Cargando…

Intra and inter-rater reliability study of pelvic floor muscle dynamometric measurements

OBJECTIVE: The aim of this study was to evaluate the intra and inter-rater reliability of pelvic floor muscle (PFM) dynamometric measurements for maximum and average strengths, as well as endurance. METHOD: A convenience sample of 18 nulliparous women, without any urogynecological complaints, aged b...

Descripción completa

Detalles Bibliográficos
Autores principales: Martinho, Natalia M., Marques, Joseane, Silva, Valéria R., Silva, Silvia L. A., Carvalho, Leonardo C., Botelho, Simone
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4481829/
https://www.ncbi.nlm.nih.gov/pubmed/25993624
http://dx.doi.org/10.1590/bjpt-rbf.2014.0083
_version_ 1782378331839135744
author Martinho, Natalia M.
Marques, Joseane
Silva, Valéria R.
Silva, Silvia L. A.
Carvalho, Leonardo C.
Botelho, Simone
author_facet Martinho, Natalia M.
Marques, Joseane
Silva, Valéria R.
Silva, Silvia L. A.
Carvalho, Leonardo C.
Botelho, Simone
author_sort Martinho, Natalia M.
collection PubMed
description OBJECTIVE: The aim of this study was to evaluate the intra and inter-rater reliability of pelvic floor muscle (PFM) dynamometric measurements for maximum and average strengths, as well as endurance. METHOD: A convenience sample of 18 nulliparous women, without any urogynecological complaints, aged between 19 and 31 (mean age of 25.4±3.9) participated in this study. They were evaluated using a pelvic floor dynamometer based on load cell technology. The dynamometric evaluations were repeated in three successive sessions: two on the same day with a rest period of 30 minutes between them, and the third on the following day. All participants were evaluated twice in each session; first by examiner 1 followed by examiner 2. The vaginal dynamometry data were analyzed using three parameters: maximum strength, average strength, and endurance. The Intraclass Correlation Coefficient (ICC) was applied to estimate the PFM dynamometric measurement reliability, considering a good level as being above 0.75. RESULTS: The intra and inter-raters' analyses showed good reliability for maximum strength (ICC(intra-rater1)=0.96, ICC(intra-rater2)=0.95, and ICC(inter-rater)=0.96), average strength (ICC(intra-rater1)=0.96, ICC(intra-rater2)=0.94, and ICC(inter-rater)=0.97), and endurance (ICC(intra-rater1)=0.88, ICC(intra-rater2)=0.86, and ICC(inter-rater)=0.92) dynamometric measurements. CONCLUSIONS: The PFM dynamometric measurements showed good intra- and inter-rater reliability for maximum strength, average strength and endurance, which demonstrates that this is a reliable device that can be used in clinical practice.
format Online
Article
Text
id pubmed-4481829
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia
record_format MEDLINE/PubMed
spelling pubmed-44818292015-07-17 Intra and inter-rater reliability study of pelvic floor muscle dynamometric measurements Martinho, Natalia M. Marques, Joseane Silva, Valéria R. Silva, Silvia L. A. Carvalho, Leonardo C. Botelho, Simone Braz J Phys Ther Original Articles OBJECTIVE: The aim of this study was to evaluate the intra and inter-rater reliability of pelvic floor muscle (PFM) dynamometric measurements for maximum and average strengths, as well as endurance. METHOD: A convenience sample of 18 nulliparous women, without any urogynecological complaints, aged between 19 and 31 (mean age of 25.4±3.9) participated in this study. They were evaluated using a pelvic floor dynamometer based on load cell technology. The dynamometric evaluations were repeated in three successive sessions: two on the same day with a rest period of 30 minutes between them, and the third on the following day. All participants were evaluated twice in each session; first by examiner 1 followed by examiner 2. The vaginal dynamometry data were analyzed using three parameters: maximum strength, average strength, and endurance. The Intraclass Correlation Coefficient (ICC) was applied to estimate the PFM dynamometric measurement reliability, considering a good level as being above 0.75. RESULTS: The intra and inter-raters' analyses showed good reliability for maximum strength (ICC(intra-rater1)=0.96, ICC(intra-rater2)=0.95, and ICC(inter-rater)=0.96), average strength (ICC(intra-rater1)=0.96, ICC(intra-rater2)=0.94, and ICC(inter-rater)=0.97), and endurance (ICC(intra-rater1)=0.88, ICC(intra-rater2)=0.86, and ICC(inter-rater)=0.92) dynamometric measurements. CONCLUSIONS: The PFM dynamometric measurements showed good intra- and inter-rater reliability for maximum strength, average strength and endurance, which demonstrates that this is a reliable device that can be used in clinical practice. Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia 2015-04-27 2015 /pmc/articles/PMC4481829/ /pubmed/25993624 http://dx.doi.org/10.1590/bjpt-rbf.2014.0083 Text en http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Articles
Martinho, Natalia M.
Marques, Joseane
Silva, Valéria R.
Silva, Silvia L. A.
Carvalho, Leonardo C.
Botelho, Simone
Intra and inter-rater reliability study of pelvic floor muscle dynamometric measurements
title Intra and inter-rater reliability study of pelvic floor muscle dynamometric measurements
title_full Intra and inter-rater reliability study of pelvic floor muscle dynamometric measurements
title_fullStr Intra and inter-rater reliability study of pelvic floor muscle dynamometric measurements
title_full_unstemmed Intra and inter-rater reliability study of pelvic floor muscle dynamometric measurements
title_short Intra and inter-rater reliability study of pelvic floor muscle dynamometric measurements
title_sort intra and inter-rater reliability study of pelvic floor muscle dynamometric measurements
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4481829/
https://www.ncbi.nlm.nih.gov/pubmed/25993624
http://dx.doi.org/10.1590/bjpt-rbf.2014.0083
work_keys_str_mv AT martinhonataliam intraandinterraterreliabilitystudyofpelvicfloormuscledynamometricmeasurements
AT marquesjoseane intraandinterraterreliabilitystudyofpelvicfloormuscledynamometricmeasurements
AT silvavaleriar intraandinterraterreliabilitystudyofpelvicfloormuscledynamometricmeasurements
AT silvasilviala intraandinterraterreliabilitystudyofpelvicfloormuscledynamometricmeasurements
AT carvalholeonardoc intraandinterraterreliabilitystudyofpelvicfloormuscledynamometricmeasurements
AT botelhosimone intraandinterraterreliabilitystudyofpelvicfloormuscledynamometricmeasurements