Cargando…
Noninvasive intracranial pressure monitoring via optic nerve sheath diameter for robotic surgery in steep Trendelenburg position
BACKGROUND: Recent reports of increased intracranial pressure (ICP) due to steep Trendelenburg (ST) position causing neurological deterioration, decreased regional cerebral oxygen saturation and postoperative visual loss after robotic urological and gynecological surgeries led us to consider a simpl...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4478813/ https://www.ncbi.nlm.nih.gov/pubmed/26240539 http://dx.doi.org/10.4103/1658-354X.154693 |
_version_ | 1782377937718214656 |
---|---|
author | Shah, Shagun Bhatia Bhargava, Ajay Kumar Choudhury, Itee |
author_facet | Shah, Shagun Bhatia Bhargava, Ajay Kumar Choudhury, Itee |
author_sort | Shah, Shagun Bhatia |
collection | PubMed |
description | BACKGROUND: Recent reports of increased intracranial pressure (ICP) due to steep Trendelenburg (ST) position causing neurological deterioration, decreased regional cerebral oxygen saturation and postoperative visual loss after robotic urological and gynecological surgeries led us to consider a simple technique of ICP monitoring. Ours is one of the first instances reported of quantitative noninvasive measurement of increase in ICP with ST position by serial measurement of binocular optic nerve sheath diameter (ONSD) in patients undergoing robot assisted urological and gynecological oncosurgery. We tested whether ONSD values rose to above the upper limits of normal and for what length of time they remained elevated. MATERIALS AND METHODS: Prospective, randomized, interventional, parallel group, active control study conducted on 252 American Society of Anesthesiologists I and II patients. ONSD was measured using 7.5 MHz linear ultrasound probe in supine and Trendelenburg positions. STATISTICS: Student's t-test to compare the inter-group mean ONSD and the repetitive t-test for intra-group analysis. RESULT: Comparison of the mean ONSD values of both groups yielded a 2-tailed significance P <0.01 at all compared time points intra- and post-operatively. In Group-O (open surgery; supine position), the baseline mean bilateral ONSD was 4.36 mm, which did not show any statistically significant change throughout open surgery and postoperative period. On de-docking the robot, 6.2 mm was the mean ONSD value in Group-R (robotic group) while 4.3 mm was the corresponding value in control Group-O. CONCLUSION: ONSD evaluation is a simple, quick, safe, readily available, reliable, cost effective, noninvasive, potential standard of care for screening and monitoring of patients undergoing robotic surgery in ST position. |
format | Online Article Text |
id | pubmed-4478813 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-44788132015-08-03 Noninvasive intracranial pressure monitoring via optic nerve sheath diameter for robotic surgery in steep Trendelenburg position Shah, Shagun Bhatia Bhargava, Ajay Kumar Choudhury, Itee Saudi J Anaesth Original Article BACKGROUND: Recent reports of increased intracranial pressure (ICP) due to steep Trendelenburg (ST) position causing neurological deterioration, decreased regional cerebral oxygen saturation and postoperative visual loss after robotic urological and gynecological surgeries led us to consider a simple technique of ICP monitoring. Ours is one of the first instances reported of quantitative noninvasive measurement of increase in ICP with ST position by serial measurement of binocular optic nerve sheath diameter (ONSD) in patients undergoing robot assisted urological and gynecological oncosurgery. We tested whether ONSD values rose to above the upper limits of normal and for what length of time they remained elevated. MATERIALS AND METHODS: Prospective, randomized, interventional, parallel group, active control study conducted on 252 American Society of Anesthesiologists I and II patients. ONSD was measured using 7.5 MHz linear ultrasound probe in supine and Trendelenburg positions. STATISTICS: Student's t-test to compare the inter-group mean ONSD and the repetitive t-test for intra-group analysis. RESULT: Comparison of the mean ONSD values of both groups yielded a 2-tailed significance P <0.01 at all compared time points intra- and post-operatively. In Group-O (open surgery; supine position), the baseline mean bilateral ONSD was 4.36 mm, which did not show any statistically significant change throughout open surgery and postoperative period. On de-docking the robot, 6.2 mm was the mean ONSD value in Group-R (robotic group) while 4.3 mm was the corresponding value in control Group-O. CONCLUSION: ONSD evaluation is a simple, quick, safe, readily available, reliable, cost effective, noninvasive, potential standard of care for screening and monitoring of patients undergoing robotic surgery in ST position. Medknow Publications & Media Pvt Ltd 2015 /pmc/articles/PMC4478813/ /pubmed/26240539 http://dx.doi.org/10.4103/1658-354X.154693 Text en Copyright: © Saudi Journal of Anaesthesia http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Shah, Shagun Bhatia Bhargava, Ajay Kumar Choudhury, Itee Noninvasive intracranial pressure monitoring via optic nerve sheath diameter for robotic surgery in steep Trendelenburg position |
title | Noninvasive intracranial pressure monitoring via optic nerve sheath diameter for robotic surgery in steep Trendelenburg position |
title_full | Noninvasive intracranial pressure monitoring via optic nerve sheath diameter for robotic surgery in steep Trendelenburg position |
title_fullStr | Noninvasive intracranial pressure monitoring via optic nerve sheath diameter for robotic surgery in steep Trendelenburg position |
title_full_unstemmed | Noninvasive intracranial pressure monitoring via optic nerve sheath diameter for robotic surgery in steep Trendelenburg position |
title_short | Noninvasive intracranial pressure monitoring via optic nerve sheath diameter for robotic surgery in steep Trendelenburg position |
title_sort | noninvasive intracranial pressure monitoring via optic nerve sheath diameter for robotic surgery in steep trendelenburg position |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4478813/ https://www.ncbi.nlm.nih.gov/pubmed/26240539 http://dx.doi.org/10.4103/1658-354X.154693 |
work_keys_str_mv | AT shahshagunbhatia noninvasiveintracranialpressuremonitoringviaopticnervesheathdiameterforroboticsurgeryinsteeptrendelenburgposition AT bhargavaajaykumar noninvasiveintracranialpressuremonitoringviaopticnervesheathdiameterforroboticsurgeryinsteeptrendelenburgposition AT choudhuryitee noninvasiveintracranialpressuremonitoringviaopticnervesheathdiameterforroboticsurgeryinsteeptrendelenburgposition |