Improvement of Accuracy in Environmental Dosimetry by TLD Cards Using Three-dimensional Calibration Method

INTRODUCTION: The angular dependency of response for TLD cards may cause deviation from its true value on the results of environmental dosimetry, since TLDs may be exposed to radiation at different angles of incidence from the surrounding area. OBJECTIVE: A 3D setting of TLD cards has been calibrate...

Descripción completa

Detalles Bibliográficos
Autores principales: HosseiniAliabadi, S. J., Hosseini Pooya, S. M., Afarideh, H., Mianji, F.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Shiraz University of Medical Sciences 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4479385/
https://www.ncbi.nlm.nih.gov/pubmed/26157729
_version_ 1782378001688690688
author HosseiniAliabadi, S. J.
Hosseini Pooya, S. M.
Afarideh, H.
Mianji, F.
author_facet HosseiniAliabadi, S. J.
Hosseini Pooya, S. M.
Afarideh, H.
Mianji, F.
author_sort HosseiniAliabadi, S. J.
collection PubMed
description INTRODUCTION: The angular dependency of response for TLD cards may cause deviation from its true value on the results of environmental dosimetry, since TLDs may be exposed to radiation at different angles of incidence from the surrounding area. OBJECTIVE: A 3D setting of TLD cards has been calibrated isotropically in a standard radiation field to evaluate the improvement of the accuracy of measurement for environmental dosimetry. METHOD: Three personal TLD cards were rectangularly placed in a cylindrical holder, and calibrated using 1D and 3D calibration methods. Then, the dosimeter has been used simultaneously with a reference instrument in a real radiation field measuring the accumulated dose within a time interval. RESULT: The results show that the accuracy of measurement has been improved by 6.5% using 3D calibration factor in comparison with that of normal 1D calibration method. CONCLUSION: This system can be utilized in large scale environmental monitoring with a higher accuracy.
format Online
Article
Text
id pubmed-4479385
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Shiraz University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-44793852015-07-08 Improvement of Accuracy in Environmental Dosimetry by TLD Cards Using Three-dimensional Calibration Method HosseiniAliabadi, S. J. Hosseini Pooya, S. M. Afarideh, H. Mianji, F. J Biomed Phys Eng Original Article INTRODUCTION: The angular dependency of response for TLD cards may cause deviation from its true value on the results of environmental dosimetry, since TLDs may be exposed to radiation at different angles of incidence from the surrounding area. OBJECTIVE: A 3D setting of TLD cards has been calibrated isotropically in a standard radiation field to evaluate the improvement of the accuracy of measurement for environmental dosimetry. METHOD: Three personal TLD cards were rectangularly placed in a cylindrical holder, and calibrated using 1D and 3D calibration methods. Then, the dosimeter has been used simultaneously with a reference instrument in a real radiation field measuring the accumulated dose within a time interval. RESULT: The results show that the accuracy of measurement has been improved by 6.5% using 3D calibration factor in comparison with that of normal 1D calibration method. CONCLUSION: This system can be utilized in large scale environmental monitoring with a higher accuracy. Shiraz University of Medical Sciences 2015-06-01 /pmc/articles/PMC4479385/ /pubmed/26157729 Text en © 2015: Journal of Biomedical Physics and Engineering This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial 3.0 Unported License (http://creativecommons.org/licenses/by/3.0/), which permits unrestricted use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
HosseiniAliabadi, S. J.
Hosseini Pooya, S. M.
Afarideh, H.
Mianji, F.
Improvement of Accuracy in Environmental Dosimetry by TLD Cards Using Three-dimensional Calibration Method
title Improvement of Accuracy in Environmental Dosimetry by TLD Cards Using Three-dimensional Calibration Method
title_full Improvement of Accuracy in Environmental Dosimetry by TLD Cards Using Three-dimensional Calibration Method
title_fullStr Improvement of Accuracy in Environmental Dosimetry by TLD Cards Using Three-dimensional Calibration Method
title_full_unstemmed Improvement of Accuracy in Environmental Dosimetry by TLD Cards Using Three-dimensional Calibration Method
title_short Improvement of Accuracy in Environmental Dosimetry by TLD Cards Using Three-dimensional Calibration Method
title_sort improvement of accuracy in environmental dosimetry by tld cards using three-dimensional calibration method
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4479385/
https://www.ncbi.nlm.nih.gov/pubmed/26157729
work_keys_str_mv AT hosseinialiabadisj improvementofaccuracyinenvironmentaldosimetrybytldcardsusingthreedimensionalcalibrationmethod
AT hosseinipooyasm improvementofaccuracyinenvironmentaldosimetrybytldcardsusingthreedimensionalcalibrationmethod
AT afaridehh improvementofaccuracyinenvironmentaldosimetrybytldcardsusingthreedimensionalcalibrationmethod
AT mianjif improvementofaccuracyinenvironmentaldosimetrybytldcardsusingthreedimensionalcalibrationmethod