Assessment of Electromagnetic Interference with Active Cardiovascular Implantable Electronic Devices (CIEDs) Caused by the Qi A13 Design Wireless Charging Board

Electromagnetic interference is a concern for people wearing cardiovascular implantable electronic devices (CIEDs). The aim of this study was to assess the electromagnetic compatibility between CIEDs and the magnetic field of a common wireless charging technology. To do so the voltage induced in CIE...

Descripción completa

Detalles Bibliográficos
Autores principales: Seckler, Tobias, Jagielski, Kai, Stunder, Dominik
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4483677/
https://www.ncbi.nlm.nih.gov/pubmed/26024360
http://dx.doi.org/10.3390/ijerph120605886
_version_ 1782378596503912448
author Seckler, Tobias
Jagielski, Kai
Stunder, Dominik
author_facet Seckler, Tobias
Jagielski, Kai
Stunder, Dominik
author_sort Seckler, Tobias
collection PubMed
description Electromagnetic interference is a concern for people wearing cardiovascular implantable electronic devices (CIEDs). The aim of this study was to assess the electromagnetic compatibility between CIEDs and the magnetic field of a common wireless charging technology. To do so the voltage induced in CIEDs by Qi A13 design magnetic fields were measured and compared with the performance limits set by ISO 14117. In order to carry this out a measuring circuit was developed which can be connected with unipolar or bipolar pacemaker leads. The measuring system was positioned at the four most common implantation sites in a torso phantom filled with physiological saline solution. The phantom was exposed by using Helmholtz coils from 5 µT to 27 µT with 111 kHz sine-bursts or by using a Qi A13 design wireless charging board (Qi-A13-Board) in two operating modes “power transfer” and “pinging”. With the Helmholtz coils the lowest magnetic flux density at which the performance limit was exceeded is 11 µT. With the Qi-A13-Board in power transfer mode 10.8% and in pinging mode 45.7% (2.2% at 10 cm distance) of the performance limit were reached at maximum. In neither of the scrutinized cases, did the voltage induced by the Qi-A13-Board exceed the performance limits.
format Online
Article
Text
id pubmed-4483677
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-44836772015-06-30 Assessment of Electromagnetic Interference with Active Cardiovascular Implantable Electronic Devices (CIEDs) Caused by the Qi A13 Design Wireless Charging Board Seckler, Tobias Jagielski, Kai Stunder, Dominik Int J Environ Res Public Health Article Electromagnetic interference is a concern for people wearing cardiovascular implantable electronic devices (CIEDs). The aim of this study was to assess the electromagnetic compatibility between CIEDs and the magnetic field of a common wireless charging technology. To do so the voltage induced in CIEDs by Qi A13 design magnetic fields were measured and compared with the performance limits set by ISO 14117. In order to carry this out a measuring circuit was developed which can be connected with unipolar or bipolar pacemaker leads. The measuring system was positioned at the four most common implantation sites in a torso phantom filled with physiological saline solution. The phantom was exposed by using Helmholtz coils from 5 µT to 27 µT with 111 kHz sine-bursts or by using a Qi A13 design wireless charging board (Qi-A13-Board) in two operating modes “power transfer” and “pinging”. With the Helmholtz coils the lowest magnetic flux density at which the performance limit was exceeded is 11 µT. With the Qi-A13-Board in power transfer mode 10.8% and in pinging mode 45.7% (2.2% at 10 cm distance) of the performance limit were reached at maximum. In neither of the scrutinized cases, did the voltage induced by the Qi-A13-Board exceed the performance limits. MDPI 2015-05-27 2015-06 /pmc/articles/PMC4483677/ /pubmed/26024360 http://dx.doi.org/10.3390/ijerph120605886 Text en © 2015 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Seckler, Tobias
Jagielski, Kai
Stunder, Dominik
Assessment of Electromagnetic Interference with Active Cardiovascular Implantable Electronic Devices (CIEDs) Caused by the Qi A13 Design Wireless Charging Board
title Assessment of Electromagnetic Interference with Active Cardiovascular Implantable Electronic Devices (CIEDs) Caused by the Qi A13 Design Wireless Charging Board
title_full Assessment of Electromagnetic Interference with Active Cardiovascular Implantable Electronic Devices (CIEDs) Caused by the Qi A13 Design Wireless Charging Board
title_fullStr Assessment of Electromagnetic Interference with Active Cardiovascular Implantable Electronic Devices (CIEDs) Caused by the Qi A13 Design Wireless Charging Board
title_full_unstemmed Assessment of Electromagnetic Interference with Active Cardiovascular Implantable Electronic Devices (CIEDs) Caused by the Qi A13 Design Wireless Charging Board
title_short Assessment of Electromagnetic Interference with Active Cardiovascular Implantable Electronic Devices (CIEDs) Caused by the Qi A13 Design Wireless Charging Board
title_sort assessment of electromagnetic interference with active cardiovascular implantable electronic devices (cieds) caused by the qi a13 design wireless charging board
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4483677/
https://www.ncbi.nlm.nih.gov/pubmed/26024360
http://dx.doi.org/10.3390/ijerph120605886
work_keys_str_mv AT secklertobias assessmentofelectromagneticinterferencewithactivecardiovascularimplantableelectronicdevicesciedscausedbytheqia13designwirelesschargingboard
AT jagielskikai assessmentofelectromagneticinterferencewithactivecardiovascularimplantableelectronicdevicesciedscausedbytheqia13designwirelesschargingboard
AT stunderdominik assessmentofelectromagneticinterferencewithactivecardiovascularimplantableelectronicdevicesciedscausedbytheqia13designwirelesschargingboard