Efficacy of Goal-Directed Therapy Using Bioreactance Cardiac Output Monitoring after Valvular Heart Surgery
PURPOSE: We compared the efficacy of postoperative hemodynamic goal-directed therapy (GDT) using a pulmonary artery catheter (PAC) and bioreactance-based noninvasive cardiac output monitoring (NICOM) in patients with atrial fibrillation undergoing valvular heart surgery. MATERIALS AND METHODS: Fifty...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Yonsei University College of Medicine
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4479857/ https://www.ncbi.nlm.nih.gov/pubmed/26069111 http://dx.doi.org/10.3349/ymj.2015.56.4.913 |
_version_ | 1782378075871248384 |
---|---|
author | Lee, Sak Lee, Seung Hyun Chang, Byung-Chul Shim, Jae-Kwang |
author_facet | Lee, Sak Lee, Seung Hyun Chang, Byung-Chul Shim, Jae-Kwang |
author_sort | Lee, Sak |
collection | PubMed |
description | PURPOSE: We compared the efficacy of postoperative hemodynamic goal-directed therapy (GDT) using a pulmonary artery catheter (PAC) and bioreactance-based noninvasive cardiac output monitoring (NICOM) in patients with atrial fibrillation undergoing valvular heart surgery. MATERIALS AND METHODS: Fifty eight patients were randomized into two groups of GDT with common goals to maintain a mean arterial pressure of 60-80 mm Hg and cardiac index ≥2 L/min/m(2): the PAC group (n=29), based on pulmonary capillary wedge pressure, and the NICOM group (n=29), based on changes in stroke volume index after passive leg raising. The primary efficacy variable was length of hospital stay. Secondary efficacy variables included resource utilization including vasopressor and inotropic requirement, fluid balance, and major morbidity endpoints. RESULTS: Patient characteristics and operative data were similar between the groups, except that significantly more patients underwent double valve replacement in the NICOM group. The lengths of hospital stay were not different between the two groups (12.2±4.8 days vs. 10.8±4.0 days, p=0.239). Numbers of patients requiring epinephrine (5 vs. 0, p=0.019) and ventilator care >24 h (6 vs. 1, p=0.044) were significantly higher in the PAC group. The PAC group also required significantly larger amounts of colloid (1652±519 mL vs. 11430±463 mL, p=0.004). CONCLUSION: NICOM-based postoperative hemodynamic GDT showed promising results in patients with atrial fibrillation undergoing valvular heart surgery in terms of resource utilization. |
format | Online Article Text |
id | pubmed-4479857 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Yonsei University College of Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-44798572015-07-01 Efficacy of Goal-Directed Therapy Using Bioreactance Cardiac Output Monitoring after Valvular Heart Surgery Lee, Sak Lee, Seung Hyun Chang, Byung-Chul Shim, Jae-Kwang Yonsei Med J Original Article PURPOSE: We compared the efficacy of postoperative hemodynamic goal-directed therapy (GDT) using a pulmonary artery catheter (PAC) and bioreactance-based noninvasive cardiac output monitoring (NICOM) in patients with atrial fibrillation undergoing valvular heart surgery. MATERIALS AND METHODS: Fifty eight patients were randomized into two groups of GDT with common goals to maintain a mean arterial pressure of 60-80 mm Hg and cardiac index ≥2 L/min/m(2): the PAC group (n=29), based on pulmonary capillary wedge pressure, and the NICOM group (n=29), based on changes in stroke volume index after passive leg raising. The primary efficacy variable was length of hospital stay. Secondary efficacy variables included resource utilization including vasopressor and inotropic requirement, fluid balance, and major morbidity endpoints. RESULTS: Patient characteristics and operative data were similar between the groups, except that significantly more patients underwent double valve replacement in the NICOM group. The lengths of hospital stay were not different between the two groups (12.2±4.8 days vs. 10.8±4.0 days, p=0.239). Numbers of patients requiring epinephrine (5 vs. 0, p=0.019) and ventilator care >24 h (6 vs. 1, p=0.044) were significantly higher in the PAC group. The PAC group also required significantly larger amounts of colloid (1652±519 mL vs. 11430±463 mL, p=0.004). CONCLUSION: NICOM-based postoperative hemodynamic GDT showed promising results in patients with atrial fibrillation undergoing valvular heart surgery in terms of resource utilization. Yonsei University College of Medicine 2015-07-01 2015-06-05 /pmc/articles/PMC4479857/ /pubmed/26069111 http://dx.doi.org/10.3349/ymj.2015.56.4.913 Text en © Copyright: Yonsei University College of Medicine 2015 http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Lee, Sak Lee, Seung Hyun Chang, Byung-Chul Shim, Jae-Kwang Efficacy of Goal-Directed Therapy Using Bioreactance Cardiac Output Monitoring after Valvular Heart Surgery |
title | Efficacy of Goal-Directed Therapy Using Bioreactance Cardiac Output Monitoring after Valvular Heart Surgery |
title_full | Efficacy of Goal-Directed Therapy Using Bioreactance Cardiac Output Monitoring after Valvular Heart Surgery |
title_fullStr | Efficacy of Goal-Directed Therapy Using Bioreactance Cardiac Output Monitoring after Valvular Heart Surgery |
title_full_unstemmed | Efficacy of Goal-Directed Therapy Using Bioreactance Cardiac Output Monitoring after Valvular Heart Surgery |
title_short | Efficacy of Goal-Directed Therapy Using Bioreactance Cardiac Output Monitoring after Valvular Heart Surgery |
title_sort | efficacy of goal-directed therapy using bioreactance cardiac output monitoring after valvular heart surgery |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4479857/ https://www.ncbi.nlm.nih.gov/pubmed/26069111 http://dx.doi.org/10.3349/ymj.2015.56.4.913 |
work_keys_str_mv | AT leesak efficacyofgoaldirectedtherapyusingbioreactancecardiacoutputmonitoringaftervalvularheartsurgery AT leeseunghyun efficacyofgoaldirectedtherapyusingbioreactancecardiacoutputmonitoringaftervalvularheartsurgery AT changbyungchul efficacyofgoaldirectedtherapyusingbioreactancecardiacoutputmonitoringaftervalvularheartsurgery AT shimjaekwang efficacyofgoaldirectedtherapyusingbioreactancecardiacoutputmonitoringaftervalvularheartsurgery |