The Value of Proton Magnetic Resonance Spectroscopy in High-Intensity Focused Ultrasound Treatment of Experimental Liver Cancer()
High-intensity focused ultrasound (HIFU) is a rapidly developing, non-invasive technique for local treatment of solid tumors that produce coagulative tumor necrosis. This study is aimed to investigate the feasibility of proton magnetic resonance spectroscopy (MRS) on early assessing treatment of HIF...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Neoplasia Press
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4487792/ https://www.ncbi.nlm.nih.gov/pubmed/26055173 http://dx.doi.org/10.1016/j.tranon.2015.03.007 |
_version_ | 1782379045411880960 |
---|---|
author | Tang, Zhuo-yue Zhao, Jian-nong Zhong, Wei-jia Luo, Yin-deng Wu, Wei Chen, Wei-juan Dai, Yu-bing |
author_facet | Tang, Zhuo-yue Zhao, Jian-nong Zhong, Wei-jia Luo, Yin-deng Wu, Wei Chen, Wei-juan Dai, Yu-bing |
author_sort | Tang, Zhuo-yue |
collection | PubMed |
description | High-intensity focused ultrasound (HIFU) is a rapidly developing, non-invasive technique for local treatment of solid tumors that produce coagulative tumor necrosis. This study is aimed to investigate the feasibility of proton magnetic resonance spectroscopy (MRS) on early assessing treatment of HIFU ablation in rabbit with VX2 liver tumor. HIFU ablation was performed on normal liver and VX2 tumor in rabbit, and MRS was performed on normal liver and VX2 tumor before and 2 days after 100% HIFU ablation or 80% ablation in tumor volume. Choline (Cho) and choline/lipid (Cho/Lip) ratios between complete and partial HIFU ablation of tumor were compared. Tissues were harvested and sequentially sliced to confirm the necrosis. In normal liver, the Cho value liver was not obviously changed after HIFU (P > .05), but the Cho/Lip ratio was decreased (P < .05). Cho in liver VX2 tumor was much higher than that in normal liver (P < .001). Cho and Cho/Lip ratio were significantly decreased in tumor after complete HIFU ablation and partial HIFU ablation, and the Cho value in complete HIFU tumor ablation did not show any difference from that in normal liver after HIFU (P > .05); however, the Cho value in partial ablation was still higher than that in normal liver before or in tumor after complete HIFU treatment due to the residual part of tumors, and Cho/Lip ratio is lower than that in complete HIFU treatment (P < .001). The changes in MRS parameters were consistent with histopathologic changes of the tumor tissues after treatment. MRS could differentiate the complete tumor necrosis from residual tumor tissue, when combined with magnetic resonance imaging. We conclude that MRS may be applied as an important, non-invasive biomarker for monitoring the thoroughness of HIFU ablation. |
format | Online Article Text |
id | pubmed-4487792 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Neoplasia Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-44877922015-07-07 The Value of Proton Magnetic Resonance Spectroscopy in High-Intensity Focused Ultrasound Treatment of Experimental Liver Cancer() Tang, Zhuo-yue Zhao, Jian-nong Zhong, Wei-jia Luo, Yin-deng Wu, Wei Chen, Wei-juan Dai, Yu-bing Transl Oncol Article High-intensity focused ultrasound (HIFU) is a rapidly developing, non-invasive technique for local treatment of solid tumors that produce coagulative tumor necrosis. This study is aimed to investigate the feasibility of proton magnetic resonance spectroscopy (MRS) on early assessing treatment of HIFU ablation in rabbit with VX2 liver tumor. HIFU ablation was performed on normal liver and VX2 tumor in rabbit, and MRS was performed on normal liver and VX2 tumor before and 2 days after 100% HIFU ablation or 80% ablation in tumor volume. Choline (Cho) and choline/lipid (Cho/Lip) ratios between complete and partial HIFU ablation of tumor were compared. Tissues were harvested and sequentially sliced to confirm the necrosis. In normal liver, the Cho value liver was not obviously changed after HIFU (P > .05), but the Cho/Lip ratio was decreased (P < .05). Cho in liver VX2 tumor was much higher than that in normal liver (P < .001). Cho and Cho/Lip ratio were significantly decreased in tumor after complete HIFU ablation and partial HIFU ablation, and the Cho value in complete HIFU tumor ablation did not show any difference from that in normal liver after HIFU (P > .05); however, the Cho value in partial ablation was still higher than that in normal liver before or in tumor after complete HIFU treatment due to the residual part of tumors, and Cho/Lip ratio is lower than that in complete HIFU treatment (P < .001). The changes in MRS parameters were consistent with histopathologic changes of the tumor tissues after treatment. MRS could differentiate the complete tumor necrosis from residual tumor tissue, when combined with magnetic resonance imaging. We conclude that MRS may be applied as an important, non-invasive biomarker for monitoring the thoroughness of HIFU ablation. Neoplasia Press 2015-06-05 /pmc/articles/PMC4487792/ /pubmed/26055173 http://dx.doi.org/10.1016/j.tranon.2015.03.007 Text en © 2015 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Article Tang, Zhuo-yue Zhao, Jian-nong Zhong, Wei-jia Luo, Yin-deng Wu, Wei Chen, Wei-juan Dai, Yu-bing The Value of Proton Magnetic Resonance Spectroscopy in High-Intensity Focused Ultrasound Treatment of Experimental Liver Cancer() |
title | The Value of Proton Magnetic Resonance Spectroscopy in High-Intensity Focused Ultrasound Treatment of Experimental Liver Cancer() |
title_full | The Value of Proton Magnetic Resonance Spectroscopy in High-Intensity Focused Ultrasound Treatment of Experimental Liver Cancer() |
title_fullStr | The Value of Proton Magnetic Resonance Spectroscopy in High-Intensity Focused Ultrasound Treatment of Experimental Liver Cancer() |
title_full_unstemmed | The Value of Proton Magnetic Resonance Spectroscopy in High-Intensity Focused Ultrasound Treatment of Experimental Liver Cancer() |
title_short | The Value of Proton Magnetic Resonance Spectroscopy in High-Intensity Focused Ultrasound Treatment of Experimental Liver Cancer() |
title_sort | value of proton magnetic resonance spectroscopy in high-intensity focused ultrasound treatment of experimental liver cancer() |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4487792/ https://www.ncbi.nlm.nih.gov/pubmed/26055173 http://dx.doi.org/10.1016/j.tranon.2015.03.007 |
work_keys_str_mv | AT tangzhuoyue thevalueofprotonmagneticresonancespectroscopyinhighintensityfocusedultrasoundtreatmentofexperimentallivercancer AT zhaojiannong thevalueofprotonmagneticresonancespectroscopyinhighintensityfocusedultrasoundtreatmentofexperimentallivercancer AT zhongweijia thevalueofprotonmagneticresonancespectroscopyinhighintensityfocusedultrasoundtreatmentofexperimentallivercancer AT luoyindeng thevalueofprotonmagneticresonancespectroscopyinhighintensityfocusedultrasoundtreatmentofexperimentallivercancer AT wuwei thevalueofprotonmagneticresonancespectroscopyinhighintensityfocusedultrasoundtreatmentofexperimentallivercancer AT chenweijuan thevalueofprotonmagneticresonancespectroscopyinhighintensityfocusedultrasoundtreatmentofexperimentallivercancer AT daiyubing thevalueofprotonmagneticresonancespectroscopyinhighintensityfocusedultrasoundtreatmentofexperimentallivercancer AT tangzhuoyue valueofprotonmagneticresonancespectroscopyinhighintensityfocusedultrasoundtreatmentofexperimentallivercancer AT zhaojiannong valueofprotonmagneticresonancespectroscopyinhighintensityfocusedultrasoundtreatmentofexperimentallivercancer AT zhongweijia valueofprotonmagneticresonancespectroscopyinhighintensityfocusedultrasoundtreatmentofexperimentallivercancer AT luoyindeng valueofprotonmagneticresonancespectroscopyinhighintensityfocusedultrasoundtreatmentofexperimentallivercancer AT wuwei valueofprotonmagneticresonancespectroscopyinhighintensityfocusedultrasoundtreatmentofexperimentallivercancer AT chenweijuan valueofprotonmagneticresonancespectroscopyinhighintensityfocusedultrasoundtreatmentofexperimentallivercancer AT daiyubing valueofprotonmagneticresonancespectroscopyinhighintensityfocusedultrasoundtreatmentofexperimentallivercancer |