceptible patients are indoors together. Thus, the objective of this study is to provide fundamental data related to the microbial quality of indoor air of Jimma University Specialized Hospital wards, to estimate the health hazard and to create standards for indoor air quality control. METHODS: The microbial quality of indoor air of seven wards of Jimma University Specialized Hospital was determined. Passive air sampling technique, using open Petri-dishes containing different culture media, was employed to collect sample twice daily. RESULTS: The concentrations of bacteria and fungi aerosols in the indoor environment of the wards ranged between 2123 – 9733 CFU/m(3). The statistical analysis showed that the concentrations of bacteria that were measured in all studied wards were significantly different from each other (p-value=0.017), whereas the concentrations of fungi that were measured in all sampled wards were not significantly different from each other (p-value=0.850). Moreover, the concentrations of bacteria that were measured at different sampling time (morning and afternoon) were significantly different (p-value =0.001). CONCLUSION: All wards that were included in the study were heavily contaminated with bacteria and fungi. Thus, immediate interventions are needed to control those environmental factors which favor the growth and multiplication of microbes, and it is vital to control visitors and students in and out the wards. Moreover, it is advisable that strict measures be put in place to check the increasing microbial load in the hospital environment.
format Online
Article
Text
id pubmed-4478262
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Research and Publications Office of Jimma University
record_format MEDLINE/PubMed
spelling pubmed-44782622015-06-29 Microbiological Assessment of Indoor Air of Teaching Hospital Wards: A case of Jimma University Specialized Hospital Fekadu, Samuel Getachewu, Bahilu Ethiop J Health Sci Original Article BACKGROUND: Hospital environment represents a congenial situation where microorganisms and susceptible patients are indoors together. Thus, the objective of this study is to provide fundamental data related to the microbial quality of indoor air of Jimma University Specialized Hospital wards, to estimate the health hazard and to create standards for indoor air quality control. METHODS: The microbial quality of indoor air of seven wards of Jimma University Specialized Hospital was determined. Passive air sampling technique, using open Petri-dishes containing different culture media, was employed to collect sample twice daily. RESULTS: The concentrations of bacteria and fungi aerosols in the indoor environment of the wards ranged between 2123 – 9733 CFU/m(3). The statistical analysis showed that the concentrations of bacteria that were measured in all studied wards were significantly different from each other (p-value=0.017), whereas the concentrations of fungi that were measured in all sampled wards were not significantly different from each other (p-value=0.850). Moreover, the concentrations of bacteria that were measured at different sampling time (morning and afternoon) were significantly different (p-value =0.001). CONCLUSION: All wards that were included in the study were heavily contaminated with bacteria and fungi. Thus, immediate interventions are needed to control those environmental factors which favor the growth and multiplication of microbes, and it is vital to control visitors and students in and out the wards. Moreover, it is advisable that strict measures be put in place to check the increasing microbial load in the hospital environment. Research and Publications Office of Jimma University 2015-04 /pmc/articles/PMC4478262/ /pubmed/26124618 Text en Copyright © Jimma University, Research & Publications Office 2015
spellingShingle Original Article
Fekadu, Samuel
Getachewu, Bahilu
Microbiological Assessment of Indoor Air of Teaching Hospital Wards: A case of Jimma University Specialized Hospital
title Microbiological Assessment of Indoor Air of Teaching Hospital Wards: A case of Jimma University Specialized Hospital
title_full Microbiological Assessment of Indoor Air of Teaching Hospital Wards: A case of Jimma University Specialized Hospital
title_fullStr Microbiological Assessment of Indoor Air of Teaching Hospital Wards: A case of Jimma University Specialized Hospital
title_full_unstemmed Microbiological Assessment of Indoor Air of Teaching Hospital Wards: A case of Jimma University Specialized Hospital
title_short Microbiological Assessment of Indoor Air of Teaching Hospital Wards: A case of Jimma University Specialized Hospital
title_sort microbiological assessment of indoor air of teaching hospital wards: a case of jimma university specialized hospital
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4478262/
https://www.ncbi.nlm.nih.gov/pubmed/26124618
work_keys_str_mv AT fekadusamuel microbiologicalassessmentofindoorairofteachinghospitalwardsacaseofjimmauniversityspecializedhospital
AT getachewubahilu microbiologicalassessmentofindoorairofteachinghospitalwardsacaseofjimmauniversityspecializedhospital