Cargando…

Toward Clinically Compatible Phase-Contrast Mammography

Phase-contrast mammography using laboratory X-ray sources is a promising approach to overcome the relatively low sensitivity and specificity of clinical, absorption-based screening. Current research is mostly centered on identifying potential diagnostic benefits arising from phase-contrast and dark-...

Descripción completa

Detalles Bibliográficos
Autores principales: Scherer, Kai, Willer, Konstantin, Gromann, Lukas, Birnbacher, Lorenz, Braig, Eva, Grandl, Susanne, Sztrókay-Gaul, Anikó, Herzen, Julia, Mayr, Doris, Hellerhoff, Karin, Pfeiffer, Franz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4481352/
https://www.ncbi.nlm.nih.gov/pubmed/26110618
http://dx.doi.org/10.1371/journal.pone.0130776
_version_ 1782378269319888896
author Scherer, Kai
Willer, Konstantin
Gromann, Lukas
Birnbacher, Lorenz
Braig, Eva
Grandl, Susanne
Sztrókay-Gaul, Anikó
Herzen, Julia
Mayr, Doris
Hellerhoff, Karin
Pfeiffer, Franz
author_facet Scherer, Kai
Willer, Konstantin
Gromann, Lukas
Birnbacher, Lorenz
Braig, Eva
Grandl, Susanne
Sztrókay-Gaul, Anikó
Herzen, Julia
Mayr, Doris
Hellerhoff, Karin
Pfeiffer, Franz
author_sort Scherer, Kai
collection PubMed
description Phase-contrast mammography using laboratory X-ray sources is a promising approach to overcome the relatively low sensitivity and specificity of clinical, absorption-based screening. Current research is mostly centered on identifying potential diagnostic benefits arising from phase-contrast and dark-field mammography and benchmarking the latter with conventional state-of-the-art imaging methods. So far, little effort has been made to adjust this novel imaging technique to clinical needs. In this article, we address the key points for a successful implementation to a clinical routine in the near future and present the very first dose-compatible and rapid scan-time phase-contrast mammograms of both a freshly dissected, cancer-bearing mastectomy specimen and a mammographic accreditation phantom.
format Online
Article
Text
id pubmed-4481352
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-44813522015-07-01 Toward Clinically Compatible Phase-Contrast Mammography Scherer, Kai Willer, Konstantin Gromann, Lukas Birnbacher, Lorenz Braig, Eva Grandl, Susanne Sztrókay-Gaul, Anikó Herzen, Julia Mayr, Doris Hellerhoff, Karin Pfeiffer, Franz PLoS One Research Article Phase-contrast mammography using laboratory X-ray sources is a promising approach to overcome the relatively low sensitivity and specificity of clinical, absorption-based screening. Current research is mostly centered on identifying potential diagnostic benefits arising from phase-contrast and dark-field mammography and benchmarking the latter with conventional state-of-the-art imaging methods. So far, little effort has been made to adjust this novel imaging technique to clinical needs. In this article, we address the key points for a successful implementation to a clinical routine in the near future and present the very first dose-compatible and rapid scan-time phase-contrast mammograms of both a freshly dissected, cancer-bearing mastectomy specimen and a mammographic accreditation phantom. Public Library of Science 2015-06-25 /pmc/articles/PMC4481352/ /pubmed/26110618 http://dx.doi.org/10.1371/journal.pone.0130776 Text en © 2015 Scherer et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Scherer, Kai
Willer, Konstantin
Gromann, Lukas
Birnbacher, Lorenz
Braig, Eva
Grandl, Susanne
Sztrókay-Gaul, Anikó
Herzen, Julia
Mayr, Doris
Hellerhoff, Karin
Pfeiffer, Franz
Toward Clinically Compatible Phase-Contrast Mammography
title Toward Clinically Compatible Phase-Contrast Mammography
title_full Toward Clinically Compatible Phase-Contrast Mammography
title_fullStr Toward Clinically Compatible Phase-Contrast Mammography
title_full_unstemmed Toward Clinically Compatible Phase-Contrast Mammography
title_short Toward Clinically Compatible Phase-Contrast Mammography
title_sort toward clinically compatible phase-contrast mammography
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4481352/
https://www.ncbi.nlm.nih.gov/pubmed/26110618
http://dx.doi.org/10.1371/journal.pone.0130776
work_keys_str_mv AT schererkai towardclinicallycompatiblephasecontrastmammography
AT willerkonstantin towardclinicallycompatiblephasecontrastmammography
AT gromannlukas towardclinicallycompatiblephasecontrastmammography
AT birnbacherlorenz towardclinicallycompatiblephasecontrastmammography
AT braigeva towardclinicallycompatiblephasecontrastmammography
AT grandlsusanne towardclinicallycompatiblephasecontrastmammography
AT sztrokaygaulaniko towardclinicallycompatiblephasecontrastmammography
AT herzenjulia towardclinicallycompatiblephasecontrastmammography
AT mayrdoris towardclinicallycompatiblephasecontrastmammography
AT hellerhoffkarin towardclinicallycompatiblephasecontrastmammography
AT pfeifferfranz towardclinicallycompatiblephasecontrastmammography