Cargando…
Implant failure in a proximal femoral fracture treated with dynamic hip screw fixation
Dynamic hip screw fixation is a common orthopaedic procedure and to date, still can cause difficulties to the senior trauma surgeon. We present a case where an extra-capsular fracture of the proximal femur was managed with a dynamic hip screw (DHS) fixation. She proceeded to the operating theatre, w...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4487022/ https://www.ncbi.nlm.nih.gov/pubmed/26136561 http://dx.doi.org/10.1093/jscr/rjv064 |
_version_ | 1782378952866660352 |
---|---|
author | Dabis, John Abdul-Jabar, Hani B. Dabis, Hosam |
author_facet | Dabis, John Abdul-Jabar, Hani B. Dabis, Hosam |
author_sort | Dabis, John |
collection | PubMed |
description | Dynamic hip screw fixation is a common orthopaedic procedure and to date, still can cause difficulties to the senior trauma surgeon. We present a case where an extra-capsular fracture of the proximal femur was managed with a dynamic hip screw (DHS) fixation. She proceeded to the operating theatre, where the fracture was stabilized with a 75-mm DHS and short-barrelled plate. The implant position was checked with intraoperative screening and the position accepted. Following attempted mobilization at 11 days post-operatively, the patient developed a recurrence of her preoperative pain. X-ray showed that the implant screw had separated from the barrel. Later scrutiny of the intraoperative screening films revealed that the barrel and screw were not engaged at the time of surgery. Intraoperative screening films should be carefully checked to ensure congruity of implant components. |
format | Online Article Text |
id | pubmed-4487022 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-44870222015-07-01 Implant failure in a proximal femoral fracture treated with dynamic hip screw fixation Dabis, John Abdul-Jabar, Hani B. Dabis, Hosam J Surg Case Rep Case Reports Dynamic hip screw fixation is a common orthopaedic procedure and to date, still can cause difficulties to the senior trauma surgeon. We present a case where an extra-capsular fracture of the proximal femur was managed with a dynamic hip screw (DHS) fixation. She proceeded to the operating theatre, where the fracture was stabilized with a 75-mm DHS and short-barrelled plate. The implant position was checked with intraoperative screening and the position accepted. Following attempted mobilization at 11 days post-operatively, the patient developed a recurrence of her preoperative pain. X-ray showed that the implant screw had separated from the barrel. Later scrutiny of the intraoperative screening films revealed that the barrel and screw were not engaged at the time of surgery. Intraoperative screening films should be carefully checked to ensure congruity of implant components. Oxford University Press 2015-07-01 /pmc/articles/PMC4487022/ /pubmed/26136561 http://dx.doi.org/10.1093/jscr/rjv064 Text en Published by Oxford University Press and JSCR Publishing Ltd. All rights reserved. © The Author 2015. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Case Reports Dabis, John Abdul-Jabar, Hani B. Dabis, Hosam Implant failure in a proximal femoral fracture treated with dynamic hip screw fixation |
title | Implant failure in a proximal femoral fracture treated with dynamic hip screw fixation |
title_full | Implant failure in a proximal femoral fracture treated with dynamic hip screw fixation |
title_fullStr | Implant failure in a proximal femoral fracture treated with dynamic hip screw fixation |
title_full_unstemmed | Implant failure in a proximal femoral fracture treated with dynamic hip screw fixation |
title_short | Implant failure in a proximal femoral fracture treated with dynamic hip screw fixation |
title_sort | implant failure in a proximal femoral fracture treated with dynamic hip screw fixation |
topic | Case Reports |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4487022/ https://www.ncbi.nlm.nih.gov/pubmed/26136561 http://dx.doi.org/10.1093/jscr/rjv064 |
work_keys_str_mv | AT dabisjohn implantfailureinaproximalfemoralfracturetreatedwithdynamichipscrewfixation AT abduljabarhanib implantfailureinaproximalfemoralfracturetreatedwithdynamichipscrewfixation AT dabishosam implantfailureinaproximalfemoralfracturetreatedwithdynamichipscrewfixation |