Calibration of Traceable Solid Mock (131)I Phantoms Used in an International SPECT Image Quantification Comparison
The International Atomic Energy Agency (IAEA) has organized an international comparison to assess Single Photon Emission Computed Tomography (SPECT) image quantification capabilities in 12 countries. Iodine-131 was chosen as the radionuclide for the comparison because of its wide use around the worl...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
[Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4487311/ https://www.ncbi.nlm.nih.gov/pubmed/26401437 http://dx.doi.org/10.6028/jres.118.017 |
_version_ | 1782378984772730880 |
---|---|
author | Zimmerman, BE Pibida, L King, LE Bergeron, DE Cessna, JT Mille, MM |
author_facet | Zimmerman, BE Pibida, L King, LE Bergeron, DE Cessna, JT Mille, MM |
author_sort | Zimmerman, BE |
collection | PubMed |
description | The International Atomic Energy Agency (IAEA) has organized an international comparison to assess Single Photon Emission Computed Tomography (SPECT) image quantification capabilities in 12 countries. Iodine-131 was chosen as the radionuclide for the comparison because of its wide use around the world, but for logistical reasons solid (133)Ba sources were used as a long-lived surrogate for (131)I. For this study, we designed a set of solid cylindrical sources so that each site could have a set of phantoms (having nominal volumes of 2 mL, 4 mL, 6 mL, and 23 mL) with traceable activity calibrations so that the results could be properly compared. We also developed a technique using two different detection methods for individually calibrating the sources for (133)Ba activity based on a National standard. This methodology allows for the activity calibration of each (133)Ba source with a standard uncertainty on the activity of 1.4 % for the high-level 2-, 4-, and 6-mL sources and 1.7 % for the lower-level 23 mL cylinders. This level of uncertainty allows for these sources to be used for the intended comparison exercise, as well as in other SPECT image quantification studies. |
format | Online Article Text |
id | pubmed-4487311 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology |
record_format | MEDLINE/PubMed |
spelling | pubmed-44873112015-09-23 Calibration of Traceable Solid Mock (131)I Phantoms Used in an International SPECT Image Quantification Comparison Zimmerman, BE Pibida, L King, LE Bergeron, DE Cessna, JT Mille, MM J Res Natl Inst Stand Technol Article The International Atomic Energy Agency (IAEA) has organized an international comparison to assess Single Photon Emission Computed Tomography (SPECT) image quantification capabilities in 12 countries. Iodine-131 was chosen as the radionuclide for the comparison because of its wide use around the world, but for logistical reasons solid (133)Ba sources were used as a long-lived surrogate for (131)I. For this study, we designed a set of solid cylindrical sources so that each site could have a set of phantoms (having nominal volumes of 2 mL, 4 mL, 6 mL, and 23 mL) with traceable activity calibrations so that the results could be properly compared. We also developed a technique using two different detection methods for individually calibrating the sources for (133)Ba activity based on a National standard. This methodology allows for the activity calibration of each (133)Ba source with a standard uncertainty on the activity of 1.4 % for the high-level 2-, 4-, and 6-mL sources and 1.7 % for the lower-level 23 mL cylinders. This level of uncertainty allows for these sources to be used for the intended comparison exercise, as well as in other SPECT image quantification studies. [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 2013-08-15 /pmc/articles/PMC4487311/ /pubmed/26401437 http://dx.doi.org/10.6028/jres.118.017 Text en https://creativecommons.org/publicdomain/zero/1.0/ The Journal of Research of the National Institute of Standards and Technology is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright. |
spellingShingle | Article Zimmerman, BE Pibida, L King, LE Bergeron, DE Cessna, JT Mille, MM Calibration of Traceable Solid Mock (131)I Phantoms Used in an International SPECT Image Quantification Comparison |
title | Calibration of Traceable Solid Mock (131)I Phantoms Used in an International SPECT Image Quantification Comparison |
title_full | Calibration of Traceable Solid Mock (131)I Phantoms Used in an International SPECT Image Quantification Comparison |
title_fullStr | Calibration of Traceable Solid Mock (131)I Phantoms Used in an International SPECT Image Quantification Comparison |
title_full_unstemmed | Calibration of Traceable Solid Mock (131)I Phantoms Used in an International SPECT Image Quantification Comparison |
title_short | Calibration of Traceable Solid Mock (131)I Phantoms Used in an International SPECT Image Quantification Comparison |
title_sort | calibration of traceable solid mock (131)i phantoms used in an international spect image quantification comparison |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4487311/ https://www.ncbi.nlm.nih.gov/pubmed/26401437 http://dx.doi.org/10.6028/jres.118.017 |
work_keys_str_mv | AT zimmermanbe calibrationoftraceablesolidmock131iphantomsusedinaninternationalspectimagequantificationcomparison AT pibidal calibrationoftraceablesolidmock131iphantomsusedinaninternationalspectimagequantificationcomparison AT kingle calibrationoftraceablesolidmock131iphantomsusedinaninternationalspectimagequantificationcomparison AT bergeronde calibrationoftraceablesolidmock131iphantomsusedinaninternationalspectimagequantificationcomparison AT cessnajt calibrationoftraceablesolidmock131iphantomsusedinaninternationalspectimagequantificationcomparison AT millemm calibrationoftraceablesolidmock131iphantomsusedinaninternationalspectimagequantificationcomparison |