Cargando…
Small fields measurements with radiochromic films
The small fields in radiotherapy are widely used due to the development of techniques such as intensity-modulated radiotherapy and stereotactic radio surgery. The measurement of the dose distributions for small fields is a challenge. A perfect dosimeter should be independent of the radiation energy...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4478646/ https://www.ncbi.nlm.nih.gov/pubmed/26170551 http://dx.doi.org/10.4103/0971-6203.158667 |
_version_ | 1782377917645324288 |
---|---|
author | Gonzalez-Lopez, Antonio Vera-Sanchez, Juan-Antonio Lago-Martin, Jose-Domingo |
author_facet | Gonzalez-Lopez, Antonio Vera-Sanchez, Juan-Antonio Lago-Martin, Jose-Domingo |
author_sort | Gonzalez-Lopez, Antonio |
collection | PubMed |
description | The small fields in radiotherapy are widely used due to the development of techniques such as intensity-modulated radiotherapy and stereotactic radio surgery. The measurement of the dose distributions for small fields is a challenge. A perfect dosimeter should be independent of the radiation energy and the dose rate and should have a negligible volume effect. The radiochromic (RC) film characteristics fit well to these requirements. However, the response of RC films and their digitizing processes present a significant spatial inhomogeneity problem. The present work uses a method for two-dimensional (2D) measurement with RC films based on the reduction of the spatial inhomogeneity of both the film and the film digitizing process. By means of registering and averaging several measurements of the same field, the inhomogeneities are mostly canceled. Measurements of output factors (OFs), dose profiles (in-plane and cross-plane), and 2D dose distributions are presented. The field sizes investigated are 0.5 × 0.5 cm(2), 0.7 × 0.7 cm(2), 1 × 1 cm(2), 2 × 2 cm(2), 3 × 3 cm(2), 6 × 6 cm(2), and 10 × 10 cm(2) for 6 and 15 MV photon beams. The OFs measured with the RC film are compared with the measurements carried out with a PinPoint ionization chamber (IC) and a Semiflex IC, while the measured transversal dose profiles were compared with Monte Carlo simulations. The results obtained for the OFs measurements show a good agreement with the values obtained from RC films and the PinPoint and Semiflex chambers when the field size is greater or equal than 2 × 2 cm(2). These agreements give confidence on the accuracy of the method as well as on the results obtained for smaller fields. Also, good agreement was found between the measured profiles and the Monte Carlo calculated profiles for the field size of 1 × 1 cm(2). We expect, therefore, that the presented method can be used to perform accurate measurements of small fields. |
format | Online Article Text |
id | pubmed-4478646 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-44786462015-07-13 Small fields measurements with radiochromic films Gonzalez-Lopez, Antonio Vera-Sanchez, Juan-Antonio Lago-Martin, Jose-Domingo J Med Phys Original Article The small fields in radiotherapy are widely used due to the development of techniques such as intensity-modulated radiotherapy and stereotactic radio surgery. The measurement of the dose distributions for small fields is a challenge. A perfect dosimeter should be independent of the radiation energy and the dose rate and should have a negligible volume effect. The radiochromic (RC) film characteristics fit well to these requirements. However, the response of RC films and their digitizing processes present a significant spatial inhomogeneity problem. The present work uses a method for two-dimensional (2D) measurement with RC films based on the reduction of the spatial inhomogeneity of both the film and the film digitizing process. By means of registering and averaging several measurements of the same field, the inhomogeneities are mostly canceled. Measurements of output factors (OFs), dose profiles (in-plane and cross-plane), and 2D dose distributions are presented. The field sizes investigated are 0.5 × 0.5 cm(2), 0.7 × 0.7 cm(2), 1 × 1 cm(2), 2 × 2 cm(2), 3 × 3 cm(2), 6 × 6 cm(2), and 10 × 10 cm(2) for 6 and 15 MV photon beams. The OFs measured with the RC film are compared with the measurements carried out with a PinPoint ionization chamber (IC) and a Semiflex IC, while the measured transversal dose profiles were compared with Monte Carlo simulations. The results obtained for the OFs measurements show a good agreement with the values obtained from RC films and the PinPoint and Semiflex chambers when the field size is greater or equal than 2 × 2 cm(2). These agreements give confidence on the accuracy of the method as well as on the results obtained for smaller fields. Also, good agreement was found between the measured profiles and the Monte Carlo calculated profiles for the field size of 1 × 1 cm(2). We expect, therefore, that the presented method can be used to perform accurate measurements of small fields. Medknow Publications & Media Pvt Ltd 2015 /pmc/articles/PMC4478646/ /pubmed/26170551 http://dx.doi.org/10.4103/0971-6203.158667 Text en Copyright: © Journal of Medical Physics http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Gonzalez-Lopez, Antonio Vera-Sanchez, Juan-Antonio Lago-Martin, Jose-Domingo Small fields measurements with radiochromic films |
title | Small fields measurements with radiochromic films |
title_full | Small fields measurements with radiochromic films |
title_fullStr | Small fields measurements with radiochromic films |
title_full_unstemmed | Small fields measurements with radiochromic films |
title_short | Small fields measurements with radiochromic films |
title_sort | small fields measurements with radiochromic films |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4478646/ https://www.ncbi.nlm.nih.gov/pubmed/26170551 http://dx.doi.org/10.4103/0971-6203.158667 |
work_keys_str_mv | AT gonzalezlopezantonio smallfieldsmeasurementswithradiochromicfilms AT verasanchezjuanantonio smallfieldsmeasurementswithradiochromicfilms AT lagomartinjosedomingo smallfieldsmeasurementswithradiochromicfilms |