PURPOSE: This study evaluated the effect of various head orientations during cone-beam computed tomography (CBCT) image acquisition on linear measurements of potential implant sites. MATERIALS AND METHODS: Six dry human skulls with a total of 28 implant sites were evaluated for seven different head...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Academy of Oral and Maxillofacial Radiology
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4483623/ https://www.ncbi.nlm.nih.gov/pubmed/26125001 http://dx.doi.org/10.5624/isd.2015.45.2.73 |
_version_ | 1782378584242913280 |
---|---|
author | Sabban, Hanadi Mahdian, Mina Dhingra, Ajay Lurie, Alan G. Tadinada, Aditya |
author_facet | Sabban, Hanadi Mahdian, Mina Dhingra, Ajay Lurie, Alan G. Tadinada, Aditya |
author_sort | Sabban, Hanadi |
collection | PubMed |
description | PURPOSE: This study evaluated the effect of various head orientations during cone-beam computed tomography (CBCT) image acquisition on linear measurements of potential implant sites. MATERIALS AND METHODS: Six dry human skulls with a total of 28 implant sites were evaluated for seven different head orientations. The scans were acquired using a Hitachi CB-MercuRay CBCT machine. The scanned volumes were reconstructed. Horizontal and vertical measurements were made and were compared to measurements made after simulating the head position to corrected head angulations. Data was analyzed using a two-way ANOVA test. RESULTS: Statistical analysis revealed a significant interaction between the mean errors in vertical measurements with a marked difference observed at the extension head position (P<0.05). Statistical analysis failed to yield any significant interaction between the mean errors in horizontal measurements at various head positions. CONCLUSION: Head orientation could significantly affect the vertical measurements in CBCT scans. The main head position influencing the measurements is extension. |
format | Online Article Text |
id | pubmed-4483623 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Korean Academy of Oral and Maxillofacial Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-44836232015-06-29 Evaluation of linear measurements of implant sites based on head orientation during acquisition: An ex vivo study using cone-beam computed tomography Sabban, Hanadi Mahdian, Mina Dhingra, Ajay Lurie, Alan G. Tadinada, Aditya Imaging Sci Dent Original Article PURPOSE: This study evaluated the effect of various head orientations during cone-beam computed tomography (CBCT) image acquisition on linear measurements of potential implant sites. MATERIALS AND METHODS: Six dry human skulls with a total of 28 implant sites were evaluated for seven different head orientations. The scans were acquired using a Hitachi CB-MercuRay CBCT machine. The scanned volumes were reconstructed. Horizontal and vertical measurements were made and were compared to measurements made after simulating the head position to corrected head angulations. Data was analyzed using a two-way ANOVA test. RESULTS: Statistical analysis revealed a significant interaction between the mean errors in vertical measurements with a marked difference observed at the extension head position (P<0.05). Statistical analysis failed to yield any significant interaction between the mean errors in horizontal measurements at various head positions. CONCLUSION: Head orientation could significantly affect the vertical measurements in CBCT scans. The main head position influencing the measurements is extension. Korean Academy of Oral and Maxillofacial Radiology 2015-06 2015-06-19 /pmc/articles/PMC4483623/ /pubmed/26125001 http://dx.doi.org/10.5624/isd.2015.45.2.73 Text en Copyright © 2015 by Korean Academy of Oral and Maxillofacial Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Sabban, Hanadi Mahdian, Mina Dhingra, Ajay Lurie, Alan G. Tadinada, Aditya Evaluation of linear measurements of implant sites based on head orientation during acquisition: An ex vivo study using cone-beam computed tomography |
title | Evaluation of linear measurements of implant sites based on head orientation during acquisition: An ex vivo study using cone-beam computed tomography |
title_full | Evaluation of linear measurements of implant sites based on head orientation during acquisition: An ex vivo study using cone-beam computed tomography |
title_fullStr | Evaluation of linear measurements of implant sites based on head orientation during acquisition: An ex vivo study using cone-beam computed tomography |
title_full_unstemmed | Evaluation of linear measurements of implant sites based on head orientation during acquisition: An ex vivo study using cone-beam computed tomography |
title_short | Evaluation of linear measurements of implant sites based on head orientation during acquisition: An ex vivo study using cone-beam computed tomography |
title_sort | evaluation of linear measurements of implant sites based on head orientation during acquisition: an ex vivo study using cone-beam computed tomography |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4483623/ https://www.ncbi.nlm.nih.gov/pubmed/26125001 http://dx.doi.org/10.5624/isd.2015.45.2.73 |
work_keys_str_mv | AT sabbanhanadi evaluationoflinearmeasurementsofimplantsitesbasedonheadorientationduringacquisitionanexvivostudyusingconebeamcomputedtomography AT mahdianmina evaluationoflinearmeasurementsofimplantsitesbasedonheadorientationduringacquisitionanexvivostudyusingconebeamcomputedtomography AT dhingraajay evaluationoflinearmeasurementsofimplantsitesbasedonheadorientationduringacquisitionanexvivostudyusingconebeamcomputedtomography AT luriealang evaluationoflinearmeasurementsofimplantsitesbasedonheadorientationduringacquisitionanexvivostudyusingconebeamcomputedtomography AT tadinadaaditya evaluationoflinearmeasurementsofimplantsitesbasedonheadorientationduringacquisitionanexvivostudyusingconebeamcomputedtomography |