Cargando…
Comparisons of the Pentax-AWS, Glidescope, and Macintosh Laryngoscopes for Intubation Performance during Mechanical Chest Compressions in Left Lateral Tilt: A Randomized Simulation Study of Maternal Cardiopulmonary Resuscitation
Purpose. Rapid advanced airway management is important in maternal cardiopulmonary resuscitation (CPR). This study aimed to compare intubation performances among Pentax-AWS (AWS), Glidescope (GVL), and Macintosh laryngoscope (MCL) during mechanical chest compression in 15° and 30° left lateral tilt....
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4487700/ https://www.ncbi.nlm.nih.gov/pubmed/26161426 http://dx.doi.org/10.1155/2015/975649 |
_version_ | 1782379036410904576 |
---|---|
author | Lee, Sanghyun Kim, Wonhee Kang, Hyunggoo Oh, Jaehoon Lim, Tae Ho Lee, Yoonjae Kim, Changsun Cho, Jun Hwi |
author_facet | Lee, Sanghyun Kim, Wonhee Kang, Hyunggoo Oh, Jaehoon Lim, Tae Ho Lee, Yoonjae Kim, Changsun Cho, Jun Hwi |
author_sort | Lee, Sanghyun |
collection | PubMed |
description | Purpose. Rapid advanced airway management is important in maternal cardiopulmonary resuscitation (CPR). This study aimed to compare intubation performances among Pentax-AWS (AWS), Glidescope (GVL), and Macintosh laryngoscope (MCL) during mechanical chest compression in 15° and 30° left lateral tilt. Methods. In 19 emergency physicians, a prospective randomized crossover study was conducted to examine the three laryngoscopes. Primary outcomes were the intubation time and the success rate for intubation. Results. The median intubation time using AWS was shorter than that of GVL and MCL in both tilt degrees. The time to visualize the glottic view in GVL and AWS was significantly lower than that of MCL (all P < 0.05), whereas there was no significant difference between the two video laryngoscopes (in 15° tilt, P = 1; in 30° tilt, P = 0.71). The progression of tracheal tube using AWS was faster than that of MCL and GVL in both degrees (all P < 0.001). Intubations using AWS and GVL showed higher success rate than that of Macintosh laryngoscopes. Conclusions. The AWS could be an appropriate laryngoscope for airway management of pregnant women in tilt CPR considering intubation time and success rate. |
format | Online Article Text |
id | pubmed-4487700 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-44877002015-07-09 Comparisons of the Pentax-AWS, Glidescope, and Macintosh Laryngoscopes for Intubation Performance during Mechanical Chest Compressions in Left Lateral Tilt: A Randomized Simulation Study of Maternal Cardiopulmonary Resuscitation Lee, Sanghyun Kim, Wonhee Kang, Hyunggoo Oh, Jaehoon Lim, Tae Ho Lee, Yoonjae Kim, Changsun Cho, Jun Hwi Biomed Res Int Research Article Purpose. Rapid advanced airway management is important in maternal cardiopulmonary resuscitation (CPR). This study aimed to compare intubation performances among Pentax-AWS (AWS), Glidescope (GVL), and Macintosh laryngoscope (MCL) during mechanical chest compression in 15° and 30° left lateral tilt. Methods. In 19 emergency physicians, a prospective randomized crossover study was conducted to examine the three laryngoscopes. Primary outcomes were the intubation time and the success rate for intubation. Results. The median intubation time using AWS was shorter than that of GVL and MCL in both tilt degrees. The time to visualize the glottic view in GVL and AWS was significantly lower than that of MCL (all P < 0.05), whereas there was no significant difference between the two video laryngoscopes (in 15° tilt, P = 1; in 30° tilt, P = 0.71). The progression of tracheal tube using AWS was faster than that of MCL and GVL in both degrees (all P < 0.001). Intubations using AWS and GVL showed higher success rate than that of Macintosh laryngoscopes. Conclusions. The AWS could be an appropriate laryngoscope for airway management of pregnant women in tilt CPR considering intubation time and success rate. Hindawi Publishing Corporation 2015 2015-06-16 /pmc/articles/PMC4487700/ /pubmed/26161426 http://dx.doi.org/10.1155/2015/975649 Text en Copyright © 2015 Sanghyun Lee et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Lee, Sanghyun Kim, Wonhee Kang, Hyunggoo Oh, Jaehoon Lim, Tae Ho Lee, Yoonjae Kim, Changsun Cho, Jun Hwi Comparisons of the Pentax-AWS, Glidescope, and Macintosh Laryngoscopes for Intubation Performance during Mechanical Chest Compressions in Left Lateral Tilt: A Randomized Simulation Study of Maternal Cardiopulmonary Resuscitation |
title | Comparisons of the Pentax-AWS, Glidescope, and Macintosh Laryngoscopes for Intubation Performance during Mechanical Chest Compressions in Left Lateral Tilt: A Randomized Simulation Study of Maternal Cardiopulmonary Resuscitation |
title_full | Comparisons of the Pentax-AWS, Glidescope, and Macintosh Laryngoscopes for Intubation Performance during Mechanical Chest Compressions in Left Lateral Tilt: A Randomized Simulation Study of Maternal Cardiopulmonary Resuscitation |
title_fullStr | Comparisons of the Pentax-AWS, Glidescope, and Macintosh Laryngoscopes for Intubation Performance during Mechanical Chest Compressions in Left Lateral Tilt: A Randomized Simulation Study of Maternal Cardiopulmonary Resuscitation |
title_full_unstemmed | Comparisons of the Pentax-AWS, Glidescope, and Macintosh Laryngoscopes for Intubation Performance during Mechanical Chest Compressions in Left Lateral Tilt: A Randomized Simulation Study of Maternal Cardiopulmonary Resuscitation |
title_short | Comparisons of the Pentax-AWS, Glidescope, and Macintosh Laryngoscopes for Intubation Performance during Mechanical Chest Compressions in Left Lateral Tilt: A Randomized Simulation Study of Maternal Cardiopulmonary Resuscitation |
title_sort | comparisons of the pentax-aws, glidescope, and macintosh laryngoscopes for intubation performance during mechanical chest compressions in left lateral tilt: a randomized simulation study of maternal cardiopulmonary resuscitation |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4487700/ https://www.ncbi.nlm.nih.gov/pubmed/26161426 http://dx.doi.org/10.1155/2015/975649 |
work_keys_str_mv | AT leesanghyun comparisonsofthepentaxawsglidescopeandmacintoshlaryngoscopesforintubationperformanceduringmechanicalchestcompressionsinleftlateraltiltarandomizedsimulationstudyofmaternalcardiopulmonaryresuscitation AT kimwonhee comparisonsofthepentaxawsglidescopeandmacintoshlaryngoscopesforintubationperformanceduringmechanicalchestcompressionsinleftlateraltiltarandomizedsimulationstudyofmaternalcardiopulmonaryresuscitation AT kanghyunggoo comparisonsofthepentaxawsglidescopeandmacintoshlaryngoscopesforintubationperformanceduringmechanicalchestcompressionsinleftlateraltiltarandomizedsimulationstudyofmaternalcardiopulmonaryresuscitation AT ohjaehoon comparisonsofthepentaxawsglidescopeandmacintoshlaryngoscopesforintubationperformanceduringmechanicalchestcompressionsinleftlateraltiltarandomizedsimulationstudyofmaternalcardiopulmonaryresuscitation AT limtaeho comparisonsofthepentaxawsglidescopeandmacintoshlaryngoscopesforintubationperformanceduringmechanicalchestcompressionsinleftlateraltiltarandomizedsimulationstudyofmaternalcardiopulmonaryresuscitation AT leeyoonjae comparisonsofthepentaxawsglidescopeandmacintoshlaryngoscopesforintubationperformanceduringmechanicalchestcompressionsinleftlateraltiltarandomizedsimulationstudyofmaternalcardiopulmonaryresuscitation AT kimchangsun comparisonsofthepentaxawsglidescopeandmacintoshlaryngoscopesforintubationperformanceduringmechanicalchestcompressionsinleftlateraltiltarandomizedsimulationstudyofmaternalcardiopulmonaryresuscitation AT chojunhwi comparisonsofthepentaxawsglidescopeandmacintoshlaryngoscopesforintubationperformanceduringmechanicalchestcompressionsinleftlateraltiltarandomizedsimulationstudyofmaternalcardiopulmonaryresuscitation |