Cargando…

Highly Sensitive Bacteria Quantification Using Immunomagnetic Separation and Electrochemical Detection of Guanine-Labeled Secondary Beads

In this paper, we report the ultra-sensitive indirect electrochemical detection of E. coli O157:H7 using antibody functionalized primary (magnetic) beads for capture and polyguanine (polyG) oligonucleotide functionalized secondary (polystyrene) beads as an electrochemical tag. Vacuum filtration in c...

Descripción completa

Detalles Bibliográficos
Autores principales: Jayamohan, Harikrishnan, Gale, Bruce K., Minson, Bj, Lambert, Christopher J., Gordon, Neil, Sant, Himanshu J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4481928/
https://www.ncbi.nlm.nih.gov/pubmed/26007743
http://dx.doi.org/10.3390/s150512034
_version_ 1782378348422365184
author Jayamohan, Harikrishnan
Gale, Bruce K.
Minson, Bj
Lambert, Christopher J.
Gordon, Neil
Sant, Himanshu J.
author_facet Jayamohan, Harikrishnan
Gale, Bruce K.
Minson, Bj
Lambert, Christopher J.
Gordon, Neil
Sant, Himanshu J.
author_sort Jayamohan, Harikrishnan
collection PubMed
description In this paper, we report the ultra-sensitive indirect electrochemical detection of E. coli O157:H7 using antibody functionalized primary (magnetic) beads for capture and polyguanine (polyG) oligonucleotide functionalized secondary (polystyrene) beads as an electrochemical tag. Vacuum filtration in combination with E. coli O157:H7 specific antibody modified magnetic beads were used for extraction of E. coli O157:H7 from 100 mL samples. The magnetic bead conjugated E. coli O157:H7 cells were then attached to polyG functionalized secondary beads to form a sandwich complex (magnetic bead/E. coli/ secondary bead). While the use of magnetic beads for immuno-based capture is well characterized, the use of oligonucleotide functionalized secondary beads helps combine amplification and potential multiplexing into the system. The antibody functionalized secondary beads can be easily modified with a different antibody to detect other pathogens from the same sample and enable potential multiplexing. The polyGs on the secondary beads enable signal amplification up to 10(8) guanine tags per secondary bead (7.5 × 10(6) biotin-FITC per secondary bead, 20 guanines per oligonucleotide) bound to the target (E. coli). A single-stranded DNA probe functionalized reduced graphene oxide modified glassy carbon electrode was used to bind the polyGs on the secondary beads. Fluorescent imaging was performed to confirm the hybridization of the complex to the electrode surface. Differential pulse voltammetry (DPV) was used to quantify the amount of polyG involved in the hybridization event with tris(2,2′-bipyridine)ruthenium(II) ( [Formula: see text]) as the mediator. The amount of polyG signal can be correlated to the amount of E. coli O157:H7 in the sample. The method was able to detect concentrations of E. coli O157:H7 down to 3 CFU/100 mL, which is 67 times lower than the most sensitive technique reported in literature. The signal to noise ratio for this work was 3. We also demonstrate the use of the protocol for detection of E. coli O157:H7 seeded in waste water effluent samples.
format Online
Article
Text
id pubmed-4481928
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-44819282015-06-29 Highly Sensitive Bacteria Quantification Using Immunomagnetic Separation and Electrochemical Detection of Guanine-Labeled Secondary Beads Jayamohan, Harikrishnan Gale, Bruce K. Minson, Bj Lambert, Christopher J. Gordon, Neil Sant, Himanshu J. Sensors (Basel) Article In this paper, we report the ultra-sensitive indirect electrochemical detection of E. coli O157:H7 using antibody functionalized primary (magnetic) beads for capture and polyguanine (polyG) oligonucleotide functionalized secondary (polystyrene) beads as an electrochemical tag. Vacuum filtration in combination with E. coli O157:H7 specific antibody modified magnetic beads were used for extraction of E. coli O157:H7 from 100 mL samples. The magnetic bead conjugated E. coli O157:H7 cells were then attached to polyG functionalized secondary beads to form a sandwich complex (magnetic bead/E. coli/ secondary bead). While the use of magnetic beads for immuno-based capture is well characterized, the use of oligonucleotide functionalized secondary beads helps combine amplification and potential multiplexing into the system. The antibody functionalized secondary beads can be easily modified with a different antibody to detect other pathogens from the same sample and enable potential multiplexing. The polyGs on the secondary beads enable signal amplification up to 10(8) guanine tags per secondary bead (7.5 × 10(6) biotin-FITC per secondary bead, 20 guanines per oligonucleotide) bound to the target (E. coli). A single-stranded DNA probe functionalized reduced graphene oxide modified glassy carbon electrode was used to bind the polyGs on the secondary beads. Fluorescent imaging was performed to confirm the hybridization of the complex to the electrode surface. Differential pulse voltammetry (DPV) was used to quantify the amount of polyG involved in the hybridization event with tris(2,2′-bipyridine)ruthenium(II) ( [Formula: see text]) as the mediator. The amount of polyG signal can be correlated to the amount of E. coli O157:H7 in the sample. The method was able to detect concentrations of E. coli O157:H7 down to 3 CFU/100 mL, which is 67 times lower than the most sensitive technique reported in literature. The signal to noise ratio for this work was 3. We also demonstrate the use of the protocol for detection of E. coli O157:H7 seeded in waste water effluent samples. MDPI 2015-05-22 /pmc/articles/PMC4481928/ /pubmed/26007743 http://dx.doi.org/10.3390/s150512034 Text en © 2015 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Jayamohan, Harikrishnan
Gale, Bruce K.
Minson, Bj
Lambert, Christopher J.
Gordon, Neil
Sant, Himanshu J.
Highly Sensitive Bacteria Quantification Using Immunomagnetic Separation and Electrochemical Detection of Guanine-Labeled Secondary Beads
title Highly Sensitive Bacteria Quantification Using Immunomagnetic Separation and Electrochemical Detection of Guanine-Labeled Secondary Beads
title_full Highly Sensitive Bacteria Quantification Using Immunomagnetic Separation and Electrochemical Detection of Guanine-Labeled Secondary Beads
title_fullStr Highly Sensitive Bacteria Quantification Using Immunomagnetic Separation and Electrochemical Detection of Guanine-Labeled Secondary Beads
title_full_unstemmed Highly Sensitive Bacteria Quantification Using Immunomagnetic Separation and Electrochemical Detection of Guanine-Labeled Secondary Beads
title_short Highly Sensitive Bacteria Quantification Using Immunomagnetic Separation and Electrochemical Detection of Guanine-Labeled Secondary Beads
title_sort highly sensitive bacteria quantification using immunomagnetic separation and electrochemical detection of guanine-labeled secondary beads
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4481928/
https://www.ncbi.nlm.nih.gov/pubmed/26007743
http://dx.doi.org/10.3390/s150512034
work_keys_str_mv AT jayamohanharikrishnan highlysensitivebacteriaquantificationusingimmunomagneticseparationandelectrochemicaldetectionofguaninelabeledsecondarybeads
AT galebrucek highlysensitivebacteriaquantificationusingimmunomagneticseparationandelectrochemicaldetectionofguaninelabeledsecondarybeads
AT minsonbj highlysensitivebacteriaquantificationusingimmunomagneticseparationandelectrochemicaldetectionofguaninelabeledsecondarybeads
AT lambertchristopherj highlysensitivebacteriaquantificationusingimmunomagneticseparationandelectrochemicaldetectionofguaninelabeledsecondarybeads
AT gordonneil highlysensitivebacteriaquantificationusingimmunomagneticseparationandelectrochemicaldetectionofguaninelabeledsecondarybeads
AT santhimanshuj highlysensitivebacteriaquantificationusingimmunomagneticseparationandelectrochemicaldetectionofguaninelabeledsecondarybeads