Cargando…
Internal Rotation Behind-the-Back Angle: A Reliable Angular Measurement for Shoulder Internal Rotation Behind the Back
BACKGROUND: The hand-behind-back method is the accepted technique to evaluate shoulder internal rotation, is highly popular, and is endorsed by the American Academy of Orthopaedic Surgeons. It remains, however, subject to intra- and interexaminer discrepancy and has been challenged by several recent...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4481670/ https://www.ncbi.nlm.nih.gov/pubmed/26137173 http://dx.doi.org/10.1177/1941738113502159 |
_version_ | 1782378306840035328 |
---|---|
author | Sraj, Shafic A. |
author_facet | Sraj, Shafic A. |
author_sort | Sraj, Shafic A. |
collection | PubMed |
description | BACKGROUND: The hand-behind-back method is the accepted technique to evaluate shoulder internal rotation, is highly popular, and is endorsed by the American Academy of Orthopaedic Surgeons. It remains, however, subject to intra- and interexaminer discrepancy and has been challenged by several recent publications. HYPOTHESIS: Internal rotation behind the back can be evaluated with a measurable angle, which eliminates the need to estimate spinal level, decreases the effect of unrelated joints, and allows collection of numeric rather than categoric data. STUDY DESIGN: Descriptive laboratory study. METHODS: We defined the internal rotation behind-the-back (IRB) angle as that between the ulna and the line of gravity. A pendulum is attached to a standard goniometer. The patient is asked to reach the highest point along the midline of the back. The goniometer is centered over the pisiform, and the angle between the ulnar axis and the pendulum is measured. Two examiners assessed both shoulders of 60 volunteers with no shoulder pathology using this technique on 2 occasions. Both examiners were blinded to each other’s values. We applied the paired Student t test and calculated Pearson correlation coefficients and weighted Cohen kappa values. RESULTS: The IRB angles ranged from 50° to 125°. The difference of the mean, as measured with the Student t test, was 0.6° (95% confidence interval: 0.1°, 1.3°) and 0.6° (95% confidence interval: −0.8°, 1.8°); the Pearson correlation coefficients were 0.98 and 0.92; and the weighted kappa values were 0.88 and 0.77 for interobserver and intraobserver analyses, respectively. CONCLUSION: The IRB angle is easy to measure, is reproducible, and does not rely on determination of spinal level. It provides numeric data and may eliminate some of the uncertainty associated with the estimation of spinal level. CLINICAL RELEVANCE: The IRB angle may eliminate some of the uncertainty associated with the estimation of spinal level. |
format | Online Article Text |
id | pubmed-4481670 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-44816702016-07-01 Internal Rotation Behind-the-Back Angle: A Reliable Angular Measurement for Shoulder Internal Rotation Behind the Back Sraj, Shafic A. Sports Health Focus Topic: Upper Extremity BACKGROUND: The hand-behind-back method is the accepted technique to evaluate shoulder internal rotation, is highly popular, and is endorsed by the American Academy of Orthopaedic Surgeons. It remains, however, subject to intra- and interexaminer discrepancy and has been challenged by several recent publications. HYPOTHESIS: Internal rotation behind the back can be evaluated with a measurable angle, which eliminates the need to estimate spinal level, decreases the effect of unrelated joints, and allows collection of numeric rather than categoric data. STUDY DESIGN: Descriptive laboratory study. METHODS: We defined the internal rotation behind-the-back (IRB) angle as that between the ulna and the line of gravity. A pendulum is attached to a standard goniometer. The patient is asked to reach the highest point along the midline of the back. The goniometer is centered over the pisiform, and the angle between the ulnar axis and the pendulum is measured. Two examiners assessed both shoulders of 60 volunteers with no shoulder pathology using this technique on 2 occasions. Both examiners were blinded to each other’s values. We applied the paired Student t test and calculated Pearson correlation coefficients and weighted Cohen kappa values. RESULTS: The IRB angles ranged from 50° to 125°. The difference of the mean, as measured with the Student t test, was 0.6° (95% confidence interval: 0.1°, 1.3°) and 0.6° (95% confidence interval: −0.8°, 1.8°); the Pearson correlation coefficients were 0.98 and 0.92; and the weighted kappa values were 0.88 and 0.77 for interobserver and intraobserver analyses, respectively. CONCLUSION: The IRB angle is easy to measure, is reproducible, and does not rely on determination of spinal level. It provides numeric data and may eliminate some of the uncertainty associated with the estimation of spinal level. CLINICAL RELEVANCE: The IRB angle may eliminate some of the uncertainty associated with the estimation of spinal level. SAGE Publications 2015-07 /pmc/articles/PMC4481670/ /pubmed/26137173 http://dx.doi.org/10.1177/1941738113502159 Text en © 2013 The Author(s) |
spellingShingle | Focus Topic: Upper Extremity Sraj, Shafic A. Internal Rotation Behind-the-Back Angle: A Reliable Angular Measurement for Shoulder Internal Rotation Behind the Back |
title | Internal Rotation Behind-the-Back Angle: A Reliable Angular Measurement for Shoulder Internal Rotation Behind the Back |
title_full | Internal Rotation Behind-the-Back Angle: A Reliable Angular Measurement for Shoulder Internal Rotation Behind the Back |
title_fullStr | Internal Rotation Behind-the-Back Angle: A Reliable Angular Measurement for Shoulder Internal Rotation Behind the Back |
title_full_unstemmed | Internal Rotation Behind-the-Back Angle: A Reliable Angular Measurement for Shoulder Internal Rotation Behind the Back |
title_short | Internal Rotation Behind-the-Back Angle: A Reliable Angular Measurement for Shoulder Internal Rotation Behind the Back |
title_sort | internal rotation behind-the-back angle: a reliable angular measurement for shoulder internal rotation behind the back |
topic | Focus Topic: Upper Extremity |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4481670/ https://www.ncbi.nlm.nih.gov/pubmed/26137173 http://dx.doi.org/10.1177/1941738113502159 |
work_keys_str_mv | AT srajshafica internalrotationbehindthebackangleareliableangularmeasurementforshoulderinternalrotationbehindtheback |