Cargando…

Evaluation of linear measurements of implant sites based on head orientation during acquisition: An ex vivo study using cone-beam computed tomography

PURPOSE: This study evaluated the effect of various head orientations during cone-beam computed tomography (CBCT) image acquisition on linear measurements of potential implant sites. MATERIALS AND METHODS: Six dry human skulls with a total of 28 implant sites were evaluated for seven different head...

Descripción completa

Detalles Bibliográficos
Autores principales: Sabban, Hanadi, Mahdian, Mina, Dhingra, Ajay, Lurie, Alan G., Tadinada, Aditya
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Academy of Oral and Maxillofacial Radiology 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4483623/
https://www.ncbi.nlm.nih.gov/pubmed/26125001
http://dx.doi.org/10.5624/isd.2015.45.2.73
_version_ 1782378584242913280
author Sabban, Hanadi
Mahdian, Mina
Dhingra, Ajay
Lurie, Alan G.
Tadinada, Aditya
author_facet Sabban, Hanadi
Mahdian, Mina
Dhingra, Ajay
Lurie, Alan G.
Tadinada, Aditya
author_sort Sabban, Hanadi
collection PubMed
description PURPOSE: This study evaluated the effect of various head orientations during cone-beam computed tomography (CBCT) image acquisition on linear measurements of potential implant sites. MATERIALS AND METHODS: Six dry human skulls with a total of 28 implant sites were evaluated for seven different head orientations. The scans were acquired using a Hitachi CB-MercuRay CBCT machine. The scanned volumes were reconstructed. Horizontal and vertical measurements were made and were compared to measurements made after simulating the head position to corrected head angulations. Data was analyzed using a two-way ANOVA test. RESULTS: Statistical analysis revealed a significant interaction between the mean errors in vertical measurements with a marked difference observed at the extension head position (P<0.05). Statistical analysis failed to yield any significant interaction between the mean errors in horizontal measurements at various head positions. CONCLUSION: Head orientation could significantly affect the vertical measurements in CBCT scans. The main head position influencing the measurements is extension.
format Online
Article
Text
id pubmed-4483623
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Korean Academy of Oral and Maxillofacial Radiology
record_format MEDLINE/PubMed
spelling pubmed-44836232015-06-29 Evaluation of linear measurements of implant sites based on head orientation during acquisition: An ex vivo study using cone-beam computed tomography Sabban, Hanadi Mahdian, Mina Dhingra, Ajay Lurie, Alan G. Tadinada, Aditya Imaging Sci Dent Original Article PURPOSE: This study evaluated the effect of various head orientations during cone-beam computed tomography (CBCT) image acquisition on linear measurements of potential implant sites. MATERIALS AND METHODS: Six dry human skulls with a total of 28 implant sites were evaluated for seven different head orientations. The scans were acquired using a Hitachi CB-MercuRay CBCT machine. The scanned volumes were reconstructed. Horizontal and vertical measurements were made and were compared to measurements made after simulating the head position to corrected head angulations. Data was analyzed using a two-way ANOVA test. RESULTS: Statistical analysis revealed a significant interaction between the mean errors in vertical measurements with a marked difference observed at the extension head position (P<0.05). Statistical analysis failed to yield any significant interaction between the mean errors in horizontal measurements at various head positions. CONCLUSION: Head orientation could significantly affect the vertical measurements in CBCT scans. The main head position influencing the measurements is extension. Korean Academy of Oral and Maxillofacial Radiology 2015-06 2015-06-19 /pmc/articles/PMC4483623/ /pubmed/26125001 http://dx.doi.org/10.5624/isd.2015.45.2.73 Text en Copyright © 2015 by Korean Academy of Oral and Maxillofacial Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Sabban, Hanadi
Mahdian, Mina
Dhingra, Ajay
Lurie, Alan G.
Tadinada, Aditya
Evaluation of linear measurements of implant sites based on head orientation during acquisition: An ex vivo study using cone-beam computed tomography
title Evaluation of linear measurements of implant sites based on head orientation during acquisition: An ex vivo study using cone-beam computed tomography
title_full Evaluation of linear measurements of implant sites based on head orientation during acquisition: An ex vivo study using cone-beam computed tomography
title_fullStr Evaluation of linear measurements of implant sites based on head orientation during acquisition: An ex vivo study using cone-beam computed tomography
title_full_unstemmed Evaluation of linear measurements of implant sites based on head orientation during acquisition: An ex vivo study using cone-beam computed tomography
title_short Evaluation of linear measurements of implant sites based on head orientation during acquisition: An ex vivo study using cone-beam computed tomography
title_sort evaluation of linear measurements of implant sites based on head orientation during acquisition: an ex vivo study using cone-beam computed tomography
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4483623/
https://www.ncbi.nlm.nih.gov/pubmed/26125001
http://dx.doi.org/10.5624/isd.2015.45.2.73
work_keys_str_mv AT sabbanhanadi evaluationoflinearmeasurementsofimplantsitesbasedonheadorientationduringacquisitionanexvivostudyusingconebeamcomputedtomography
AT mahdianmina evaluationoflinearmeasurementsofimplantsitesbasedonheadorientationduringacquisitionanexvivostudyusingconebeamcomputedtomography
AT dhingraajay evaluationoflinearmeasurementsofimplantsitesbasedonheadorientationduringacquisitionanexvivostudyusingconebeamcomputedtomography
AT luriealang evaluationoflinearmeasurementsofimplantsitesbasedonheadorientationduringacquisitionanexvivostudyusingconebeamcomputedtomography
AT tadinadaaditya evaluationoflinearmeasurementsofimplantsitesbasedonheadorientationduringacquisitionanexvivostudyusingconebeamcomputedtomography