Cargando…

Improved internal control for molecular diagnosis assays

The two principal determining steps in molecular diagnosis are the amplification and the identification steps. Accuracy of DNA amplification is primarily determined by the annealing sequence of the PCR primer to the analyte DNA. Accuracy for identification is determined either by the annealing regio...

Descripción completa

Detalles Bibliográficos
Autores principales: Vinayagamoorthy, T., Maryanski, Danielle, Vinayagamoorthy, Dilanthi, Hay, Katie S.L., Yo, Jacob, Carter, Mark, Wiegel, Joseph
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4487703/
https://www.ncbi.nlm.nih.gov/pubmed/26150985
http://dx.doi.org/10.1016/j.mex.2015.03.002
_version_ 1782379037085138944
author Vinayagamoorthy, T.
Maryanski, Danielle
Vinayagamoorthy, Dilanthi
Hay, Katie S.L.
Yo, Jacob
Carter, Mark
Wiegel, Joseph
author_facet Vinayagamoorthy, T.
Maryanski, Danielle
Vinayagamoorthy, Dilanthi
Hay, Katie S.L.
Yo, Jacob
Carter, Mark
Wiegel, Joseph
author_sort Vinayagamoorthy, T.
collection PubMed
description The two principal determining steps in molecular diagnosis are the amplification and the identification steps. Accuracy of DNA amplification is primarily determined by the annealing sequence of the PCR primer to the analyte DNA. Accuracy for identification is determined either by the annealing region of a labelled probe for the real time PCR analysis, or the annealing of a sequencing primer for DNA sequencing analysis, that binds to the respective analyte (amplicon). Presently, housekeeping genes (Beta globin, GAPDH) are used in molecular diagnosis to verify that the PCR conditions are optimum, and are thus known as amplification controls [1], [2], [3], [4]. Although these genes have been useful as amplification controls, they lack the true definition of an internal control because the primers and annealing conditions are not identical to the analyte being assayed. This may result in a false negative report [5]. The IC-Code platform technology described here provides a true internal control where the internal control and analyte share identical PCR primers annealing sequences for the amplification step and identical sequencing primer annealing sequence for the identification step. • The analyte and internal control have the same PCR and sequencing annealing sequences. • This method assures for little or no false negatives and false positives due to the method’s design of using identical annealing conditions for the internal control and analyte, and by using DNA sequencing analysis for the identification step of the analyte, respectively. • This method also allows for a set lower limit of detection to be used by varying the amount of internal control used in the assay.
format Online
Article
Text
id pubmed-4487703
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-44877032015-07-06 Improved internal control for molecular diagnosis assays Vinayagamoorthy, T. Maryanski, Danielle Vinayagamoorthy, Dilanthi Hay, Katie S.L. Yo, Jacob Carter, Mark Wiegel, Joseph MethodsX Biochemistry, Genetics and Molecular Biology The two principal determining steps in molecular diagnosis are the amplification and the identification steps. Accuracy of DNA amplification is primarily determined by the annealing sequence of the PCR primer to the analyte DNA. Accuracy for identification is determined either by the annealing region of a labelled probe for the real time PCR analysis, or the annealing of a sequencing primer for DNA sequencing analysis, that binds to the respective analyte (amplicon). Presently, housekeeping genes (Beta globin, GAPDH) are used in molecular diagnosis to verify that the PCR conditions are optimum, and are thus known as amplification controls [1], [2], [3], [4]. Although these genes have been useful as amplification controls, they lack the true definition of an internal control because the primers and annealing conditions are not identical to the analyte being assayed. This may result in a false negative report [5]. The IC-Code platform technology described here provides a true internal control where the internal control and analyte share identical PCR primers annealing sequences for the amplification step and identical sequencing primer annealing sequence for the identification step. • The analyte and internal control have the same PCR and sequencing annealing sequences. • This method assures for little or no false negatives and false positives due to the method’s design of using identical annealing conditions for the internal control and analyte, and by using DNA sequencing analysis for the identification step of the analyte, respectively. • This method also allows for a set lower limit of detection to be used by varying the amount of internal control used in the assay. Elsevier 2015-03-12 /pmc/articles/PMC4487703/ /pubmed/26150985 http://dx.doi.org/10.1016/j.mex.2015.03.002 Text en © 2015 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Biochemistry, Genetics and Molecular Biology
Vinayagamoorthy, T.
Maryanski, Danielle
Vinayagamoorthy, Dilanthi
Hay, Katie S.L.
Yo, Jacob
Carter, Mark
Wiegel, Joseph
Improved internal control for molecular diagnosis assays
title Improved internal control for molecular diagnosis assays
title_full Improved internal control for molecular diagnosis assays
title_fullStr Improved internal control for molecular diagnosis assays
title_full_unstemmed Improved internal control for molecular diagnosis assays
title_short Improved internal control for molecular diagnosis assays
title_sort improved internal control for molecular diagnosis assays
topic Biochemistry, Genetics and Molecular Biology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4487703/
https://www.ncbi.nlm.nih.gov/pubmed/26150985
http://dx.doi.org/10.1016/j.mex.2015.03.002
work_keys_str_mv AT vinayagamoorthyt improvedinternalcontrolformoleculardiagnosisassays
AT maryanskidanielle improvedinternalcontrolformoleculardiagnosisassays
AT vinayagamoorthydilanthi improvedinternalcontrolformoleculardiagnosisassays
AT haykatiesl improvedinternalcontrolformoleculardiagnosisassays
AT yojacob improvedinternalcontrolformoleculardiagnosisassays
AT cartermark improvedinternalcontrolformoleculardiagnosisassays
AT wiegeljoseph improvedinternalcontrolformoleculardiagnosisassays