Cargando…

Internal Rotation Behind-the-Back Angle: A Reliable Angular Measurement for Shoulder Internal Rotation Behind the Back

BACKGROUND: The hand-behind-back method is the accepted technique to evaluate shoulder internal rotation, is highly popular, and is endorsed by the American Academy of Orthopaedic Surgeons. It remains, however, subject to intra- and interexaminer discrepancy and has been challenged by several recent...

Descripción completa

Detalles Bibliográficos
Autor principal: Sraj, Shafic A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4481670/
https://www.ncbi.nlm.nih.gov/pubmed/26137173
http://dx.doi.org/10.1177/1941738113502159
_version_ 1782378306840035328
author Sraj, Shafic A.
author_facet Sraj, Shafic A.
author_sort Sraj, Shafic A.
collection PubMed
description BACKGROUND: The hand-behind-back method is the accepted technique to evaluate shoulder internal rotation, is highly popular, and is endorsed by the American Academy of Orthopaedic Surgeons. It remains, however, subject to intra- and interexaminer discrepancy and has been challenged by several recent publications. HYPOTHESIS: Internal rotation behind the back can be evaluated with a measurable angle, which eliminates the need to estimate spinal level, decreases the effect of unrelated joints, and allows collection of numeric rather than categoric data. STUDY DESIGN: Descriptive laboratory study. METHODS: We defined the internal rotation behind-the-back (IRB) angle as that between the ulna and the line of gravity. A pendulum is attached to a standard goniometer. The patient is asked to reach the highest point along the midline of the back. The goniometer is centered over the pisiform, and the angle between the ulnar axis and the pendulum is measured. Two examiners assessed both shoulders of 60 volunteers with no shoulder pathology using this technique on 2 occasions. Both examiners were blinded to each other’s values. We applied the paired Student t test and calculated Pearson correlation coefficients and weighted Cohen kappa values. RESULTS: The IRB angles ranged from 50° to 125°. The difference of the mean, as measured with the Student t test, was 0.6° (95% confidence interval: 0.1°, 1.3°) and 0.6° (95% confidence interval: −0.8°, 1.8°); the Pearson correlation coefficients were 0.98 and 0.92; and the weighted kappa values were 0.88 and 0.77 for interobserver and intraobserver analyses, respectively. CONCLUSION: The IRB angle is easy to measure, is reproducible, and does not rely on determination of spinal level. It provides numeric data and may eliminate some of the uncertainty associated with the estimation of spinal level. CLINICAL RELEVANCE: The IRB angle may eliminate some of the uncertainty associated with the estimation of spinal level.
format Online
Article
Text
id pubmed-4481670
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-44816702016-07-01 Internal Rotation Behind-the-Back Angle: A Reliable Angular Measurement for Shoulder Internal Rotation Behind the Back Sraj, Shafic A. Sports Health Focus Topic: Upper Extremity BACKGROUND: The hand-behind-back method is the accepted technique to evaluate shoulder internal rotation, is highly popular, and is endorsed by the American Academy of Orthopaedic Surgeons. It remains, however, subject to intra- and interexaminer discrepancy and has been challenged by several recent publications. HYPOTHESIS: Internal rotation behind the back can be evaluated with a measurable angle, which eliminates the need to estimate spinal level, decreases the effect of unrelated joints, and allows collection of numeric rather than categoric data. STUDY DESIGN: Descriptive laboratory study. METHODS: We defined the internal rotation behind-the-back (IRB) angle as that between the ulna and the line of gravity. A pendulum is attached to a standard goniometer. The patient is asked to reach the highest point along the midline of the back. The goniometer is centered over the pisiform, and the angle between the ulnar axis and the pendulum is measured. Two examiners assessed both shoulders of 60 volunteers with no shoulder pathology using this technique on 2 occasions. Both examiners were blinded to each other’s values. We applied the paired Student t test and calculated Pearson correlation coefficients and weighted Cohen kappa values. RESULTS: The IRB angles ranged from 50° to 125°. The difference of the mean, as measured with the Student t test, was 0.6° (95% confidence interval: 0.1°, 1.3°) and 0.6° (95% confidence interval: −0.8°, 1.8°); the Pearson correlation coefficients were 0.98 and 0.92; and the weighted kappa values were 0.88 and 0.77 for interobserver and intraobserver analyses, respectively. CONCLUSION: The IRB angle is easy to measure, is reproducible, and does not rely on determination of spinal level. It provides numeric data and may eliminate some of the uncertainty associated with the estimation of spinal level. CLINICAL RELEVANCE: The IRB angle may eliminate some of the uncertainty associated with the estimation of spinal level. SAGE Publications 2015-07 /pmc/articles/PMC4481670/ /pubmed/26137173 http://dx.doi.org/10.1177/1941738113502159 Text en © 2013 The Author(s)
spellingShingle Focus Topic: Upper Extremity
Sraj, Shafic A.
Internal Rotation Behind-the-Back Angle: A Reliable Angular Measurement for Shoulder Internal Rotation Behind the Back
title Internal Rotation Behind-the-Back Angle: A Reliable Angular Measurement for Shoulder Internal Rotation Behind the Back
title_full Internal Rotation Behind-the-Back Angle: A Reliable Angular Measurement for Shoulder Internal Rotation Behind the Back
title_fullStr Internal Rotation Behind-the-Back Angle: A Reliable Angular Measurement for Shoulder Internal Rotation Behind the Back
title_full_unstemmed Internal Rotation Behind-the-Back Angle: A Reliable Angular Measurement for Shoulder Internal Rotation Behind the Back
title_short Internal Rotation Behind-the-Back Angle: A Reliable Angular Measurement for Shoulder Internal Rotation Behind the Back
title_sort internal rotation behind-the-back angle: a reliable angular measurement for shoulder internal rotation behind the back
topic Focus Topic: Upper Extremity
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4481670/
https://www.ncbi.nlm.nih.gov/pubmed/26137173
http://dx.doi.org/10.1177/1941738113502159
work_keys_str_mv AT srajshafica internalrotationbehindthebackangleareliableangularmeasurementforshoulderinternalrotationbehindtheback